Specifications:261/261476-cdcfprb_owners_manual_and_installation_manual.pdf file (24 May 2023)
|
FMI CDCFpRB Indoor Fireplace PDF Owners Manual And Installation Manual (Updated: Wednesday 24th of May 2023 10:54:51 PM)
Rating: 4.4 (rated by 51 users)
Compatible devices: VSGF28NTF, VCD36RN, (V)S36 Series, (V)S42 SERIES, T32N-A, KC42N series, P324, S36 Series.
Recommended Documentation:
22, www.fmiproducts.com 124979-01C22 TROUBLESHOOTING …
4, www.fmiproducts.com 124979-01C4 PRODUCT IDENTIFICATION Ignitor Button Screen Fireplace Cabinet Log Control Knob Figure 1 - Vent-Free Compact Dual Flame Fireplace Hood Fireplace Cabinet Logs Ignitor Button Remote Control (Optional) Control Knob Hood OPTIONAL REMOTE CONTROL ACCESSORIES SAFETY Continued 5. Do not use this replace as a wood-burn- ing replace. Use only the logs provided with the replace. 6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using…
19, FMI CDCFpRB www.fmiproducts.com 124979-01C 19 • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 8. Slightly push in and turn control knob coun- terclockwise to the ON position. 9. Set ame adjustment knob to any level between HI and LO. 10. To leave pilot lit and shut off burners only, turn control knob clockwise to PILOT posi- tion. If using optional hand-held remote, use remote control m…
11, www.fmiproducts.com 124979-01C 11 INSTALLATION Continued 3. Install gas piping to replace location. This installation includes an approved exible gas line (if allowed by local codes) after the equipment shutoff valve. The exible gas line must be the last item installed on the gas piping. 4. If you have not installed hood, follow instructions on page 6. 5. Carefully set replace in front of rough opening with back of replace inside wall openi…
28, FMI CDCFpRB www.fmiproducts.com 124979-01C28 PARTS 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 Natural Gas Only 9 21 22 …
9, FMI CDCFpRB www.fmiproducts.com 124979-01C 9 INSTALLATION IMPORTANT: Vent-free replaces add mois- ture to the air. Although this is benecial, installing replace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6. Note: Your replace is designed to be used in zero clearance installations. Wall or framing ma- terial can be placed directly against any exterior surface on the rear, s…
26, www.fmiproducts.com 124979-01C26 8 8 14 14 14 14 14 14 14 1 9 10 10 16 17 10 6 3 11 12 13 11 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 19 PARTS …
10, www.fmiproducts.com 124979-01C10 WARNING: Maintain the minimum clearances shown If your replace is to be used with an optional mantel, the installation instructions incl…
7, www.fmiproducts.com 124979-01C 7 AIR FOR COMBUSTION AND VENTILATION Continued All spaces in homes fall into one of the three following ventilation classications: 1. Unusually Tight Construction 2. Unconned Space 3. Conned Space The information on pages 6 through 8 will help you classify your space and provide adequate ventilation. The air that leaks around doors and windows may provide enough fresh air for …
5, www.fmiproducts.com 124979-01C 5 LOCAL CODES Install and use replace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 State of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Com…
2, www.fmiproducts.com 124979-01C2 WARNING: Improper alteration, service or maintenance can cause - for correct installation and operational proce- additional information consult a qualified in- �…
16, www.fmiproducts.com 124979-01C16 WARNING: Read and fol- Installation should be done by WARNING: Do not connect this thermostat to any electrical �…
8, FMI CDCFpRB www.fmiproducts.com 124979-01C8 AIR FOR COMBUSTION AND VENTILATION Continued The space in the previous example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup- port. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconned space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air F…
3, FMI CDCFpRB www.fmiproducts.com 124979-01C 3 DANGER: Carbon monoxide Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be working properly. Have replace serviced. So…
27, www.fmiproducts.com 124979-01C 27 1 ** Outer Casing Top • 1 2 ** Bafe • 1 3 ** Outer Casing • 1 4 104281-02 Firebox Hood • 1 5 ** Firebox Top • 1 6 ** Firebox Wrapper • 1 7 ** Outer Base • 1 8 102635-02 Front Left and Right Sides • 2 9 103209-05 Extruded Louver • 2 10 098304-01 Screw, PPH AB 10-16 x 0.38 • 12 11 M10908-2 Screw, SLTD H…
23, FMI CDCFpRB www.fmiproducts.com 124979-01C 23 1. Control knob not fully pressed in 2. Control knob not pressed in long enough 3. Safety interlock system has been triggered 4. Equipment shutoff valve not fully open 5. Pilot flame not touching thermocouple, which al- lows thermocouple to cool, causing pilot ame to go out. This problem could be caused by one or both of the following: A) Low gas pre…
24, www.fmiproducts.com 124979-01C24 TROUBLESHOOTING Continued 1. Residues from manufac- turing processes and log curing 2. Not enough air 3. Gas regulator defective 1. Turning control knob to HI position when burner is cold 2. Air in gas line 3. Air passageways on re- place blocked 4. Dirty or partially clogged burner orice 1. When heated, vapors from furniture polish, wax, carpet …
14, www.fmiproducts.com 124979-01C14 INSTALLATION Continued We recommend that you install a sediment trap in supply line as shown in Figure 14, page 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into replace controls. If sediment trap is not installed or is installed wrong, replace may not run pro…
25, www.fmiproducts.com 124979-01C 25 TROUBLESHOOTING Continued …
21, www.fmiproducts.com 124979-01C 21 We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, …
Tutorial (EL-9900, #Y4H7EN)
EL-9900, 20, sharp/el-9900.pdf
Gateway SRX650 Instruction, #V4VX38
SRX650, 182, juniper/srx650.pdf
Cisco Switch Manual (#289A3P)
MDS 9216, 140, cisco/mds-9216.pdf
Crestron Gateway Manual (#6N91ND)
AM-200, 46, crestron/am-200.pdf
Scanner User Manual #K5F32V
8200 - ScanJet Digital Flatbed Scanner, 10, hp/8200-scanjet-digital-flatbed-scanner.pdf
Conference System User Manual #37AHA4
Room System SRS-Lync-XL, 2, smart/room-system-srs-lync-xl.pdf
INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-40-DEEP-XTBI-50-DEEP-XTBI-60-DEEP-XTBI-72-DEEP-XTBI-88-DEEP-XT SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity ...
BI-40-DEEP-XT 27
Tested by OMNI-Test Laboratories, Inc. and approved toUL 737-2011 and ULC S627-00US EPA exemptReport Number : 0304WF008SThis document was packed with the appliance.KEEP THESE INSTRUCTIONS FOR FUTURE USEEMIFOCUS____DESIGN INSTALLATION & OPERATING MANUAL ...
Emifocus 20
www.tsicustomerservice.com1-888-674-7517www.tsicustomerservice.comA6061Twin-Star International, Inc; Delray Beach, FL 33445Made in ChinaMODEL:DFI-5020-01, DFI-5020-02, DFI-5020-03DFI-5020-04, DFI-5020-05 ...
DFI-5020-01 12
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately.• Immediately call your gas supplier from a neigh-bor’s phone. Follow the gas supplier� ...
DRC6340TEP 56
CXF-705 Custom Embers Pan Burner 12028 E. Philadelphia St. Whittier , CA 90601 U.S.A. (562) 696-8718 FAX (562) 698-3510 [email protected] www.rasmussen.biz GENERAL INSTALLATION INSTRUCTIONS ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN VENTED CUSTOM EMBERS PAN BURNER MODELS: CXF for use with Natural Gas; CXFA for use w ...
CXF12 7
la verdadera llama para tu hogarBiochimeneaBio-ethanol FireplaceCheminée Bio ÉthanolBioethanol KaminLareira de BioetanolCaminetto a BioetanoloNB12Manual de instalaciónInstallation InstructionsManuel d’installationInstallationsanleitungManual de instalaçãoManuale d’installazione ...
Pur Line NB12 8
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Empire Comfort Systems | VFLB36FP30N |
28 | 03/07 | ||
2 | Somogyi | Home FKK 22 |
20 | 05/08 | ||
3 | CVO Fire | KARA |
38 | 18/09 | ||
4 | Duraflame | DFI-470-06 |
2 | 15/10 | ||
5 | Vermont Castings | WDV500NTSCSB |
68 | 19/06 | ||
6 | elco | P2.120 G |
44 | 08/08 | ||
7 | decorflame | M100-25FAO |
11 | 27/07 | ||
8 | Somogyi Elektronic | home FKK 14 |
28 | 05/10 | ||
9 | White Mountain Hearth | 21)L(N |
28 | 2.02 Mb | 01/07 | |
10 | Monessen Hearth | iLDV20NV |
40 | 25/06 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Philips | HP4600/00 |
2 | 0.23 Mb | 03.09.2023 | |
2 | jWIN | JV-TV7070 |
2 | 04.08.2023 | ||
3 | HP | D7171A - NetServer - LPr |
48 | 0.49 Mb | 07.09.2023 | |
4 | Belling | IB609FV |
20 | 30.09.2023 | ||
5 | Parkside | PNTS 1400 E2 |
36 | 04.09.2023 | ||
6 | Zanussi | ZDC 888 |
20 | 0.38 Mb | 05.08.2023 | |
7 | Saunier Duval | SYLVA FF 24 E |
16 | 0.47 Mb | 09.11.2023 | |
8 | Dell | OptiPlex GX110 |
69 | 08.09.2023 | ||
9 | Dixon | 966690603 |
60 | 26.06.2023 | ||
10 | D-Link | ShareCenter Pulse DNS-320 |
76 | 03.08.2023 |