Fluke MicroMapper Operation & User’s Manual

Operation & User’s Manual for Fluke MicroMapper Cable Tester, Measuring Instruments (14 pages)

Specifications:

918/918715-micromapper.pdf file (04 Mar 2024)
  • Manufacturer: Fluke
  • Category of Device: Cable Tester, Measuring Instruments
  • Document: MicroMapper, File Type: PDF Operation & User’s Manual
  • Updated: 04-03-2024
  • Count of Pages: 14
Download MicroMapper Manual (14 pages)

Read Fluke MicroMapper PDF Manual Online:

Data: UPD 4th March 2024

Fluke MicroMapper Cable Tester, Measuring Instruments PDF Operation & User’s Manual (Updated: Monday 4th of March 2024 11:18:19 PM)

Rating: 4.9 (rated by 69 users)

Compatible devices: FI-500 FiberInspector Micro, v3000 FC, 433, PM6681, 80i-110s, 1630-2, 05-450, ESA614.

Recommended Documentation:

Text Version of Fluke MicroMapper Cable Tester, Measuring Instruments Manual

(Ocr-Read Summary of Contents, Document's Main Page, UPD: 04 March 2024)
  • Page 1:

    TM

    i

    MICROMAPPER

    LAN Wiremap Checker

    Users Manual

    (English)

    November 2001, Rev. 2, 9/03

    © 2001-2003 Fluke Corporation. All rights reserved.

    All product names are trademarks of their respective companies.

  • Page 2:

    LIMITED WARRANTY AND LIMITATION OF LIABILITY

    Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service. The warranty

    period is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days. This war-

    ranty extends only to the original buyer or end-user customer of a Fluke Networks authorized reseller, and does not apply to disposable

    batteries, cable connector tabs, cable insulation-displacement connectors, or to any product which, in Fluke Networks’ opinion, has been

    misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks war-

    rants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly re-

    corded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.

    Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no

    authority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchased

    through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. Fluke Networks reserves the right to

    invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another

    country.

    Fluke Networks’ warranty obligation is limited, at Fluke Networks’ option, to refund of the purchase price, free of charge repair, or replace-

    ment of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.

    To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then

    send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke Net-

    works assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB

    Destination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal

    condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair

    costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation

    prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

    THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING

    BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL

    NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING

    FROM ANY CAUSE OR THEORY.

    Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or conse-

    quential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held

    invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforce-

    ability of any other provision.

    6/01 Fluke Networks

    PO Box 777

    Everett, WA 98206-0777

    USA

  • Page 3:

    i

    Table of Contents

    Title Page

    Introduction ....................................................................................................................1

    Features .......................................................................................................................... 2

    M

    ICROMAPPER Kit Content ................................................................................................ 2

    Registration..................................................................................................................... 2

    Safety Information........................................................................................................... 3

    Contacting Fluke Networks.............................................................................................. 3

    M

    ICROMAPPER Controls and LEDs ...................................................................................... 4

    Battery ............................................................................................................................ 5

    MICROMAPPER’s Toner Operation....................................................................................... 5

    MicroMapper Tests.......................................................................................................... 6

    Fault Status ..................................................................................................................... 7

    Technical Specifications ................................................................................................... 9

  • Page 4:

    MicroMapper

    Users Manual

    ii

  • Page 5:

    1

    MICROMAPPER™

    Introduction

    Congratulations on your purchase of the

    M

    ICROMAPPER network cable tester!

    The M

    ICROMAPPER is a hand-held cable tester that

    enables network professionals to quickly and easily

    verify the integrity of Ethernet twisted pair cables. In

    one step, the M

    ICROMAPPER will test twisted pair

    cabling for opens, shorts, reversed, crossed, and split

    pairs. Simply slide the switch to the Cable position,

    press the

    (TEST) button and the M

    ICROMAPPER will

    automatically scan for any existing faults in your cable.

    The specially designed remote unit is provided for

    one-person testing of installed cabling. The tone

    generator function can be used with the MicroProbe

    cable tracer to trace cables and locate cables hidden in

    ceilings, walls, floors, and bundles.

  • Page 6:

    MicroMapper

    User’s Manual

    2

    Features

    • Tests for wiring faults and detects opens, shorts,

    crossed, reversed, and split pairs. (Split pair fault

    detection requires a minimum cable length of

    15.75" (40cm))

    • Verifies shield integrity

    • M

    ICROMAPPER’s Remote Identifier enables one

    person to test installed cabling

    • Easy to read fault display and high speed testing

    • Generation of two tones for tracing cables and

    locating hidden cables

    • Debug-mode for detailed fault identification

    results

    • Auto-sleep mode to decrease power consumption

    MICROMAPPER Kit Content

    Your MICROMAPPER kit contains the following:

    • 1 M

    ICROMAPPER network cable tester

    • 1 M

    ICROMAPPER remote

    • Patch cord

    • Quick Reference Guide

    • Product Manuals CD

    Registration

    Registering your product with Fluke Networks gives

    you access to valuable information on product updates,

    troubleshooting tips, and other support services.

    To register, fill out the online registration form on the

    Fluke Networks website at

    www.flukenetworks.com/registration. If you do not

    have Internet access, print the registration form from

    the CD included with the product. Fill out the form,

    then mail or fax it to the appropriate address for your

    country.

  • Page 7:

    MicroMapper™

    Safety Information

    3

    Safety Information

    WWarnings

    Do not connect MICROMAPPER to a live

    circuit as it may damage the unit.

    Do not open the unit or attempt to repair

    in case of malfunction. Please send it

    back to your distributor for repair or

    replacement.

    Caution

    Strong radio frequency fields may cause

    inaccurate readings.

    Do not drop or get the unit wet. Do not

    expose MICROMAPPER to extreme humidity

    or direct sunlight.

    Contacting Fluke Networks

    www.flukenetworks.com

    [email protected]

    +1-425-446-4519

    • Australia: 61 (2) 8850-3333 or 61 3 9329 0244

    • Beijing: 86 (10) 6512-3435

    • Brazil: 11 3044 1277

    • Canada: 1-800-363-5853

    • Europe: +44 1923 281 300

    • Hong Kong: 852 2721-3228

    • Japan: +81-3-3434-0181

    • Korea: 82 2 539-6311

    • Singapore: +65-6738-5655

    • Taiwan: (886) 2-227-83199

    • USA: 1-800-283-5853

    Visit our website at www.flukenetworks.com for a

    complete list of phone numbers.

  • Page 8:

    MicroMapper

    User’s Manual

    4

    MICROMAPPER Controls and LEDs

    1

    -

    23

    -

    64

    -

    57

    -

    8 SHIELD

    SHORT

    TONER

    TEST

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

    REMOTE

    M

    ICRO

    M

    APPER

    atx02f.eps

    Figure 1. MICROMAPPER Network Cable Tester

    Table 1. M

    ICROMAPPER Controls and LEDs

    Item

    Number

    Description

    A Pair and Shield Indicator LEDs

    B Toner LED

    C TEST button

    D REMOTE Adapter with RJ45 Jack

    E RJ45 Jack

    F Off/Cable/Toner Switch

    G Fault LEDs

    H Low Battery LED

  • Page 9:

    MicroMapper™

    Battery

    5

    Battery

    MICROMAPPER requires four 1.5 AAA batteries. IEC :

    LR03. Others : AAA, E92, 4003; JIS : AM 4 ; ANSI : 24A;

    1.5 Volt (nominal).

    atx03s.bmp

    The Battery LED will light up when MICROMAPPER

    detects a low battery condition. Using MICROMAPPER

    with a low battery may affect the test accuracy. If

    M

    ICROMAPPER is stored for more than a month, the

    battery should be removed.

    MICROMAPPER’s Toner Operation

    1. Slide the switch on the right side of MICROMAPPER

    to the Toner position.

    2. Connect the cable to the M

    ICROMAPPER’s RJ45 jack.

    (To send a tone into a patch panel, connect one

    end of the included patch cord to the

    M

    ICROMAPPER’s RJ45 jack and the other end to a

    jack on the panel.)

    3. To generate tone 1, press and quickly release the

    (TEST) button.

    4. To generate tone 2, press and hold the

    (TEST)

    button for two seconds.

    5. Use the M

    ICROPROBE to trace the connected cable.

    The signal reception is strongest near the cable

    under test.

    6. Slide the switch on the right side to the Off

    position to discontinue the tone. (Always power

    the unit off to prevent battery drain.)

  • Page 10:

    MicroMapper

    User’s Manual

    6

    MICROMAPPER Tests

    1. Slide the switch on the right side to the Cable

    position to turn M

    ICROMAPPER on.

    2. Connect one end of the cable to be tested to the

    M

    ICROMAPPER’s RJ45 jack.

    3. Connect the other end of the cable to the

    M

    ICROMAPPEr Remote’s RJ45 jack.

    4. Press (TEST) to view the results.

    5. The horizontal LEDs indicate the cable’s integrity

    status.

    • Green: Pair or Shield is good

    • Green flashing: Pair or Shield is faulty

    • No light: Pair is open or cable is not shielded

    The vertical LEDs indicate the wiring faults and a

    low battery status. Wiring faults are: SHORT,

    REVERSED, MISWIRE, SPLIT PAIRS.

    6. To find out a fault on a specific pair, use

    M

    ICROMAPPER’s diagnostic feature.

    7. Press and hold

    (TEST) for more than 2 seconds.

    M

    ICROMAPPER will scan each pair and the shield

    pausing and flashing each green LED separately. If

    a faulty pair is detected, the corresponding fault

    status will blink in red.

    Note

    Push the Remote Terminator onto the

    MicroMapper until it snaps into position. This

    configuration allows you to conveniently test

    patch cables.

  • Page 11:

    MicroMapper™

    Fault Status

    7

    Fault Status

    SHORT

    TEST

    TONER

    SHORT

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

    1-2 3-6 4-5 7-8

    SHIELD

    1

    2

    3

    6

    4

    5

    7

    8

    1

    2

    3

    6

    4

    5

    7

    8

    SS

    OPEN

    1

    2

    3

    6

    4

    5

    7

    8

    1

    2

    3

    6

    4

    5

    7

    8

    SS

    1-2 3-6 4-5 7-8

    SHIELD

    TEST

    TONER

    SHORT

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

  • Page 12:

    MicroMapper

    User’s Manual

    8

    REVERSED

    1

    2

    3

    6

    4

    5

    7

    8

    S

    1

    2

    3

    6

    4

    5

    7

    8

    S

    TEST

    TONER

    SHORT

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

    1-2 3-6 4-5 7-8

    SHIELD

    MIS-WIRE

    TEST

    TONER

    SHORT

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

    1-2 3-6 4-5 7-8

    SHIELD

    1

    2

    3

    6

    4

    5

    7

    8

    S

    1

    2

    3

    6

    4

    5

    7

    8

    S

    SPLIT PAIR

    TEST

    TONER

    SHORT

    REVERSED

    MISWIRE

    SPLIT PAIRS

    LOW BATTERY

    1-2 3-6 4-5 7-8

    SHIELD

    1

    2

    3

    6

    4

    5

    7

    8

    S

    1

    2

    3

    6

    4

    5

    7

    8

    S

  • Page 13:

    MicroMapper™

    9

    Technical Specifications

    Connectors

    M

    ICROMAPPER main unit: RJ45 jack

    Remote Identifier: RJ 45 jack

    Pairs tested

    1-2, 3-6, 4-5, 7-8, and shield

    LED Display

    Horizontal: 5 green LEDs for pairs and shield

    display

    (1 - 2, 3 - 6, 4 - 5, 7 - 8, and SHIELD)

    Vertical: 6 red LEDs (TONER, SHORT, REVERSED,

    MISWIRE, SPLIT PAIRS, and LOW BATTERY)

    Cables test limit

    Minimum: 15.75" (40cm); Maximum: 656’ (200 m)

    Power

    IEC 86-1 (1996-07) --- Primary Batteries - General

    IEC 60086-2 (1997-07) --- Primary Batteries -

    Specification Sheets

    M

    ICROMAPPER: requires four 1.5 AAA batteries. IEC :

    LR03; Others : AAA, E92, 4003; JIS : AM 4 ; ANSI :

    24A; 1.5 Volt (nominal)

    Remote Identifier: No battery required

    Dimensions

    M

    ICROMAPPER: 4.92" x 2.05" x 1.54" 1

    125 mm x 52 mm x 39 mm

    Remote Identifier: 1.87" x 1.12" x 0.87"

    47mm x 28mm x 22mm

    Weight

    M

    ICROMAPPER with Remote Identifier: 125 g

  • Page 14:

    10

    MicroMapper

    Users Manual

DOC-2317dd4f:

Recommended:

EL2899, ONE WELRV1, SR90, DCM561, ICY BOX IB-WF200HD, B1861N2GB, Stacked Washers and Dryers, PST-4
Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Graco
Series D
20 29/02
2 Tecfluid
Series LT
48 21/05
3 Auto Test
AutoLight
7 07/05
4 SATA
LPS R 2000
100 09/03
5 auna
RQ-132
13 17/12
6 Campbell
LP02
28 25/12
7 HEIDENHAIN
ND 280 - GUIDE
12 0.84 Mb 18/04
8 LANDTEC
GEM5000
70 29/05
9 Mastech
MS2600
10 02/03
10 Omega
DFG207
12 03/05
11 AMERITECH
AM8a
152 21/02
12 TESTO
6681
85 28/02
13 Lincoln
SSV-E
24 16/12
14 PCE Instruments
PCE-PB-N series
14 12/04
15 AEMC
MN373
4 11/06
16 AUTOMATION24
PMS-714
8 12/01
17 VorTek
SonoPro S34 Series
83 24/05
18 Kobold
NUS-4x04
40 26/03
19 Vega
ASV-1
24 23/12
20 MFJ
MFJ-869
20 24/12
Popular Right Now:
# Brand Model Document (PDF) Pages Size Check Date
1 Fortinet
FortiFone FON-C71
16 06.01.
2 Cembre
ECW-H3D
20 11.02.
3 ProActiv
SPEEDY
16 26.03.
4 Bianco di Puro
Patto Pro
68 09.01.
5 Hobbico
Nexstar select
28 15.04.
6 Fox
M Series
2 26.01.
7 Bradley
WF2605
28 0.48 Mb 05.02.
8 Topcom
BUTLER 4570
28 1.07 Mb 10.02.
9 National Instruments
MON-10467
33 27.02.
10 Microlife
PT 200
45 07.02.
11 SIMAG
SPR 80
4 25.03.
12 TV Star
TD9v
46 20.02.
13 Hasselblad
A12
2 0.3 Mb 10.05.
14 Gallien-Krueger
210RBH
4 0.33 Mb 15.05.
15 UE
TX200H
6 25.12.
16 KUULAIRE
KA40
16 20.04.
17 Minolta
REGIUS CS-2
3 21.12.
18 Canon
imageFORMULA CR-L1
48 28.01.
19 Telio
obihai
8 20.05.
20 TRENDnet
TV-IP572W
43 5.24 Mb 10.05.
21 Oldfield
OD’78
4 19.01.
22 OSO
SOLARCYL
16 14.02.
23 NEC
Pinwriter P6
10 14.06.
24 Cisco
ACE-4710-1F-K9
22 0.31 Mb 28.04.
25 Sunbeam
FG5600
24 18.03.
26 Kitchen Living
EPM-250
15 09.12.
Operating Impressions, Questions and Answers: