Tektronix OI tek P5200A Series Manual, Installation And Safety Instructions

Manual, Installation And Safety Instructions for Tektronix OI tek P5200A Series Measuring Instruments (27 pages)

Specifications:

1658/1658990-oi_tek_p5200a_series.pdf file (09 Feb 2024)
  • Manufacturer: Tektronix
  • Category of Device: Measuring Instruments
  • Document: OI tek P5200A Series, File Type: PDF Installation And Safety Instructions
  • Updated: 09-02-2024
  • Count of Pages: 27
Download OI tek P5200A Series Manual (27 pages)

Read Tektronix OI tek P5200A Series Document Online:

Data: UPD 9th February 2024

Tektronix OI tek P5200A Series Measuring Instruments PDF Installation And Safety Instructions (Updated: Friday 9th of February 2024 01:11:54 AM)

Rating: 4.6 (rated by 81 users)

Compatible devices: WFM4000, TLA500 Series, MTM400, Type 130, TAP1500, TDS6604, P6248, 1720.

Recommended Documentation:

Text Version of Tektronix OI tek P5200A Series Manual, Installation And Safety Instructions (Summary of Contents)

(Ocr-Read of the Tektronix OI tek P5200A Series Document (Main Content), UPD: 09 February 2024)
  • 1, Tektronix OI tek P5200A Series P5200A Series High Voltage Differential Probes Installation and Safety Instructions & Product Documentation CD *P071288902* 071-2889-02 …

  • 2, Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Informatio…

  • 3, Tektronix OI tek P5200A Series 1 General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. While using this product, you may …

  • 4, General Safety Summary 2 Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source. Connect and Disconnect Properly. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Connect the probe …

  • 5, 3 General Safety Summary Use Proper AC Adapter. Use only the AC adapter specified for this product. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Terms in this Manual These terms may appear in this manual: WARNING. Warning statements iden…

  • 6, General Safety Summary 4 Symbols and Terms on the Product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the…

  • 7, Compliance Information 5 Compliance Information This section lists the safety and environmental standards with which the instrument complies. Safety Compliance EC Declaration of Conformity – Low Voltage Compliance was demonstrated to the following specification as listed in the Official Journal of the European C…

  • 8, Tektronix OI tek P5200A Series Compliance Information 6 Pollution Degree Description A measure of the contaminants that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external. Products should be used only in the environment for which they are rate…

  • 9, Tektronix OI tek P5200A Series Compliance Information 7 Installation & Measurement (Overvoltage) CategoryDescriptions Terminals on this product may have different installation or measurement (overvoltage) category designations. The installation and measurement categories are: Overvoltage Category IV.For measurements and installation…

  • 10, Tektronix OI tek P5200A Series Compliance Information 8 Environmental Considerations This section provides information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling an instrument or component: Equipment Recycling. Production of this equipment required th…

  • 11, Operating Considerations 9 Operating Considerations Specification P5200A P5202A Bandwidth 50 MHz 100 MHz Maximum measurable differential voltage (DC + Peak AC) 1 50X: ±130 V 500X: ±1300 V 20X: ±64 V 200X: ±640 V (V rms ) 50X: 92 V rms 500X: 920 V rms 20X: 45 V rms 200X: 450 V rms Maximum common m…

  • 12, Tektronix OI tek P5200A Series Operating Considerations 10 Figure 1: Specification table footnotes referring to the probe input limits on the P5200A and P5202A probes …

  • 13, Tektronix OI tek P5200A Series Operating Considerations 11 Specification P5205A P5210A Bandwidth 100 MHz 50 MHz Maximum measurable differential voltage (DC + Peak AC) 1 50X: ±130 V 500X: ±1300 V 100X: ±560 V 1000X: ±5600 V (V rms ) 50X: 92 V rms 500X: 920 V rms 20X: 396 V rms 200X: 2650 V rms 2 Maximum common mode voltage (DC + P…

  • 14, Operating Considerations 12 Figure 2: Specification table footnotes referring to the probe input limits on the P5205A and P5210A probes …

  • 15, Tektronix OI tek P5200A Series Operating Considerations 13 Characteristic Specification Temperature Operating 0 °C to +40 °C (+32 °F to +104 °F) Nonoperating -30 °C to +70 °C (-22 °F to +158 °F) Humidity Operating 5 to 85% R.H. 0 °C to +40 °C (+32 °F to +104 °F) Nonoperating 5 to 85% R.H. 0 °C to +40 °C (+32 °F to…

  • 16, Installation 14 Installation To connect the P5202A, P5205A, and P5210A probes to oscilloscopes that feature the VPI interface, you must use a Tektronix TPA-BNC Adapter. To disconnect the probes, first disconnect the probe from the circuit. Next, turn the collar counterclockwise to release the probe, a…

  • 17, 15 Installation Probe Power (P5200A Probe Only) The P5200A probe requires DC power that is provided by an external power supply. The supply is a standard accessory for the probe. WARNING. Use only the power supply that is included with the P5200A probe. Damage to the probe may result if a different power supply …

  • 18, Tektronix OI tek P5200A Series Installation 16 Connecting the Probe to the Circuit WARNING. To reduce risk of shock or fire, use only the accessories provided with the probe. Do not exceed either the voltage rating or category ratings (for example, CAT I, II, III, IV) of the probe or the probe accessory, whichever is the lesser of th…

  • 19, Standard Accessories 17 Standard Accessories P5200A, P5202A & P5205A Probe standard accessories Item Description Extender leads (196-3523-xx) The female banana connectors on each end of the leads fit into the probe input jacks. Use the extender leads to connect the probe to your circuit, either directly or throu…

  • 20, Standard Accessories 18 P5200A, P5202A & P5205A Probe standard accessories, (cont.) Item Description Hook clips (AC280-FL) Use these clips to make connections to component leads. Maximum ratings: 1000 V CAT III 600 V CAT IV Pincer clips (AC283-FL) These clips have a pair of finer contacts that close around leads …

  • 21, Standard Accessories 19 WARNING. To avoid risk of electric shock or fire, do not use the P5210A test probe or hook tip accessories on CAT III or CAT IV circuits. Refer to the derating table below. To avoid risk of electric shock or fire, when using the P5210A test probe or hooktip accessories with the P5200A, P52…

  • 22, Tektronix OI tek P5200A Series Standard Accessories 20 P5210A Probe standard accessories Item Description Extender leads (196-3523-xx) The female banana connectors on one end of the leads fit into the probe input leads. Use the extender leads to connect the probe to the test probes below. The test probes accept the hook tips in the …

  • 23, Standard Accessories 21 P5210A Probe standard accessories, (cont.) Item Description Small hook tips (TASH) (020-3070-xx kit) Use these tips to access test points in tight spaces. Screw the hook tips onto the TATP test probes and then clamp the hooks onto the circuit. WARNING. To reduce the risk of shoc…

  • 24, Tektronix OI tek P5200A Series Controls and Features 22 Controls and Features Controls and features Item Description Differential inputs The differential and common-mode input voltage ratings for the P5200A series probes differ between models. The highest ratings are for the P5210A probe and are rated for a maximum peak voltage of 5,600 V betwe…

  • 25, Controls and Features 23 Controls and features, (cont.) Item Description Attenuation selector button and indicators Press the button to select between the voltage range (attenuation) settings of the probe. The range and units are indicated on the probe and may be displayed on the oscilloscope screen, depend…

  • 26, Controls and Features 24 Controls and features Item Description Bandwidth limit button andindicators Press the button to limit the probe bandwidth to 5 MHz. The 5 MHz filter assists in the characterization and testing of power supplies in switch mode by removing all high frequency content, noise and harmonics …

  • 27, Controls and Features 25 CD Contents The documentation CD included with this booklet contains pdf files of the P5200A Series High Voltage Differential Probes Instruction Manual, and other documents to help you understand how to take differential measurements with your probe. …

DOC-98853892:

Recommended:
GOLD-PLUS, LN26A330, LX-HOO, 024 S

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Trotec
BS06
6 12/11
2 ABB
CB-2000
47 30/09
3 REED
C-322
20 16/11
4 Thermo Scientific
Orion 7070iX
40 01/10
5 Ocean Optics
NIR Series
54 30/10
6 CTEK
BATTERY ANALYZER
4 17/09

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 GE
3300
6 0.24 Mb 13.10.2023
2 FLIR
DNR100 SERIES
136 2.97 Mb 18.09.2023
3 Lenovo
V100
126 19.09.2023
4 Bissell
Easy Sweep 9974 Series
8 1.81 Mb 08.11.2023
5 TerraTec
GRABSTER AV 400MX
16 0.28 Mb 24.10.2023
6 KitchenAid
KUCS03CTWH0
6 05.11.2023
Operating Impressions, Questions and Answers: