TriangleTube MAXI-FLO MF-135 Installation And Maintenance Manual

Installation And Maintenance Manual for TriangleTube MAXI-FLO MF-135 Industrial Equipment (12 pages)

Specifications:

1666/1666963-maxiflo_mf135.pdf file (21 Jan 2024)
  • Manufacturer: TriangleTube
  • Category of Device: Industrial Equipment
  • Document: MAXI-FLO MF-135, File Type: PDF Installation And Maintenance Manual
  • Updated: 21-01-2024
  • Count of Pages: 12
Download MAXI-FLO MF-135 Manual (12 pages)

Read TriangleTube MAXI-FLO MF-135 Document Online:

Data: UPD 21st January 2024

TriangleTube MAXI-FLO MF-135 Industrial Equipment PDF Installation And Maintenance Manual (Updated: Sunday 21st of January 2024 12:12:05 PM)

Rating: 4.9 (rated by 54 users)

Compatible devices: TTP Series, MAXI-FLO MF 350 PT Series, Stripe CDG045Dhs, BT3N, RolloTron Comfort 1623 45 19, Fill-Master 5000, VTR184P11, NRR3060-QC.

Recommended Documentation:

Text Version of TriangleTube MAXI-FLO MF-135 Installation And Maintenance Manual (Summary of Contents)

(Ocr-Read of the TriangleTube MAXI-FLO MF-135 Document (Main Content), UPD: 21 January 2024)
  • 1, Warranty Registration Card must be filled out by the customer and mailed within thir- ty (30) days of installation in order to gain warranty coverage. When receiving a Triangle Tube product, any claims for damage or shortage in ship- ment must be filed immediately against the transportation company by the…

  • 2, TriangleTube MAXI-FLO MF-135 Table of Contents i PRODUCT & SAFETY INFORMATION INSTALLATION Code Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Locating the Maxi-Flo Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Automatic Chlorin…

  • 3, TriangleTube MAXI-FLO MF-135 Product & Safety Information 1 Prolonged Immersion May Cause Hypothermia Hypothermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6ºF. The symptoms of hypothermia include dizziness, fainting, drowsi- ness, lethargy, and an …

  • 4, TriangleTube MAXI-FLO MF-135 Installation 2 CODE COMPLIANCE Maxi-Flo Heat Exchanger installation must conform with the instructions in this manual and where applicable: • Local, state, provincial, and national codes, laws, regulations and ordinances. LOCATING THE MAXI-FLO HEAT EXCHANGER • The Maxi-Flo ® is not intended for o…

  • 5, Installation 3 GENERAL PIPING • Typical pool or spa piping is plumbed as follows (see Figures 1 & 2): - Inlet of the filter is piped directly to the dis- charge side of the filter pump. - Outlet of the filter is piped to the inlet side of the Maxi-Flo ® heat exchanger. - The return …

  • 6, Installation 4 • Not maintaining proper chemical levels and/or not changing the water on a regular basis can promote unsanitary water conditions. Not maintaining proper water chemistry levels as listed in the Operating Restrictions section can cause damage to the heat exchanger and void any wa…

  • 7, Installation 5 5 1 5 5 13 12 4 9 14 5 10 5 13 6 To the pool Heating zones return Heating zones supply 16 16 7 7 2 3 PVC PV C Stainless Steel or CPVC 17 By Pass Piping From the pool Stainless Steel or CPVC Chlorinator 1. Maxi-Flo Heat Exchanger 2. Boiler 3. Boiler Water Circuit 4. Sensor or Aquastat 5. Isolation Val…

  • 8, Installation 6 1. Maxi-Flo Heat Exchanger 2. Boiler 3. Boiler Water Circuit 4. Sensor or Aquastat 5. Isolation Valve 6. Check Valve 7. Circulators 9. Filtration 10. Pump 12. Flow Switch 13. Thermometer 14. Drain Valve 16. Flow Control Valve 17. Check Valve / Anti-siphon Device Fig. 2 Recommended Pipin…

  • 9, TriangleTube MAXI-FLO MF-135 Installation 7 CPVC Male Nipple Rubber Coupling MF 135T or MF-260T Heat Exchanger FIG. 4 POOL PIPING CONNECTION MF-135T AND MF-260T ONLY Flow Switch Typ. McDonnell Miller FS4-3 FIG. 3-FIELD WIRING Note: Recommend pipe thread sealant - Loctite 30561 or equivalent …

  • 10, Installation 8 Thermal Output Maxi-Flo Stainless Steel Heat Exchangers Dimensions Model No. G PM Pressure Drop Ft Thermal Output Btu/hr Hot Water Flow GPM Pressure Drop F t Cold Water Flow Heat Transfer Surface Sq. Ft. 1 35,000 200,000 260,000 400,000 3 2 2 2 3 12 5 6 7 13 8 9 MF-135 MF-200 MF-260 MF-400 5 5 65 77 9…

  • 11, TriangleTube MAXI-FLO MF-135 Installation 9 Thermal Output Maxi-Flo Titanium Heat Exchangers Model No. GPM Pressure Drop Ft Thermal Output Btu/hr Hot Water Flow GPM Pressure Drop Ft Cold Water Flow Heat Transfer Surface Sq. Ft. 135,000 260,000 9 24 2 3 11 13 MF-135T MF-260T 92 92 5 6 Model No. ABC D EF Weight lb 20"…

  • 12, Additional quality water heating equipment available from Triangle Tube PRESTIGE CONDENSING WALL MOUNTED BOILER SMART SERIES INDIRECT FIRED WATER HEATERS TTP BRAZED PLATE HEAT EXCHANGERS - Exclusive tank-in-tank design - Stainless steel construction - Available in 7 sizes - Limited LIFETIME residential warranty …

DOC-ab853499:

Recommended:
PW-10, 2000, NetServer AA 4000, GNC420W

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 GUDEL
NRH Series
146 02/11
2 ABB
HT563146
130 14/02
3 THORLABS
MAX300 Series
26 10/08
4 ermengineering
APTM-600
30 02/11
5 Siemens
SINUMERIK 840D
520 29/01
6 Siemens
SINAMICS S120
58 25/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Nikon
F5 - F 5 SLR Camera
170 27.09.2023
2 LG
LN835R
50 10.01.2024
3 Toshiba
50PH18P
32 04.11.2023
4 NEC
LCD175VX - MultiSync - 17" LCD Monitor
48 13.01.2024
5 Moen
22372
1 16.12.2023
6 Orion
52080
22 14.02.2024
7 Honeywell
HHT-080 - Consumer Products - Room Air Purifier
20 1.77 Mb 22.08.2023
Operating Impressions, Questions and Answers: