JRC JMA-3300 Series Installation Manual

Installation Manual for JRC JMA-3300 Series Marine Radar, Radar (204 pages)

Specifications:

1304/1304914-jma3300_series.pdf file (20 Feb 2024)
  • Manufacturer: JRC
  • Category of Device: Marine Radar, Radar
  • Document: JMA-3300 Series, File Type: PDF Installation Manual
  • Updated: 20-02-2024
  • Count of Pages: 204
Download JMA-3300 Series Manual (204 pages)

Read Document Online:

Data: UPD 20th February 2024

JRC JMA-3300 Series Marine Radar, Radar PDF Installation Manual (Updated: Tuesday 20th of February 2024 03:55:53 PM)

Rating: 4.6 (rated by 6 users)

Compatible devices: JMA-932B-SA, JMA-7133-SA, JMA-1030 Series, JUE-250, JMR-5410-6XH, Radar 3000, JMA-9132-SA, JMA-5912-6.

Recommended Documentation:

Text Version of JRC JMA-3300 Series Manual (Summary of Contents)

(Ocr-Read of the JRC JMA-3300 Series Document (Main Content), UPD: 20 February 2024)
  • 12, JRC JMA-3300 Series Chapter 2 INSTALLATION OF THE SCANNER 2.1 SELECTING THE INSTALLATION POSITION 2-4 Fig. 2.1-4 Scanner and the surrounding structural objects Vertical beam width of X-band: Approx. 20° (+/-10.0° when the height of the radiating section is 0°) When installing two scanners, provide a height difference so that those two scanners do …

  • 109, Chapter 4 ADJUST MENU SETTINGS 4.8 COM PORT SETTING 4-43 4 NSTALLATION MANUAL  Setting TX Target Sets the target to which the TTM, TLL, TTD and TLB sentences are output. 1 Open Target Information TX - TX Target . "TX Target" menu appears. Sets the TX Target.  TTM Distance Accuracy Sets the number of decimal places…

  • 80, JRC JMA-3300 Series Chapter 4 ADJUST MENU SETTINGS 4.3 RADAR ECHO 4-14  STC Slope Correction Sets the slope of the STC curve. 1 Open Sea - STC Slope Correction . "STC Slope Correction" menu appears. Press the cursor key or turn the [MULTI] control to set the slope correction value. The slope correction value can be set between 0.0 and 2.…

  • 177, APPENDIX APPENDIX-3 APPENDIX NSTALLATION MANUAL Fig. A3 Exterior Drawing of Scanner Unit, Type NKE-2062/HS …

  • 39, JRC JMA-3300 Series Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.5 CONNECTING TO THE JRC'S GPS RECEIVER 3-9 3 NSTALLATION MANUAL  Setting of JMA-3300 Basically, no setting is required. No special setting is required for the use. However, to change the setting for selecting or restricting the sentences to be received, change the setting a…

  • 116, JRC JMA-3300 Series Chapter 4 ADJUST MENU SETTINGS 4.9 GPS 4-50  Position Inputs the approximate latitude and longitude of the own ship to acquire initial positioning quickly. 1 Open GPS Adjust - Position . "Position" menu appears. Press the cursor key or turn the [MULTI] control to set the latitude and longitude. After setting, open …

  • 81, Chapter 4 ADJUST MENU SETTINGS 4.3 RADAR ECHO 4-15 4 NSTALLATION MANUAL  FTC Curve Select Switches the FTC Curve. 1 Open Sea - FTC Curve Select . "FTC Curve Select" menu appears. Sea and rivers can be set.  FTC Slope Correction Sets the slope of the FTC curve. 1 Open Sea - FTC Slo…

  • 140, JRC JMA-3300 Series Chapter 4 ADJUST MENU SETTINGS 4.11 MAINTENANCE 4-74  Motor Rotating Time Initializes the scanner motor rotating time. Initialize the motor rotating time as shown below when motor is replaced. 1 Open Scanner Time Clear - Motor Time Clear . Yes : Clears the motor rotating time. No : Does not clear. W…

  • 164, JRC JMA-3300 Series Chapter 4 ADJUST MENU SETTINGS 4.14 ERROR ALARM MASK 4-98 4.14 ERROR ALARM MASK Sets the error alarm.  "Error Alarm Mask" operations 1 Open Error Alarm Mask from the Adjust Menu. "Error Alarm Mask" menu appears. 4.14.1 SCANNER Sets the error alarm of scanner.  "Scanner" operations…

  • 119, Chapter 4 ADJUST MENU SETTINGS 4.9 GPS 4-53 4 NSTALLATION MANUAL  Beacon Frequency Setting Sets the Beacon frequency. This setting is enabled when beacon "Select" is set to "2. Manual". 1 Open Beacon Setting - Frequency . "Frequency" menu appears. Can set the Beacon frequency. After setting, open &…

  • 88, JRC JMA-3300 Series Chapter 4 ADJUST MENU SETTINGS 4.6 SCANNER 4-22 4.6.3 STAGGER TRIGGER Turns on/off the interference reduction function controlled by the transmission repetition frequency control of the transmitter. This function is effective when radar interference does not go away. Reference: This setting cannot be performed…

  • 56, JRC JMA-3300 Series Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.8 CONNECTING TO THE GYRO AND ELECTROMAGNETIC LOG (NSK UNIT SETTING) 3-26  Baud Rate Setting When setting the gyro in "● Heading Equipment Setting", the setting of the baud rate is not required.  Connecting to External Buzzers When connecting an extern…

  • 55, JRC JMA-3300 Series Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.8 CONNECTING TO THE GYRO AND ELECTROMAGNETIC LOG (NSK UNIT SETTING) 3-25 3 NSTALLATION MANUAL S5 SETTING TABLE 12345678 STEP ON SYNC OFF ON ON OFF ON ON OFF OFF OFF ON OFF ON OFF N.C. any ON ON OFF ON ON OFF OFF OFF 200P/90× 400P/180× 800P/360× NOR RATIO 36× 90× 180× …

  • 63, JRC JMA-3300 Series Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.11 CONNECTING CONTACT SIGNALS TO EXTERNAL BUZZERS/EXTERNAL DEVICES 3-33 3 NSTALLATION MANUAL Using jumper TB2, set whether the buzzer contact is opened or closed at the normal condition according to the utilization condition. Set the output with TB2 on the I/F circuit CMH-2235. Nor…

  • 31, JRC JMA-3300 Series Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.1 SELECTING THE INSTALLATION POSITION 3-1 3 NSTALLATION MANUAL Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.1 SELECTING THE INSTALLATION POSITION Select the display unit installation position by taking into consideration the following.  Install the display unit so that the user can easily condu…

  • 103, Chapter 4 ADJUST MENU SETTINGS 4.8 COM PORT SETTING 4-37 4 NSTALLATION MANUAL  Baud Rate Setting 1 Open COM Port Setting - Baud Rate . "Baud Rate" menu appears. "Gyro/Compass" menu appears. Sets the baud rate. Operate the same way for the other settings. 4.8.2 RX SENTENCE Set signal sentence…

  • 52, Chapter 3 INSTALLATION OF THE DISPLAY UNIT 3.8 CONNECTING TO THE GYRO AND ELECTROMAGNETIC LOG (NSK UNIT SETTING) 3-22  Setting and adjustment of the NSK unit The NSK Unit of the radar equipment is designed to be compatible with almost all types of gyro compass by switch operation (For the step motor type, 20 VDC to 170 V…

Similar Searches:
  • JRC JMA-3300 Series User Manual
  • JRC JMA-3300 Series User Guide
  • JRC JMA-3300 Series PDF Manual
  • JRC JMA-3300 Series Owner's Manuals

DOC-b0920bb3:

Recommended:
MTP750, DG-HR1060MS, Performance series, SF51

PinpointR, GMR 18 XHD, Expanse XP20, Profi Bus Levelflex M FMP40, Levelflex M FMP43
  • UM-003-A OPS243-A User Manual 1 OmniPreSense Corporation UM-003 OPS243-A User Manual OmniPreSense OPS243-A short range radar sensor has an easy to use API to control the output of the sensor. Simple commands can be used to configure the operation and output information provided by the sensor. Default settings are noted below. Upon powering on the module, the default settings are used. Installation Instructions The OP ...

    Model & Doc Type: OPS243-A 22

  • XA00690F-A/00/A3/02.1371224238Safety InstructionsMicropilotFMR54/56/57PROFIBUS PA, FOUNDATION FieldbusATEX: II 1 D Ex ta IIIC T500 xx°C DaII 1/2 D Ex ta IIIC Txx°C Da/DbIECEx: Ex ta IIIC T500 xx°C DaEx ta IIIC Txx°C Da/Db0de - Dokument: XA00690F-ASicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche gemäß Richtlinie 94/9/EG (ATEX) und IEC 60079-0  ä 5en - Document: XA00690F-ASafety instructions for electrical apparatus for explosion-hazardous ...

    Model & Doc Type: Micropilot FMR54 28

  • INSTRUCTIONINSTRUCTIONMANUALMANUALISO 9001, ISO 14001 CertifiedJUL. 2017 Edition 3CODE No.7ZPRD0767Not use the asbestos For further information,contact:URL Head office : http://www.jrc.co.jp/eng/Marine Service Department 1-7-32 Tatsumi, Koto-ku, Tokyo 135-0053, Japan           : [email protected]           : +81-50-3786-9201e-mailOne-call RIVER RADARRIVER RADAREQ ...

    Model & Doc Type: JMA-610 172

  • ADAR1000-EVALZ User Guide UG-1283 One Technology Way • P. O. Box 9106 • Norwood, MA 02062-9106, U.S.A. • Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com Evaluating the ADAR1000 8 GHz to 16 GHz, 4-Channel, X Band and Ku Band Beamformer PLEASE SEE THE LAST PAGE FOR AN IMPORTANT WARNING AND LEGAL TERMS AND CONDITIONS. Rev. 0 | Page 1 of 18 FEATURES Based on the ADAR1000 4-channel beamformer core chip ...

    Model & Doc Type: ADAR1000-EVALZ 18

Additional Information:

# Brand Model Document Type/File Pages File Size Last Checked
1 Kustom
FALCON
25 19/02
2 YSI
NILE
4 04/12
3 RADAC
WaveGuide 5 Direction
48 12/01
4 Simrad
R5000
4 15/02
5 Rosemount
5600 Series
210 19/12
6 Endress+Hauser
Micropilot FMR51
166 10/01
7 Vega
VEGAPULS 69
84 06/09
8 JRC
JMA-933B
168 22/01
9 Endress+Hauser
Micropilot FMR54
28 08/10
10 DITEC
PasM242
10 28/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Airlink101
AWLL5026
33 1.56 Mb 04.11.2023
2 ATD Tools
ATD7341
8 12.11.2023
3 Sony
SMP-NX20
1 0.34 Mb 07.10.2023
4 Ariston
LFF 8H54
52 15.12.2023
5 BenQ
FP537s
32 3.77 Mb 13.02.2024
6 Oki
LP470w
78 27.01.2024
7 FHF
FernTel 3 Z2
8 07.09.2023
8 Rosewill
RU101
2 0.24 Mb 02.12.2023
9 DT Research
DT395CR
4 30.12.2023
10 Jacobsen
AR-522
111 16.10.2023

Operating Impressions, Questions and Answers: