VDW CONNECT Locate Apex Locator Getting Started Manual

VDW CONNECT Locate Apex Locator Dental equipment Manual (20 pages)

Specifications:

1344/1344364-connect_locate_apex_locator.pdf file (14 Apr 2023)
  • Manufacturer: VDW
  • Category of Device: Dental equipment
  • Document: CONNECT Locate Apex Locator Getting Started Manual, File Type: PDF
  • Updated: 14-04-2023
  • Count of Pages: 20
Download CONNECT Locate Apex Locator Manual (20 pages)

VDW CONNECT Locate Apex Locator: Read Manual Online

  • VDW CONNECT Locate Apex Locator #1
  • VDW CONNECT Locate Apex Locator #2
  • VDW CONNECT Locate Apex Locator #3
  • VDW CONNECT Locate Apex Locator #4
  • VDW CONNECT Locate Apex Locator #5
  • VDW CONNECT Locate Apex Locator #6
  • VDW CONNECT Locate Apex Locator #7
  • VDW CONNECT Locate Apex Locator #8
Accompanying Data:

VDW CONNECT Locate Apex Locator Dental equipment PDF Getting Started Manual (Updated: Friday 14th of April 2023 11:19:12 PM)

Rating: 4.7 (rated by 76 users)

Compatible devices: FlexMaster, VDW.SILVER RECIPROC, Raypex 5, Endo Easy Efficient, SILVER RECIPROC, Retreatments, BeeFill 2in1, Gutta Cut.

Recommended Documentation:

Getting Started Manual (Text):

(Ocr-Read Summary of Contents of some pages of the VDW CONNECT Locate Apex Locator Document (Main Content), UPD: 14 April 2023)
  • 2, Components Prior to rst use and after each use VDW.CONNECT Locate ® Apex Locator Clean, disinfect VDW.CONNECT Locate ® Measurement Cable Clean, disinfect VDW.CONNECT Drive ® Measurement Cable Clean, disinfect VDW.CONNECT Locate ® Clamp Clean, disinfect VDW.CONNECT Locate ® File Clip Clean, disinfect, sterilize VDW.CONNECT Locate ® Lip Clip Clean, disinfect, sterilize After each use, clean, disinfect and st…

  • 3, 2 VDW.CONNECT Locate ® Apex Locator operation ON/OFF/Standby button OFF ON This LED also displays the battery status (see chapter B below). File progress indication Bluetooth ® button Bluetooth ® OFF/not connected Bluetooth ® ON/searching device Device connected to VDW.CONNECT ® App Connection lost (see DFU chapter troubleshooting) Connection lost; default working length settings retrieved Battery status Green: charged Green flashing: device charging/standby mode Orange: low battery Red…

  • 4, R R R Uncombined Working modes 2 VDW.CONNECT Locate ® Apex Locator operation VDW.CONNECT Locate ® Apex Locator – Connected to VDW.CONNECT ® App. VDW.CONNECT Locate ® Apex Locator used with le clip in conjunction with the VDW.CONNECT ® App. VDW.CONNECT Locate ® Apex Locator – Unconnected. VDW.CONNECT Locate ® Apex Locator only used with le clip. The device is not used in conjunction with the VDW.CONNECT ® App. …

  • 5, VDW CONNECT Locate Apex Locator R R R Combined – with the VDW.CONNECT Drive ® Handpiece The handpiece barrier sleeve may look different in certain countries. The handpiece barrier sleeve may look different in certain countries. Bluetooth ® auto connection feature only available when both VDW.CONNECT Drive ® Handpiece and VDW.CONNECT Locate ® Apex Locator are combined via cable. Connects the second device automatically once Bluetooth ® connection is est…

  • 6, Always perform a closed-loop test before performing a treatment (see chapter 3). LED: Flashing green Sound: Fast pulsating tone Region coronal to the reference point for working length determination: The endodontic le can be moved further towards the reference point. LED: Solid green Sound: Solid tone Reference point for working length determination: This is the relevant position for determining the working length. LED: Solid blue Sound: Slow pulsating tone Coronal and medial region: Move …

  • 7, LED: Solid green Sound: Solid tone LED: Flashing red Sound: Fast pulsating tone The last green bar indicates the apical foramen. In combined mode, Apical Reverse (AR) is OFF by default on VDW.CONNECT Drive ® Handpiece. If AR is ON, VDW.CONNECT Drive ® Handpiece will go in reverse where the reference point has been set (LED shows solid green and solid tone is emitted). SHAPING TARGET and Apical Reverse (AR) settings as well as sound volume and scheme can be changed in the VDW.CONNECT ® App. Region beyond r…

  • 8, This feature checks the cables. This test should be performed before each treatment. If the closed-loop test failed, please refer to VDW.CONNECT Locate ® Directions for Use – 10 Troubleshooting. Make a closed-loop circuit with the VDW.CONNECT Locate ® or VDW.CONNECT Drive ® Measurement Cable: Hook the VDW.CONNECT Locate ® File Clip (4) to the lip clip (3) or put the lip clip (3) in contact with the endodontic le inserted in the VDW.CONNECT Drive ® Contra-angle. VDW.CONNECT Locate ® Apex Locator (1) central LED will …

  • 9, This icon appears at the bottom of the screen on VDW.CONNECT ® App. SN 12345 Bluetooth ® LED on the device switches to solid blue. Open VDW.CONNECT ® App. Wait a few seconds until VDW.CONNECT ® App detects the devices. Check the device serial number on the back of the device and click on the corresponding number on the iPad ® screen. When the VDW.CONNECT Locate ® Apex Locator is connected to VDW.CONNECT ® App: • Press the ON/OFF/Standby button to turn ON the VDW.CONNECT Locate ® Apex …

  • 10, Click on it to display the corresponding parameter dialogue. Bluetooth ® connection strength (displayed on critical levels) VDW.CONNECT Locate ® Apex Locator and VDW.CONNECT Drive ® Handpiece in combined mode Battery level (displayed on critical levels) Start your treatment. Access to VDW.CONNECT ® App parameters (volume, language, etc.), statistics and information Consult the file library and create or edit file sequences. User manuals VDW.CONNECT Locate ® Apex Locator information & settings Con…

  • 11, File progression VDW.CONNECT Drive ® Handpiece information Create or select a patient record number. Enter treatment data (notes, working lengths, last file used, obturation method). Select your file sequence (or file system). Visualize the torque that was applied to the file and file progression. Stop recording the treatment and send a PDF report by e-mail. Treatment screen in uncombined mode (VDW.CONNECT Locate ® Apex Locator only) Treatment screen in combined mode with VDW.CONNECT Drive ® Handpiece 5 Using VDW.CONNECT ® …

  • 12, Position of the file Indicates over-instrumentation An intermittent sound will be triggered. The LED on the hardware will be flashing red. This is the reference point for determining the working length. Reaching this level will trigger a solid sound. The LED on the hardware will be solid green. Default VDW.CONNECT Locate ® Apex Locator visualization Always perform a closed-loop test before performing a treatment (see chapter 3). I…

  • 13, Location of the file This is the default reference point for determining the working length. Customize VDW.CONNECT Locate ® Apex Locator visualization Always perform a closed-loop test before performing a treatment (see chapter 3). When combining the VDW.CONNECT Drive ® Handpiece with the VDW.CONNECT Locate ® Apex Locator, the Apical Reverse (AR) feature is initially OFF. To use AR, check chapter 6, VDW.CONNECT Locate…

  • 14, VDW CONNECT Locate Apex Locator VDW.CONNECT Locate ® Apex Locator technical data Volume and sound settings of the VDW.CONNECT Locate ® Apex Locator SHAPING TARGET parameters Test basic function of the device. VDW.CONNECT Drive ® Handpiece settings For more information on the VDW.CONNECT Drive ® Handpiece settings, please see the VDW.CONNECT Drive ® Handpiece documentation. When using your VDW.CONNECT Locate ® Apex Locator in combined mode with the VDW.CONNECT Drive ® Handpiece, the Apical Reverse (AR) function is initally OFF. To turn it ON, pres…

  • 15, VDW CONNECT Locate Apex Locator Enable or disable customized file progression settings. Move your reference point up or down within the green zone. Enable or disable SHAPING TARGET feature. Customize the default working length reference to your own preference. The SHAPING TARGET setting is OFF by default, and only available when the VDW.CONNECT Locate ® Apex Locator is connected to the VDW.CONNECT ® App. 7 SHAPING TARGET settings …

  • 16, Use a rubber dam during the endodontic procedure. Do not let the file or the lip clip come into contact with metallic dental structures. Root fractures, perforations, deep caries & large lateral canals might give inaccurate results. Moisten an extremely dry canal with FileCare ® EDTA to help provide a stable reading. Teeth with large apices might give false readings. Dry the access cavity. Use a file size adapted to the root canal diameter. An apex …

  • 17, SHAPING TARGET and Apical Reverse (AR) features can be used independently; By enabling the SHAPING TARGET feature (which is a VDW.CONNECT Locate ® Apex Locator setting), the Apical Reverse feature is not enabled automatically. This can be done in the parameter dialogue of the VDW.CONNECT Drive ® Handpiece. VDW.CONNECT Drive ® Handpiece provided function when connected with VDW.CONNECT Locate ® Apex Locator. SHAPING TARGET The SHAPING TARGET function allows the user…

  • 18, VDW CONNECT Locate Apex Locator 10 Symbols Image Description VDW.CONNECT Drive ® Handpiece connected; Apical Reverse (AR) is o. Apical Reverse (AR) is ON on VDW.CONNECT Drive ® Handpiece. Apical Reverse (AR) is OFF on VDW.CONNECT Drive ® Handpiece. Data transferring to VDW.CONNECT Drive ® Handpiece Image Description VDW.CONNECT Drive ® Handpiece combined with VDW.CONNECT Locate ® Apex Locator and both connected to the VDW.CONNECT ® App VDW.CONNECT Locate ® Apex Locator combined with VDW.CONNECT Drive…

  • 19, VDW CONNECT Locate Apex Locator 11 After use Image Description VDW.CONNECT Drive ® Handpiece combined with VDW.CONNECT Locate ® Apex Locator and both connected to the VDW.CONNECT ® App VDW.CONNECT Locate ® Apex Locator combined with VDW.CONNECT Drive ® Handpiece both with SHAPING TARGET and Apical Reverse features enabled VDW.CONNECT Drive ® Handpiece combined with VDW.CONNECT Locate ® Apex Locator but only VDW.CONNECT Drive ® Handpiece connected to the VDW.CONNECT ® App VDW.CONNECT Locate…

  • 20, VDW CONNECT Locate Apex Locator Manufacturer: VDW GmbH Bayerwaldstr. 15 81737 Munich Germany Tel +49 (0) 89 62734-0 Fax +49 (0) 89 62734-304 [email protected] MENCLOCBRC000 Rev.0/06.07.2018 …

  • VDW CONNECT Locate Apex Locator User Manual
  • VDW CONNECT Locate Apex Locator User Guide
  • VDW CONNECT Locate Apex Locator PDF Manual
  • VDW CONNECT Locate Apex Locator Owner's Manuals

DOC-e40caae9:

Recommended:
P430i, PRE- AMPLIFIER, 78-1600, N7000E

  • kÉï=~ë=çÑW=léÉê~íáåÖ=fåëíêìÅíáçåë=Ñçê=íÜÉ=^Åèìáëáíáçå=råáíEåçí=î~äáÇ=Ñçê=rp^L`~å~Ç~FMSKOMNT`bob`=^`táíÜ=`bob`=lãåáÅ~ãbåÖäáëÜ=Operating Instructions for the Acquisitio n Unit - With CEREC Omnicam ...

    cerec ac 82

  • FAQ - frequently asked questionsMade in Germanyhotty LED219945 22042016 / AFAQ - DeutschFAQ - EnglishFAQ - FrançaisFAQ - ItalianoFAQ - EspañolFAQ - PortuguêsFAQ - TürkçeFAQ - Polski󱯪󳍄󳎢󳓩󵡛󹭾󷎏󸯖FAQ - 󹽱󹿑 ...

    hotty 16

  • This manual must be read thoroughly and understood prior to usingthe Phasor™ Composite Heating System.USER’S MANUALFor use by qualied professionals only408800408800-I-V-77-ENG (2)Inter-Med, Inc.2200 South St.Racine, WI 53404-2500 - U.S.A.Tel.: +1-262-636-9755Fax: +1-262-636-9760Toll Free: +1-877-418-4782www.vista-dental.comEmergo EuropePrinsessegracht 202514 ...

    phasor 408800 24

  • NOTICE D'INSTRUCTIONINSTRUCTIONS FOR USEGEBRAUCHSANWEISUNGNOTA INFORMATIVA DE INSTRUCCIÓNFOGLIO D'ISTRUZIONICONTRE ANGLE OMNIPRATIQUECONTRA ANGLE FOR GENERAL DENTISTRYWINKELSTÜCKCONTRA ÁNGULO PARA ODONTOLOGÍA GENERALMANIPOLI D'ODONTOIATRIA GENERALE ...

    MONT BLANC 10000XL 68

  • DIAGNOdent® pen 2190Brief operating instructionSelect probestorage location:ecaps egarots esoohCeciwt sserP–+>>Press once>>Approx-probeOcclusal-probeWatch the display untilreference value shows andan audible signal is heard.... until audible signalsounds. Calibrationfinished.–+menuPress(within 3 Secs.)Press>>>>C 70>>–+menuC 7070>>90°Hold probe ontorefe ...

    DIAGNOdent pen 2190 2

  • U.S OnlyDigital Apex LocatorDual Function Apex LocatorQuick GuideVerify conductivity between the handpiece and the D.A.L. by connecting the 0.5 validation cable to the D.A.L. Make contact between the endo le and the lip hook cable. The 0.5 LED on the D.A.L. should light, verifying conductiov of the electric current between the D.A.L. and the endo le, allowing accurate measurement of the ...

    Digital Apex Locator 2

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 DMG
Icon-Etch
12 17/05
2 Vaniman
SANDSTORM MOBILE
10 18/10
3 NSK
FPB Series
2 09/08
4 Bien Air
OPTIMA INT
48 17/06
5 Miele professional
G 7881
13 27/10
6 POLYDENTIA
HY-DROP
2 08/06
7 KaVo
ELECTROmatic M
80 01/06
8 DMG
Icon
136 15/06
9 Dexcowin
iRay D3
2 29/10
Popular Right Now:
# Brand Model Document (PDF) Pages Size Check Date
1 TomTom
Blue&Me-
110 3.13 Mb 19.05.2023
2 LevelOne
FCS-1151
115 22.09.2023
3 KitchenAid
KGCC706RSS - 30" Sealed Burner Gas Cooktop
20 04.09.2023
4 ALC
AWS3377
104 13.06.2023
5 Motorola
VIP 1903
9 14.10.2023
6 American Standard
Ovalyn Undercounter Sink 0612
3 19.06.2023
7 Genie
GS-1530
67 21.11.2023
8 Nikon
SB-400
9 07.08.2023
9 SEVERIN
KAFFEEAUTOMAT MIT TIMER KA 4031
5 0.14 Mb 05.11.2023
Operating Impressions, Questions and Answers: