JUMO dTRON 304 Operating Instructions Manual

Operating Instructions Manual for JUMO dTRON 304 Controller (24 pages)

Specifications:

1411/1411801-dtron_304.pdf file (21 Sep 2023)
  • Manufacturer: JUMO
  • Category of Device: Controller
  • Document: dTRON 304, File Type: PDF Operating Instructions Manual
  • Updated: 21-09-2023
  • Count of Pages: 24
Download dTRON 304 Manual (24 pages)

Read JUMO dTRON 304 Document Online:

Data: UPD 21st September 2023

JUMO dTRON 304 Controller PDF Operating Instructions Manual (Updated: Thursday 21st of September 2023 04:23:01 PM)

Rating: 4.9 (rated by 66 users)

Compatible devices: diraTRON 104, DICON touch, AQUIS 500 pH, diraTRON Series, 709062/8-01-50, dTRANS CR 02, Quantrol LC200, IMAGO 500.

Recommended Documentation:

Text Version of JUMO dTRON 304 Operating Instructions Manual (Summary of Contents)

(Ocr-Read of the JUMO dTRON 304 Document (Main Content), UPD: 21 September 2023)
  • 1, J dTRON 304 J dTRON 308 J dTRON 316 Compact Controller with program function B 70.3041.1 Operating Instructions 06.05 JUMO dTRON 316 JUMO dTRON 308 JUMO dTRON 308 JUMO dTRON 304 …

  • 3, JUMO dTRON 304 Contents 1 Preface ............................................................... 3 1.1 Scope of delivery ..................................................................... 3 2 Identifying the instrument version ................... 4 3 Mounting ............................................................ …

  • 4, JUMO dTRON 304 1 Preface 3 1 Preface 1.1 Scope of delivery - 1 controller - seal - mounting brackets - brief operating instructions - 1 CD with compre hensive operating instructions and setup program as a demo version H These brief operating instructions only cover those actions that are essential for starting up the …

  • 5, 2 Identifying the instrument version 4 2 Identifying the instrument version Meaning of the number code on the nameplate: Basic type 703041 JUMO dTRON 316, 48 mm x 48 mm format incl. 1 analog input, 2 relay outputs and 2 binary inputs or 2 logic outputs 703042 JUMO dTRON 308, 48 mm x 96 mm format (portrait …

  • 6, JUMO dTRON 304 3 Mounting 5 3 Mounting 3.1 Preparation 3.2 Fitting in position, Type 703042/43/44 h Fit the seal that is supplied onto the instrument body. h Insert the controller from the front into the panel cut-out. h From behind the panel, slide the mounting brackets into the guides on the sides of the housing. The fla…

  • 7, 4 Electrical connection 6 4 Electrical connection 4.1 Connection diagram for Type 703041 5 6 7 8 6 7 8 1 1 2 3 4 1 2 2 3 4 8 3 4 6 7 3 5 L1(L+) N(L-) …

  • 8, JUMO dTRON 304 4 Electrical connection 7 4.2 Connection diagram for Type 703042/43/44 1 1 2 3 4 2 1 2 3 4 5 6 7 8 6 7 8 9 10 9 10 11 12 3 4 L1(L+) 5 6 8 9 11 12 13 15 16 17 N(L+) …

  • 9, 5 Displays and keys 8 5 Displays and keys Different values can also be visualized on the display. v see the comprehensive operating manual on the CD (1) 7-segment display (factory setting: process value) four-digit, red, decimal place is configurable (automatic adjustment on display overflow) (2) Active setpoint (…

  • 10, 6 Operation 9 6 Operation 6.1 Level concept The diagram below shows the three instrument levels. H Time-out If no key is pressed for 30 sec, the instrument returns to normal display. …

  • 11, 6 Operation 10 6.2 Level inhibit The access to the individual levels can be inhibited by entering a code number. h Press P and D simultaneously for >5 sec to enter the code. h Alter code with P (display blinks) h Enter code with I and D h Return to normal display with X or automatically after approx. 30 sec 6.3 …

  • 12, 6 Operation 11 6.4 Entering times When entering times (e.g. time of timer), the time unit is shown in addition. The highest time unit of the display is shown for the unit. For example, if “h” is shown for the hour, then the time format for the value is hh:mm. h Select parameter with I or D h Change to t…

  • 13, 6 Operation 12 6.5 Operation of the fixed-setpoint controller H The fixed-setpoint controller will only function if - the fixed-setpoint controller function has been configured ( Fnct = 0) h Alter the present setpoint with I and D The value is accepted automatically. The controller output appears in the …

  • 14, JUMO dTRON 304 6 Operation 13 6.6 Operation of the program controller The program is canceled in the event of a power failure. H The program controller will only function if - the program controller function has been configured ( Fnct = 1 ...4) - the program setpoints (SPP1 ... SPP8) and segment times (tP 1 ... tP …

  • 15, 7 Operator level “OPr” 14 7 Operator level “OPr” Process data ProC User data USEr (through the setup program only) Any parameter (up to eight) can be displayed and edited here by using the setup program. Program data Pro (only with program controller/generator) A program with up to eight se…

  • 16, JUMO dTRON 304 8 Parameter level “PArA” 15 8 Parameter level “PArA” Two parameter sets, PAr1 und PAr2, can be stored. Parameter Symbol Value range Factory setting Proportional band 1 a a. with Pb1/2=0, the controller structure is not effective; depending on the display configuration, these values are shown wi…

  • 17, 9 Configuration level “ConF” 16 9 Configuration level “ConF” Depending on the equipment level of the instrument, individual parameters or groups of parameters are switched out of display. Analog selector With some parameters, you can choose from a series of analog signals. The list below g…

  • 18, JUMO dTRON 304 9 Configuration level “ConF” 17 r In12 Analog input 1 and 2 general r 9.2 Controller “Cntr” 9.3 Generator “Pro” Linearization 0 Linear 10 Thermocouple type U 1 Pt100 11 Thermocouple type L 2 Pt500 12 Thermocouple type K 3 Pt1000 13 Thermocouple type S 4 KTY11-6 14 Thermocouple type R 5 The…

  • 19, 9 Configuration level “ConF” 18 9.4 Outputs “OutP” Numbering of the outputs Standard: Relay 1 = output 1; relay 2 = output 2; logic output 1 = output 3; logic output 2 = output 4 r Analog outputs OutA r Output 5 — 7 Out5...Out7 r Slot Plug-in board with 1 analog output Plug-in board with …

  • 20, 9 Configuration level “ConF” 19 r Binary outputs OutL r Output 1 — 10 Out1 ... Out0 r 9.5 Display “diSP” r Function 0 no function 16 Limit comparator 4 1 Controller output 1 17 Control contact 1 2 Controller output 2 18 Control contact 2 3 - not used 19 Control contact 3 4 - not used 20 Control…

  • 21, 10 Autotuning 20 10 Autotuning The autotuning facility can be used to automatically adapt the controller parameters to the process. The autotuning function determines the controller parameters for a PID controller or, if dt=0 is set, for a PI controller in a closed control loop. h Start with I and D (…

  • 22, JUMO dTRON 304 11 Alarms 21 11 Alarms Overrange / underrange covers the following events: - probe break / short-circuit - measurement is outside the controllable range for the probe connected -display overflow Displaying the software version h Display version with P and I (press simultaneously). Display Cause C…

  • 24, JUMO dTRON 304 JUMO GmbH & Co. KG Street adress: Moltkestraße 13 - 31 36039 Fulda, Germany Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Ba…

DOC-e380a984:

Recommended:
4380, 336FR, 103.311, ZR-1N

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Lattice Semiconductor
MachXO2
24 24/12
2 GE
F35
570 07/02
3 IAI
X-SEL
535 26/01
4 Siemens
SIMATIC ET 200SP
271 06/11
5 Watlow
PM LEGACY PM3
30 03/01
6 McIntosh
C1100
36 03/02
7 Walchem
WDIS Series
35 14/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Sony
XR-4900
36 09.02.2024
2 Whistler
XTR-130
9 0.15 Mb 13.02.2024
3 Cooper Lighting
Halo LZR51017
3 0.44 Mb 08.11.2023
4 OSD Audio
MKW-850
8 10.01.2024
5 IKEA
IH3302WQ0
24 01.01.2024
6 DAEWOO ELECTRONICS
DLN-15D3SHS
26 27.09.2023
7 Brocade Communications Systems
SN3000B
966 2.86 Mb 01.09.2023
Operating Impressions, Questions and Answers: