Schiller FRED easyport Operation & User’s Manual

Operation & User’s Manual for Schiller FRED easyport Medical Equipment (51 pages)

Specifications:

1694/1694310-fred_easyport.pdf file (05 Nov 2023)
  • Manufacturer: Schiller
  • Category of Device: Medical Equipment
  • Document: FRED easyport, File Type: PDF Operation & User’s Manual
  • Updated: 05-11-2023
  • Count of Pages: 51
Download FRED easyport Manual (51 pages)

Read Schiller FRED easyport Document Online:

Data: UPD 5th November 2023

Schiller FRED easyport Medical Equipment PDF Operation & User’s Manual (Updated: Sunday 5th of November 2023 05:40:36 AM)

Rating: 4.8 (rated by 71 users)

Compatible devices: CARDIOVIT CS-104, CARDIOVIT AT-1, AT-101, FRED easy, AT-2plus, MAGLIFE LIGHT, PHYSIOGARD Touch 7, CARDIOVIT AT-2.

Recommended Documentation:

Text Version of Schiller FRED easyport Operation & User’s Manual (Summary of Contents)

(Ocr-Read of the Schiller FRED easyport Document (Main Content), UPD: 05 November 2023)
  • 1, FRED ® easyport ® User Guide Art. no.: 2.510544 Rev.: L *2.510544* Automated external defibrillator (AED) FRED ® easyport ® …

  • 2, Schiller FRED easyport Manufacturer SCHILLER AG Phone: +41 (0) 41 766 42 42 Altgasse 68 Fax: +41 (0) 41 761 08 80 CH-6341 Baar, Switzerland E-mail: [email protected] Web: www.schiller.ch Sales and Service Information The SCHILLER sales and service centre network is world-wide. For the address of your local distributer, contact …

  • 3, Page 3 User Guide Art. no.: 2.510544 Rev.: L Table of Content 1 Safety Notes .............................................. 5 1.1 User profiles.......................................................................... 5 1.2 Responsibility of the User .........................................…

  • 4, Page 4 Art. no.: 2.510544 Rev.: L 4.3.1 Applying the electrodes.................................................................... 26 4.3.2 Checking the electrodes .................................................................. 27 4.3.3 Device is not working, error message........................…

  • 5, Page 5 Safety Notes 1 User Guide User profiles 1.1 Art. no.: 2.510544 Rev.: L 1 Safety Notes 1.1 User profiles The following people may use the FRED easyport: • Physicians or other trained medical personnel • other people (non-professionals) trained in early defibrillation • other people not …

  • 6, 1 Safety Notes 1.4 Contra-indication Page 6 Art. no.: 2.510544 Rev.: L 1.4 Contra-indication 1.5 Organisational Measures 1.6 Safety-Conscious Operation The device must not be used if the patient: – is responsive – is breathing – has a pulse The device is not designed for sterile use. Do not use this d…

  • 7, Page 7 Safety Notes 1 User Guide Maintenance 1.7 Art. no.: 2.510544 Rev.: L 1.7 Maintenance 1.8 General Safety Notes 1.9 General Notes Regarding the Unit Danger of electric shock! Do not open the device. There are no serviceable parts inside. Refer servicing to qualified personnel only. Before cleanin…

  • 8, 1 Safety Notes 1.10 Terms of Warranty Page 8 Art. no.: 2.510544 Rev.: L 1.10 Terms of Warranty Your SCHILLER FRED easyport is warranted against defects in material and manu- facture, as stated in the Terms and Conditions. Excluded from this warranty is dam- age caused by an accident or as a result of improper handl…

  • 9, Page 9 Safety Notes 1 User Guide Symbols 1.11 Art. no.: 2.510544 Rev.: L 1.11 Symbols 1.11.1 Symbols used in this user guide The safety level is classified according to ISO 3864-2. The following overview con- tains the safety symbols and pictograms used in this user guide. For a possibly dangerous si…

  • 10, 1 Safety Notes 1.11 Symbols Page 10 Art. no.: 2.510544 Rev.: L 1.11.2 Symbols used in different locations Manufacturer symbol 0xxx Notified body of the CE certification • CE 0123TÜV-SÜD Produkte Service GmbH • CE 408 TÜV AUSTRIA Service Note accompanying documents! Consult user guide! Symbol for the re…

  • 11, Page 11 Safety Notes 1 User Guide Symbols 1.11 Art. no.: 2.510544 Rev.: L 1.11.3 Symbols used on the device 1.11.4 Symbols used on the battery BF symbol. The device's signal input is defibrillation-protected. IPX4 The device is protected against splashing water. Defibrillation …

  • 12, 1 Safety Notes 1.11 Symbols Page 12 Art. no.: 2.510544 Rev.: L 1.11.5 Symbols used on the electrode package • Remove the patient's clothes • Open the electrode packaging • Peel off the protective foil Disposable item; do not reuse Do not bend packing Storage temperature for the electrodes Latex-fr…

  • 13, Page 13 Components and Operation 2 User Guide General Information 2.1 Art. no.: 2.510544 Rev.: L 2 Components and Operation 2.1 General Information FRED easyport® is an automated external defibrillator (AED). The FRED easyport® is available as a semi-automatic or manual defibrillator. The regulations gover…

  • 14, 2 Components and Operation 2.2 Design Page 14 Art. no.: 2.510544 Rev.: L 2.2 Design The FRED easyport is a battery-powered automated external defibrillator (AED) that delivers biphasic defibrillation pulses. The patient is defibrillated via disposable adhesive electrodes (pads), which also acquire the ECG signal f…

  • 15, Page 15 Components and Operation 2 User Guide Operating Elements 2.3 Art. no.: 2.510544 Rev.: L 2.3 Operating Elements Fig. 2.1 Operating Elements (1) Green button to switch the device on/off (2) Rubber seal for SD minicard (3) Yellow indicator lamp; lit as long as no electrodes are connected (4) Electrode conne…

  • 16, Schiller FRED easyport 2 Components and Operation 2.4 Display Page 16 Art. no.: 2.510544 Rev.: L 2.4 Display The following information is displayed on the LCD: (1) Time passed and shocks delivered since the device has been switched on (2) Perform the function test at the next opportunity (see page 36 section 6.1.3) (3) Memory card insert…

  • 17, Schiller FRED easyport Page 17 Components and Operation 2 User Guide Function 2.5 Art. no.: 2.510544 Rev.: L 2.5 Function 2.5.1 Self-test Automatic self-test at switch-on To ensure its readiness for use, the device runs a self-test to check the unit and the battery. Manual self-test A manual self-test can be performed at any time. During…

  • 18, 2 Components and Operation 2.5 Function Page 18 Art. no.: 2.510544 Rev.: L 2.5.4 Device identifies a shockable rhythm If the analysis program detects a shockable rhythm, the defibrillation energy is charged and the user is prompted to deliver the shock. Shockable rhythms are: • Ventricular Fibrillatio…

  • 19, Schiller FRED easyport Page 19 Components and Operation 2 User Guide Function 2.5 Art. no.: 2.510544 Rev.: L 2.5.5 Device detects no shockable rhythm If the analysis program does not identify a shockable rhythm, the FRED easyport in- forms the user: • that no shock is required • that he or she should alternately carry out 30 che…

  • 20, 2 Components and Operation 2.6 Voice support Page 20 Art. no.: 2.510544 Rev.: L 2.6 Voice support Once the device is switched on, it runs a self-test and shows the software and hard- ware version. The following instructions will be spoken by the device: Voice Display Note a Place electrodes on chest and …

  • 21, Page 21 Components and Operation 2 User Guide Procedure in case of a cardiac arrest 2.7 Art. no.: 2.510544 Rev.: L 2.7 Procedure in case of a cardiac arrest This procedure applies to adults and children. Fig. 2.3 AED algorithm (ERC 2010) or cardiopulmonary resuscitation (CPR) with defibrillation •Collapse, cardia…

  • 22, Schiller FRED easyport 3 Operation 3.1 Initial operation Page 22 Art. no.: 2.510544 Rev.: L 3 Operation 3.1 Initial operation 3.1.1 Inserting the Battery The battery inserted into the device has a life time of approx. 2.5 years, if the device is switched on only for the regular maintenance intervals. Additional switch-ons, and storag…

  • 23, Page 23 Operation 3 User Guide Initial operation 3.1 Art. no.: 2.510544 Rev.: L 3.1.2 Ensuring operational readiness Function test The function test is performed by the user (see Function test page 36). Stipulated interval: • when the device is put into operation or delivered to the end user. • After that, ev…

  • 24, Schiller FRED easyport 4 Defibrillation 4.1 Application guidelines Page 24 Art. no.: 2.510544 Rev.: L 4 Defibrillation 4.1 Application guidelines Observe the following guidelines to ensure successful and safe defibrillation. Other- wise, the lives of the patient, the user and bystanders are in danger. 4.2 Additional Safety Notes I…

  • 25, Schiller FRED easyport Page 25 Defibrillation 4 User Guide Applying the defibrillation electrodes 4.3 Art. no.: 2.510544 Rev.: L 4.3 Applying the defibrillation electrodes Adult and paediatric electrodes Adult electrodes The adult electrodes with the blue connector are used for adults and children from 25 kg. Paediatric electrode…

  • 26, 4 Defibrillation 4.3 Applying the defibrillation electrodes Page 26 Art. no.: 2.510544 Rev.: L 4.3.1 Applying the electrodes Adults and children from 25 kg Electrode placement is the same for adults and for and children weighing 25 kg or more (see Fig. 4.1 Adult electrode application sites and Fig…

  • 27, Schiller FRED easyport Page 27 Defibrillation 4 User Guide Applying the defibrillation electrodes 4.3 Art. no.: 2.510544 Rev.: L 4.3.2 Checking the electrodes 4.3.3 Device is not working, error message If the resistance between the skin and an electrode is too high, a message is displayed and the yellow electrode LED (A) (fig. 4.2…

  • 28, Schiller FRED easyport 4 Defibrillation 4.4 Defibrillation procedure Page 28 Art. no.: 2.510544 Rev.: L 4.4 Defibrillation procedure When the device is switched on, it gives spoken and displayed instructions up to the defibrillation. Exactly follow the instructions. Step 1 Switching on and preparing the device Step 2 Analysis 1. Switch the…

  • 29, Schiller FRED easyport Page 29 Defibrillation 4 User Guide Defibrillation procedure 4.4 Art. no.: 2.510544 Rev.: L Step 3 Shock delivery As soon as the energy for a shock is charged, the device prompts the user to deliver the shock by pressing button 3. Danger of electric shock! • Do not, under any circumstances, touch the patient du…

  • 30, 4 Defibrillation 4.5 Defibrillation in manual mode Page 30 Art. no.: 2.510544 Rev.: L 4.5 Defibrillation in manual mode The FRED easyport version including the manual option is clearly labelled with a red foil. If the user does not activate the manual mode during switch on, the unit will run in the semi…

  • 31, Schiller FRED easyport Page 31 Defibrillation 4 User Guide Defibrillation in manual mode 4.5 Art. no.: 2.510544 Rev.: L Shock delivery in manual mode 5. Deliver the shock by pressing the button . If the shock is not released within 20 seconds, an internal safety discharge is initiated. Danger to the patient! Before you relea…

  • 32, 4 Defibrillation 4.5 Defibrillation in manual mode Page 32 Art. no.: 2.510544 Rev.: L 4.5.1 Finishing the therapy 1. Switch the device off as soon as the therapy is finished (keep the button pressed for approx. 3 seconds). 2. Disconnect the plug of the electrode line. 3. Carefully pull the electrodes off the patie…

  • 33, Schiller FRED easyport Page 33 Documentation of an Intervention 5 User Guide Inserting the memory card 5.1 Art. no.: 2.510544 Rev.: L 5 Documentation of an Inter- vention To document an intervention using the unit, the following data can be recorded using the memory card: • ½ hour of ECG data • 500 events with date and time of int…

  • 34, 6 Maintenance 6.1 Maintenance intervals Page 34 Art. no.: 2.510544 Rev.: L 6 Maintenance 6.1 Maintenance intervals 6.1.1 Visual inspection of the device Inspect the device and electrodes for the following: Device casing not broken or cracked Electrode connection undamaged? Schiller memory card inserted? Expiration da…

  • 35, Schiller FRED easyport Page 35 Maintenance 6 User Guide Maintenance intervals 6.1 Art. no.: 2.510544 Rev.: L 6.1.2 Performing a manual self-test • When the device is in mobile use and therefore exposed to changing ambient con- ditions, we recommend to regularly perform a self-test. • The battery discharge due to the self-test is reduce…

  • 36, 6 Maintenance 6.1 Maintenance intervals Page 36 Art. no.: 2.510544 Rev.: L 6.1.3 Function test Starting the function test Function test results Function test successful The message “Regeneration SUCCEEDED” is displayed. Function test not successful The message “Regeneration FAILED” is displayed. If t…

  • 37, Page 37 Maintenance 6 User Guide Maintenance intervals 6.1 Art. no.: 2.510544 Rev.: L 6.1.4 Maintenance interval for the battery 6.1.5 Battery disposal 6.1.6 Disposal at the end of its useful life Important • The battery is maintenance-free during its normal life. • The spare battery has a life…

  • 38, 6 Maintenance 6.2 Cleaning Page 38 Art. no.: 2.510544 Rev.: L 6.2 Cleaning 6.2.1 Cleaning the casing Wipe the unit's casing with a tissue dampened in a cleaning or disinfection solu- tion (70% alcohol). Make sure that no liquid enters the unit. 6.2.2 Accessories and disposables Your local representative stocks al…

  • 39, Schiller FRED easyport Page 39 Maintenance 6 User Guide Error detection 6.3 Art. no.: 2.510544 Rev.: L 6.3 Error detection If it is not possible to get the device back into operating condition within a reason- able period of time, continue cardiopulmonary resuscitation until the rescue ser- vice arrives. Forcing a shut-dow…

  • 40, 6 Maintenance 6.3 Error detection Page 40 Art. no.: 2.510544 Rev.: L “Error xxx-xxx” • Device is not ready for opera- tion or defective. Switch the unit off and then on again to confirm. If the error message is still displayed, continue cardi- opulmonary resuscitation until the rescue service arrives. Repl…

  • 41, Page 41 Maintenance 6 User Guide Error detection 6.3 Art. no.: 2.510544 Rev.: L 6.3.1 Preventing electromagnetic interferences The user can take the following measures to solve this problem: • Increase the distance to the source of interference • Turn the device to change the angle of radiation. • Only use orig…

  • 42, Schiller FRED easyport 7 Technical Specifications 7.1 System Specifications Page 42 Art. no.: 2.510544 Rev.: L 7 Technical Specifications 7.1 System Specifications Where nothing else is indicated, the data refers to a temperature of 25 °C. Manufacturer SCHILLER AG Device name FRED easyport (First Responder External Defibrillator) …

  • 43, Page 43 Technical Specifications 7 User Guide Safety standard 7.2 Art. no.: 2.510544 Rev.: L 7.2 Safety standard DEFIBRILLATOR IEC/EN 60601-2-4 – the device is designed for more than 2500 shocks EMC • IEC/EN 60601-2-4 • CISPR 11 class B The device can be exposed to the following interferences without …

  • 44, Schiller FRED easyport 7 Technical Specifications 7.3 Defibrillation impulse Page 44 Art. no.: 2.510544 Rev.: L 7.3 Defibrillation impulse Shape • Biphasic pulsed defibrillation impulse with fixed physiological optimum phase du- rations • Near stabilisation of the emitted energy in function with the patient resistance …

  • 45, Schiller FRED easyport Page 45 Technical Specifications 7 User Guide Defibrillation impulse 7.3 Art. no.: 2.510544 Rev.: L 7.3.1 Storage of an intervention (option) Safety discharge if: • the battery voltage is insufficient • the device is defective, • the device is turned off Shock delivery Via disposable adhesive electrode…

  • 46, Schiller FRED easyport 8 Appendix 8.1 Accessories Page 46 Art. no.: 2.510544 Rev.: L 8 Appendix 8.1 Accessories 8.2 Literature European Resuscitation Council (2010) Guidelines 2010 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care (13:523–542 DOI 10.1007/s10049-010-1368-x). American Heart Association (2010) Guidel…

  • 47, Page 47 Appendix 8 User Guide Glossary 8.3 Art. no.: 2.510544 Rev.: L 8.3 Glossary ACLS Advanced Cardiovascular Life Support. (ACLS Manual AHA 2010) ERC European Resuscitation Council AED Automated external defibrillator. This term is also used for semi-automatic defibrilla- tors (SAED). SAED Semi-automatic…

  • 48, Schiller FRED easyport 8 Appendix 8.4 Inspection Report Page 48 Art. no.: 2.510544 Rev.: L 8.4 Inspection Report The user manual must be read before the inspection. Recommended inspection interval: Every 4 months Serial no.: ________________ In case of a defect, please contact the service department of your ho…

  • 49, Schiller FRED easyport Page 49 Index 9 User Guide Art. no.: 2.510544 Rev.: L 9 Index A Accessories and disposables ............................................. 38 AED .................................................................................... 13 Applying the electrodes ......................................................…

DOC-de88ca3c:

Recommended:
HP4, CXB-SH-e-0913, GM-520T, Stylus T40W

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Barco
Coronis 5MP Mammo
38 0.49 Mb 22/10
2 Contec
CMS800G
31 04/01
3 Breas
Vivo 40
70 07/10
4 Honeywell
SiX Series
4 02/12
5 Hologic
Fluoroscan InSight FD Mini C-arm
11 01/02
6 Haag-Streit
BP 900
18 12/08
7 Seca
231
3 10/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Philips
8P4841C
2 0.09 Mb 16.02.2024
2 American Standard
Countertop Sink 0293.004
1 0.18 Mb 11.02.2024
3 Jayco
Melbourne 2011
106 26.09.2023
4 iGenix
IG3900
4 28.11.2023
5 Yamaha
YZF-R1(B) 2012
556 18.02.2024
6 Asus
L4E
57 2.16 Mb 19.11.2023
Operating Impressions, Questions and Answers: