Isotech 17702W User Maintenance Manual/handbook

User Maintenance Manual/handbook for Isotech 17702W Furnace (48 pages)

Specifications:

1914/1914931-17702w.pdf file (10 Dec 2023)
  • Manufacturer: Isotech
  • Category of Device: Furnace
  • Document: 17702W, File Type: PDF User Maintenance Manual/handbook
  • Updated: 10-12-2023
  • Count of Pages: 48
Download 17702W Manual (48 pages)

Read Document Online:

Data: UPD 10th December 2023

Isotech 17702W Furnace PDF User Maintenance Manual/handbook (Updated: Sunday 10th of December 2023 12:54:23 PM)

Rating: 4.2 (rated by 17 users)

Compatible devices: 465, ITL-M-17701, ITL- M-17702, 414, Neycraft 9491003A, F80A, 936, 2100541.

Recommended Documentation:

Text Version of Isotech 17702W Manual (Summary of Contents)

(Ocr-Read of the Isotech 17702W Document (Main Content), UPD: 10 December 2023)
  • 22, Page 22 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) To change the DATE and TIME or LANGUAGE: • To access these features, you will need to log in as the Engineer. • When logged in, scroll to the INSTRUMENT tab on the Engineer homepage • Press the SCROLL button to enter • Scroll …

  • 19, Isotech 17702W Page 19 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) Principle of operation The principle of the operation of heat pipes is as follows. The inside walls of the inner and outer tubes are covered with a fine wire mesh screen. When heated, the small amount of sodium with which the heat pipe is charged vapo…

  • 2, Page 2 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) GUARANTEE ⓒIsothermal Technology Limited This instrument has been manufactured to exacting standards and is guaranteed for twelve months against electrical break-down or mechanical failure caused through defective material or workmanship, provided t…

  • 47, Isotech 17702W Page 47 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) ISOTECH I-CAL EASY This application allows logging of data from the furnace. Additionally, if a license is purchased it allows for fully automatic calibration including certificate printing and the calculation of coefficients. Refer to…

  • 1, Page 1 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (12–01/18) HEATPIPE FURNACE FOR MODELS 17702W 17702P 17702S User Maintenance Manual/Handbook Isothermal Technology …

  • 23, Page 23 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) d) Last week e) Last day f) Last hour g) None 8. When the selection is entered by pressing the SCROLL button, the transfer will begin (this may take several minutes depending on the selection made) 9. When the transfer is complete, remove the USB stic…

  • 11, Page 11 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) Rear View 1. Cooling coil connection (not on W version) 2. Cooling coil connection (not on W version) 3. Mains Power cable …

  • 28, Isotech 17702W Page 28 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) CONNECTING THE FURNACE TO A LIQUID COOLANT SUPPLY (NOT REQUIRED FOR MODEL 17702W) This furnace has a cooling coil installed on the top panel, this is to allow a cooler top panel working surface that will prevent a hazard to the user when the furnace…

  • 39, Isotech 17702W Page 39 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) The furnace temperature is then reduced to a value slightly below the melt temperature. The temperature falls until the first solid nucleus of metal is formed, at which stage the temperature drop is arrested. With both liquid and solid metal present in the cell, a c…

  • 33, Isotech 17702W Page 33 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) ELIMINATING CONTAMINATION DURING THE CALIBRATION OF HIGH TEMPERATURE THERMOMETERS It is quite feasible to heat a high temperature thermometer to 1000°C and return it to ambient temperature without altering the water triple point resistance value by mor…

  • 40, Isotech 17702W Page 40 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) DEFINING FIXED POINTS AND RELATED DATA FIXED POINT ITS 90 TEMPERATURE PRESSURE COEFFICIENT ITL CELL DESIGNATION SUITABLE APPARATUS FOR CELL OPERATION °C K mK/ bar mK/m HEAD OF SUBSTANCE ARGON TP -189.3442 83.8058 (N…

  • 25, Isotech 17702W Page 25 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) Ch1 Holdback value The value to be used in triggering holdback. Ch2 Holdback As for Ch1 Holdback, above but for channel 2. Ch2 Holdback value As for ‘Ch1 Holdback value’, above, but for channel 2. Ramp Style Ramp style appli…

  • 24, Isotech 17702W Page 24 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) Below is the procedure to install a program for Channel 1 (Heatpipe furnace) To install for The Annealing furnace, ensure Channel 2 is enabled in the settings: 1. Log in as the Engineer 2. Scroll to PROGRAMMER and enter 3. Scroll to SET UP and enter 4. Scrol…

  • 31, Isotech 17702W Page 31 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) CALIBRATION APPARATUS FOR ALUMINIUM, SILVER AND COPPER FIXED POINTS INTRODUCTION Using high temperature thermometers presents many problems due to strain and contamination which can very easily be induced into the thermometer during temperature cy…

  • 44, Page 44 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) SEALED METAL FREEZING POINT CELL A High-purity graphite crucible and cover B High-purity graphite sleeve C High-purity metal D Fused-quartz envelope, filled to give a pressure of 1 standard at…

  • 38, Page 38 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) THERMOMETRIC FIXED POINTS; A TUTORIAL The International Temperature Scale, the scale most used in science and industry, is based on a series of fixed point temperatures. Fixed points involve two-phase or three-phase equilibria of, ideal…

  • 29, Page 29 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) CALIBRATION APPARATUS FOR ZINC, ALUMINIUM AND SILVER FIXED POINTS GENERAL ASSEMBLY OF FIXED POINT CELL INSIDE THE HEATPIPE A Insulation: Superwool 670HT 932-20-52 (to keep thermometer head cool) B Fixed Point Cell C Inconel Cell B…

  • 21, Isotech 17702W Page 21 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) 1. Record the value on the reference thermometer and scroll to DISPLAY VALUE tab and press enter 2. This will bring up a soft keyboard, use this keyboard to enter the exact temperature displayed by the calibrated reference standard 3. Press the PAGE button to…

  • 15, Isotech 17702W Page 15 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) QUICK START Locate the furnace in a suitable, level location. Leave a minimum of 150mm of space around and 500mm above the furnace for air circulation. Ensure there is a suitable water supply or circulation system for the cooling of the furnace (see page 28) and power …

  • 16, Isotech 17702W Page 16 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) USING THE CONTROLLER The controller installed on this equipment uses an advanced three loop controller with a multi-channel sensor input. Other features of the controller are: • Built in data logging • Ethernet connection • USB host fo…

  • 30, Page 30 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) METHOD OF OPERATION 1. By adjusting set-point to a few degrees above the appropriate melting point, the cell (zinc, aluminium or silver) is melted in an essentially temperature gradient free potassium-filled heat-pipe. When melting is complete, the heat-pipe tempera…

  • 32, Isotech 17702W Page 32 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) CALIBRATION APPARATUS FOR INDIUM AND TIN FIXED POINTS INTRODUCTION Before calibrating a standard platinum resistance thermometer, it is usual to check its water triple point resistance value and then to anneal the thermometer. The annealing temperature varies typically…

  • 46, Isotech 17702W Page 46 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) ACKNOWLEDGEMENT The Isotech dual furnace owes its origin to Dr. P. Marcarino of Italy. His research and development solved many of the problems of contamination and handling of high temperature thermometers. …

  • 9, Isotech 17702W Page 9 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) SAFETY CAUTIONARY NOTE Products of Isothermal Technology Ltd are intended for technically trained and competent personnel familiar with good laboratory practice. It is expected that personnel using this equipment will be knowledgeable and skilfu…

  • 26, Isotech 17702W Page 26 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) This PROGRAM has 7 segments. It shows the furnace instrument starting with a setpoint of 0.00°C • It is then set to RAMP to 150°C over a period of 120 minutes • It is then set to DWELL at this temperature for a period of 120 minut…

  • 7, Isotech 17702W Page 7 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) UNPACKING EVERY EFFORT HAS BEEN MADE TO PACKAGE THIS UNIT FOR TRANSPORT AND TO ENSURE ITS GOOD CONDITION ON ARRIVAL AT ITS DESTINATION. BEFORE COMMISSIONING IT IS NECESSARY TO REMOVE THE FURNACE CORE TRANSIT C…

  • 6, Page 6 of 48 Heatpipe Furnace Models 17702W, 17702P, 17702S (13–07/20) HEALTH AND SAFETY INSTRUCTIONS 1. Read this entire manual before use. 2. Wear appropriate protective clothing. 3. Operators of this equipment should be adequately trained in the handling of hot and cold items and liquids. 4. Do not u…

Similar Searches:
  • Isotech 17702W User Manual
  • Isotech 17702W User Guide
  • Isotech 17702W PDF Manual
  • Isotech 17702W Owner's Manuals

DOC-3c0da493:

Recommended:
Buddy Guy Standard Stratocaster, HDR-XR550V, HDC-861E, Kawasaki KFX400

AFFINITY PS8, 40", G Series, GRIZZLY FURNACE, GLUA Series, CARBOLITE GERO VST 12/600
  • NOTE: Read the entire instruction manual before starting theinstallation.TABLE OF CONTENTSSAFETY CONSIDERATIONS.....................................................1INTRODUCTION..........................................................................2ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONSPROCEDURE ................................................................................2CARE AND MAINTENANCE.....................................................2Cleaning and/or Replaci ...

    Model & Doc Type: 333BAV 12

  • Montpelier Surround Installation Instructionsfor use with the Montpelier Wood InsertThe Montpelier Wood Insert has several different sur-round options: Traditional Cast Surround, Small Cast Profile Surround, Bevel Cast Trim Surround, Steel Surround Panels, and Georgian Cast Surround. The in-stallation instructions for each are found in this manual. Locate the correct instructions for your model and proceed with the installation.NOTE: Cast iron parts can be heavy, an assistant would be a ...

    Model & Doc Type: Montpelier Wood Insert MEAD3BS 12

  • SSAAFFEETTYYWWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, andair-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or alteredequipment by an unqualified person could result in death or serious injury. When working on the equipmen ...

    Model & Doc Type: A801X026AM2SAB 56

  • OWNER'S OPERATION AND INSTALLATION MANUALFOR MODELS AGDV8, AGDV12, AGDV20GRAVITY DIRECT VENT WALL FURNACE WARNING: If the information in this Manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance.· Do not touch any electrical switch; do not use any phone in your building.· Immediately call your ...

    Model & Doc Type: AGDV8 24

Additional Information:

# Brand Model Document Type/File Pages File Size Last Checked
1 VERDER
CARBOLITE GERO RWF 12/23
36 23/08
2 ICP
N9MP1100F14A2
2 12/02
3 VERDER
CARBOLITE GERO HTF 17/10
70 15/01
4 Hastings
IST-100
27 02/09
5 COMFORT-AIRE
GUH96T
58 06/11
6 Barnstead
F62730
80 16/11
7 Pro-Fab Industries
Empyre Elite XT
32 21/12
8 Valor
737CN
23 1.52 Mb 15/10
9 Carrier
58DH
10 1.39 Mb 10/12
Popular Right Now:
# Brand Model Document (PDF) Pages Size Check Date
1 Renesas
Emulation Pod M3062NT3-RPD-E
86 0.91 Mb 27.08.2023
2 Cobra
iRADAR
2 0.68 Mb 08.09.2023
3 Yamaha
BT1100 2002
356 31.08.2023
4 Sony
UPD-X100
24 0.63 Mb 07.01.2024
5 Fluke
9140
52 0.53 Mb 27.11.2023
6 Regency
I31-LPG3
28 3.37 Mb 17.08.2023
7 Magnat Audio
Interior 5.1x
14 10.10.2023
8 Canon
imageclass LBP251dw
72 20.08.2023
9 Miller Electric
MTT-3512W
14 31.08.2023

Operating Impressions, Questions and Answers: