Specifications:1312/1312130-9847v.pdf file (24 Sep 2023)
|
Nonin 9847V Medical Equipment PDF Operator's Manual (Updated: Sunday 24th of September 2023 01:10:39 AM)
Rating: 4.2 (rated by 25 users)
Compatible devices: LifeSense LS1-9R, 8500, GO2 Achieve, 2120, 3150, WristOx2 3150, 9570, RespSense.
Recommended Documentation:
26, Nonin 9847V 19 Using the 9847V Pulse Oximeter Entering Setup Mode 1. With the unit in Standby mode, press and hold Alarm Limit Review while pressing and then releasing On/Standby. 2. Release Alarm Limit Review when 888 888 displays on the SpO 2 and pulse rate displays. Three brief beeps sounds, and ALr and dFt appear in the SpO 2 and pulse rate displays. NOTE: Entering setup mode with audible alarms disabled: 1. Press and hold Alarm Limit Review and Audible Alarm Disable while pressing and releasing On/St…
35, 28 Using the 9847V Pulse Oximeter Critically Low Battery Alarm The audible critically low battery alarm is a medium priority equipment alarm indicating the batteries have reached a critically low level and must be replaced immediately. The 9847V will not monitor animals after the batteries reach a critical power level. Also during this medium priority alarm, the visible Low Battery indicator blinks. If a high priority animal alarm condition exists before reaching critically low battery level, the audible and visible alarms “latch.” A “latched�…
33, 26 Using the 9847V Pulse Oximeter The 3rd and 6th bars of the CO 2 bar graph are lit if a medium priority (equipment) alarm is started. (See page 29 for additional alarm information.) CO 2 values are displayed as a range between two threshold values. The threshold values are located between each CO 2 bar. The values (displayed in both mmHg and kPa) are an approximate measurement of the change in CO 2 level in th…
58, 51 Technical Information This device is not made with natural rubber latex. Temperature (Operating) 0 °C to +40 °C (32 °F to +104 °F) Temperature (Storage/Transportation): -40 °C to +70 °C (-40 °F to +158 °F) Humidity (Operating) 10% to 95% noncondensing Humidity (Storage/Transportation): 10% to 95% noncondensing Altitude (Operating) Up to 3,000 meters (10,000 feet) Altitude (Hyperbaric Pressure): Up to 4 atmospheres Power Requirements Six 1.5…
27, Nonin 9847V 20 Using the 9847V Pulse Oximeter Disabling the Audible Alarms The audible alarms can be temporarily disabled, or they can be permanently disabled at power on when entering setup mode using the Audible Alarm Disable button. When the audible alarms are disabled, informational beeps continue to sound at the set volume, and the visible alarm indicators remain enabled. Temporarily Disabling the Audible Alarms (Maximum 2 Minutes) 1. With the unit on, press and then rele…
48, Nonin 9847V 41 Service, Support and Warranty Service, Support and Warranty The advanced digital circuitry within the Model 9847V requires no periodic maintenance or calibration. Nonin does not recommend field repair of the Model 9847V. For additional technical information, contact Nonin’s Technical Service department at: nonin.com All non-warranty work shall be done according to Nonin standard rates and charges in effect at the time of delivery to Nonin. All repairs include a complete retest of the Model 9847…
6, Nonin 9847V iv Figures Figure 1. Model 9847V Veterinary Pulse Oximeter and Carbon Dioxide Detector with Alarms ....................................................................................................... 7 Figure 2. Model 9847V Controls and Indicators.......................................................... 7 Figure 3. Replacing Batteries - Model 9847V ........................................................... 11 Figure 4. …
43, 36 Care and Maintenance Care and Maintenance 1. Wipe the device with a soft cloth dampened with a mild detergent or 10% bleach solution. Do not use undiluted bleach or any cleaning solution other than those recommended here, as permanent damage could result. 2. Dry with a soft cloth, or allow to air dry. Clean the device separately from the sensors. For instructions on cleaning pulse oximeter sensors, refer to the respect…
13, 6 Guide to Symbols Front Panel Buttons On/Standby Advance/Breath Beep Volume Control Alarm Limit Review Audible Alarm Disabled Display Indicators %SpO 2 SpO 2 Display Low Battery Indicator Pulse Rate Display Pulse Quality Indicator CO 2 Change in CO 2 Concentration No Breath Absence of CO 2 Detection Table 1: Symbols (Continued) Symbol Description …
28, 21 Using the 9847V Pulse Oximeter Disabling the Audible Alarms During Power On 1. With the unit in Standby, press and hold Audible Alarm Disable while pressing and then releasing On/Standby. 2. Release Audible Alarm Disable when 888 888 displays on the SpO 2 and pulse rate displays. 3. After the power on self-test, the Audible Alarm Disabled indicator is steadily lit. The animal alarms are set at the default limits. 4. The audible alarms can be re-enabled by pressing Audible Alarm Disable again. Setting Parameters NOTE: The Advance button sets yo…
5, Nonin 9847V iii Contents (Continued) Accessories ............................................................................................................. 42 Troubleshooting...................................................................................................... 43 Technical Information............................................................................................. 45 Manufacturer’s Declaration.............................................…
2, Nonin ® reserves the right to make changes and improvements to this manual and the products it describes at any time, without notice or obligation. Nonin Medical, Inc. 13700 1st Avenue North Plymouth, Minnesota 55441.USA +1 (763) 553-9968 (800) 356-8874 (USA and Canada) Fax: +1 (763) 553-7807 [email protected] Nonin Medical B.V. Prins Hendriklaan 26 1075 BD Amsterdam, Netherlands +31 (0)13 - 79 99 040 (Europe) Fax: +31 (0)13 - 79 99…
54, Nonin 9847V 47 Technical Information Table 9: Guidance and Manufacturer’s Declaration – Electromagnetic Immunity Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment— Guidance This device is intended for use in the electromagnetic environment specified below. The user of this device should ensure that it is used in such an environment. Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equatio…
42, 35 Carbon Dioxide Sensor and Airway Adapter Tube 2. Join the tabs on one side of the airway adapter tube onto either side of the CO 2 sensor (figure 9-A), then rotate the airway adapter tube (figure 9-B) and push firmly to set the other pair of tabs. You should hear a clicking sound as the pieces are connected together (figure 9-C). Figure 9: Connecting the Airway Adapter Tube to the CO 2 Sensor 3. Ensure the airway adapter tube and the CO 2 sensor are firmly attached to each other. Gently tug on the assembly…
56, 49 Technical Information Example - SpO 2 Exponential Averaging SpO 2 decreases 0.75% per second (7.5% over 10 seconds) Pulse Rate = 75 BPM Specific to this example: • The response of the 4-beat average is 1.5 seconds. Testing Summary SpO 2 accuracy, and low perfusion testing was conducted by Nonin Medical, Inc., as described below: SpO 2 Accuracy Testing SpO 2 accuracy testing is conducted during induced hypoxia studies on healthy, non-smoki…
50, 43 Troubleshooting Troubleshooting Problem Possible Cause Possible Solution The device won’t turn on. Batteries are depleted. Replace all six batteries. Batteries are installed incorrectly. Verify battery orientation, as illustrated inside battery compartment or on device label. The Low Battery indicator is steadily lit or flashing. Battery level is low or critically low. Replace all six batteries. Incorrect battery installation. Verify correct battery orientation. A dash appears in the leftmost position…
39, 32 Using the 9847V Pulse Oximeter Audible alarms re-enabled via Audible Alarm Disable button or ending of 2-minute disable When the audible alarms are re-enabled, and at least one alarm condition exists, the sound cycle for the highest priority alarm condition in effect at that time will be started. Note: The critically low battery state overrides the audible alarm disable. If a critically low battery condition occurs and the audible alarms are either temporarily or perm…
47, 40 Communications Connecting the Device into a Medical System Incorporating the device into a medical system requires the integrator to identify, analyze, and evaluate the risks to patient, operators, and third parties. Subsequent changes to the medical system after device integration could introduce new risks and will require additional analysis. Changes to the medical system that must be evaluated include: • Changing the system configuration • Adding devices to or disconnecting devices from the …
21, Nonin 9847V 14 Displays and Indicators Displays and Indicators The following is an overview of the device’s displays and indicators (figure 2). See “Visible Indicators” on page 23 for more detailed information. SpO 2 Display Identified by the %SpO 2 symbol, this 3-digit light-emitting diode (LED) display shows the current oxygen saturation percentage. This display also indicates if a pulse oximeter sensor fault or inadequate signal condition exists. If one exi…
57, 50 Technical Information Principles of Operation Pulse oximetry is a non-invasive method that passes red and infrared light through perfused tissue and detects the fluctuating signals caused by arterial pulses. Well-oxygenated blood is bright red, while poorly oxygenated blood is dark red. The pulse oximeter determines functional oxygen saturation of arterial hemoglobin (SpO 2 ) from this color difference by measuring the ratio of absorbed red and infrared …
34, 27 Using the 9847V Pulse Oximeter Audible Alarm Disabled Indicator If the device is turned on with the audible alarms permanently disabled, the yellow Audible Alarm Disabled indicator is steadily lit. If the audible alarms are temporarily disabled, the Audible Alarm Disabled indicator blinks. After the 9847V is turned on (and after exiting the setup mode, if applicable) and until a pulse oximeter or CO 2 sensor is plugged in for the first time, the Audible Alarm Disabled indicator blinks (or rema…
17, 10 Introduction Batteries 9847V is powered by six AA size alkaline batteries. Approximate battery capacity: • Pulse oximeter (SpO 2 ) only: 90 hours •CO 2 and pulse oximeter: 20 hours •CO 2 only: 24 hours The Low Battery indicator is lit when the battery capacity is low. Replace the batteries as soon as possible. Critical battery capacity is indicated by: • Low Battery indicator blinks • Medium priority (equipment) alarm To avoid loss of monitoring, batteries …
38, 31 Using the 9847V Pulse Oximeter Description of Alarm Sounds The pitch of the alarm sounds is the same as a “volume” beep (the tone heard when changing the breath beep sound volume). NOTE: Audible alarm volumes are fixed. The audible alarms can be disabled, but the volumes are not user-adjustable. The sound sequence for the high priority alarm consists of 3 short beeps, a delay, and then 2 more beeps within a 1-second period; then an identical pattern after a 1-second delay. This sound sequence then repeats every 10 seconds until the hig…
1, Nonin 9847V Operator’s Manual Model 9847V Veterinary Handheld Pulse Oximeter and Carbon Dioxide (CO 2 ) Detector English …
10, 3 Indications for Use This device must be able to measure the pulse properly to obtain an accurate SpO 2 measurement. Verify that nothing is hindering the pulse measurement before relying on the SpO 2 measurement. If the pulse quality or pulse rate displays are erratic or inaccurate, first examine the animal for any signs of distress and then reexamine sensor placement. Do not autoclave or immerse the device or sensors in liquid. Do not expose the device or components to excessive moisture or liquids. Do not …
40, 33 Carbon Dioxide Sensor and Airway Adapter Tube Carbon Dioxide Sensor and Airway Adapter Tube Carbon Dioxide Sensor The Model 9840SA CO 2 Sensor is a crescent-shaped device containing light emitting and detecting elements (figure 7) on the end of a cable that connects to the 9847V. The CO 2 sensor is connected onto the Model 9840AAT Airway Adapter Tube, which in turn is connected between the endotracheal tube and the breathing circuit …
Ariens Snow Blower Manual (#FZM288)
Sno-Thro 924 Series, 28, ariens/sno-thro-924-series.pdf
Lindy Guidance Switch 39632 (#6SY93V)
39632, 36, lindy/39632.pdf
#X1CKTA: ME 80 - ANNEXE 205 Guide
ME 80 - ANNEXE 205, 2, sennheiser/me-80-annexe-205.pdf
Craftsman User Manual Chainsaw 358.350203 (#E8M2ZP)
358.350203, 45, craftsman/358-350203.pdf
Laptop Guide #74O236
100WT10P, 2, philips/100wt10p.pdf
Automobile Parts Guidance #JOD69D
08W60-S5P-1A00-81, 2, honda-automobiles/08w60-s5p-1a00-81.pdf
1E95 ChallengerGebrauchsanweisung ..................................................................................................... 4Instructions for use ......................................................................................................... 10Instructions d'utilisation ................................................................................. ...
Challenger 1E95 160
INVACAREOXYGEN CONCENTRATORSINVACARE 5 & 6Model 5LXO2 with SensO2Model 5LXO2T with SensO2Model 6LXO2 with SensO2Model 6LXO2T with SensO2Model 6LXO2H with SensO2Model 6LXO2HT with SensO2INVACARE 3 & 5Model 3LXModel 5LXSERVICE MANUALDEALER: KEEP THIS MANUAL. THE PROCEDURES IN THIS MANUAL MUSTBE PERFORMED BY AN AUTHORIZED DEALER ONLY. ...
6LXO2 72
US-17 Rheumatism Hand Phantom Caution: Don’t mark on the phantom with a pen or leave printed materials contacted on its surface. Ink marks on the phantom will be irremovable. Contents Components and handling precautions ......... P.1Examination and cleaning ............................... P.2Ultrasound image .................... ....................... Back Cover ...
US-17 4
Instruction ManualInstruzioni per l’usoGebrauchsanweisungMode d’emploiGebruiksaanwijzingManual de instruccionesРуководство по эксплуатацииﺕﺎﻤﻴﻠﻌﺘﻟﺍ ﻞﻴﻟﺩНаръчник с инструкцииNávod k použitíBrugsanvisningΕγχειρίδιο ΟδηγιώνKasutusjuhendKäyttöohjeUpute za korištenjeHasználati útmutatóNaudojimo instruk ...
HJA-306 156
Add this addendum to the front of your HAMILTON-C2 Operator’s Manual. The HAMILTON-C2 software version 2.2.x introduces some important enhance-ments and updates to the device software to further improve the performance of the device and changes to the Operator’s Manual. This addendum summarizes the changes.Changes to Operator’s Manual This addendum provides updates for th ...
Hamilton-C2 118
SOLO2™ Quick Reference Guide 1 Part No 1163220NAVIGATING THE SOLO2™ LCD SCREENQUICK REFERENCE GUIDENOTE:Thisguideismeanttobeusedonlyasabrief,generalreference.Forcompleteoperatinginstructions,alwaysrefertotheOperator’sManual.Turning Concentrator On/OffNOTE:Forthisprocedure,refer� ...
SOLO 2 4
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Cobi Rehab | XXL-Rehab |
8 | 10/11 | ||
2 | AtriCure | nContact CS-3000 |
12 | 19/11 | ||
3 | Hanna | HI 2400 |
32 | 27/06 | ||
4 | Medionic | Ionic-Pulser PRO3 |
6 | 07/07 | ||
5 | Invacare | Softform |
16 | 29/06 | ||
6 | elepho | eClip |
17 | 14/06 | ||
7 | Hill-Rom | Liko Multirall 200 |
16 | 11/07 | ||
8 | CooperSurgical | Mityvac 10022 |
20 | 01/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Cembre | PO7000 |
18 | 30.11.2023 | ||
2 | My Weigh | durascale 50 |
6 | 04.09.2023 | ||
3 | BT | 4000 Classic |
64 | 2.17 Mb | 16.06.2023 | |
4 | Sanyo | DP42848 |
57 | 5.9 Mb | 04.10.2023 | |
5 | Samsung | HT-ES6600 |
248 | 8.87 Mb | 26.05.2023 | |
6 | Renkforce | RF1000 |
112 | 02.08.2023 | ||
7 | Seiko I Infotech | LP-1020 |
290 | 07.08.2023 | ||
8 | Telstra | 8950 |
31 | 09.06.2023 | ||
9 | Sapido | RB-1232 |
110 | 7.44 Mb | 23.11.2023 | |
10 | Philips | DS8550 |
23 | 27.05.2023 |