Payne PH3G----A Manual, Product Data

Manual, Product Data for Payne PH3G----A Heat Pump (32 pages)

Specifications:

387/387857-ph3ga.pdf file (11 Oct 2023)
  • Manufacturer: Payne
  • Category of Device: Heat Pump
  • Document: PH3G----A, File Type: PDF Product Data
  • Updated: 11-10-2023
  • Count of Pages: 32
Download PH3G----A Manual (32 pages)

Read Payne PH3G----A Document Online:

Data: UPD 11th October 2023

Payne PH3G----A Heat Pump PDF Product Data (Updated: Wednesday 11th of October 2023 09:52:06 PM)

Rating: 4.2 (rated by 98 users)

Compatible devices: PH13NR, PH10, PA1P-B, PH2P-B Series, PH10JA, PH3Z, PH4G B Series, PH4GNAB24000AA.

Recommended Documentation:

Text Version of Payne PH3G----A Manual, Product Data (Summary of Contents)

(Ocr-Read of the Payne PH3G----A Document (Main Content), UPD: 11 October 2023)
  • 1, 1 Product Data P H 3 G -- -- A SINGLE PACKAGED HEAT PUMP SYSTEM WITH R--410A REFRIGERANT SINGLE AND THREE PHASE 2 -- 5 NOMINAL TONS (SIZES 24--60) A09183 Fig. 1 -- Unit PH3G----A Single--Packaged Products with Energy --Saving Features and R--410A refrigerant. S Up to 13.5 SEER S Up to 7.7 HSPF S Up to 11.5 EE…

  • 2, 2 TABLE OF CONTENTS FEATURES/BENEFITS 1............................... MODEL NUMBER NOMENCLATURE 2................. AHRI CAPACITIES 3.................................. PHYSICAL DATA 4................................... OPTIONS AND ACCESSORIES 5....................... BASE UNIT DIMENSIONS 7 --8....................…

  • 3, Payne PH3G----A 3 AHRI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT PH3G-- --A NOMINAL TONS STANDARD CFM COOLING CAPACITIES (Btuh) EER** SEER† 24 2 800 23,800 11.5 13.5 30 2-- 1/2 1000 29,000 11.5 13.5 36 3 1200 35,000 11.5 13.5 42 3-- 1/2 1400 40,000 11.5 13.2 48 4 1600 47,000 11.5 13.5 60 5 1850 57,000 11.5 13.5 HEAT …

  • 4, Payne PH3G----A 4 PHYSICAL DATA -- UNIT PH3G----A UNIT SIZE P H 3 G --- --- A 2 4 P H 3 G --- --- A 3 0 P H 3 G --- --- A 3 6 PH3G --- --- A42 P H 3 G --- --- A 4 8 P H 3 G --- --- A 6 0 NOMINAL CAPACITY (ton) 2 2.5 3 3.5 4 5 SHIPPING WEIGHT} (lb) (kg) 327 148 340 154 343 156 419 190 437 198 462 210 COMPRESSOR QUANTITY 1 TYPE SCRO…

  • 5, 5 OPTIONS AND ACCESSORIES ITEM DESCRIPTION FACTORY INSTALLED OPTION FIELD INSTALLED ACCESSORY Coil Options Base unit with tin plated indoor coil hairpins X Compressor Start Kit Compressor Start Kit assists compressor start ---up by providing additional starting torque on sing phase units only. X Corpor…

  • 6, Payne PH3G----A 6 ECONOMIZER COIL FILTER SIDE VIEW CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE BASE COIL FLANGE ON BASE DET AIL ECONOMIZER FI LTER EV APORATOR COIL TOP FILTER RACK BEND FLANGE AT 90° -SCREW TO DIVIDER WITH 1-IN. (25 mm) SCREW BOTTOM FILTER RACK DAMPER BLADE MANUAL OUTSIDE AIR HOOD REPLACEMENT PANEL ECO…

  • 9, 9 ROOF CURB ACCESSORY DIMENSIONS RETURN AIR SMALL BASE UNIT SUPPLY AIR LARGE BASE UNIT UNIT PLACEMENT ON COMMON CURB LARGE CURB SMALL OR LARGE BASE UNIT SMALL/COMMON CURB ROOF CURB DETAIL Wood nailer* Roofcurb* Insulation (field supplied) *Provided with roofcurb Cant strip field supplied Roofing material field sup…

  • 10, Payne PH3G----A 10 SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: Given: Required Cooling Capacity (TC) 34,500 Btuh.......... Sensible Heat Capacity (SHC) 26,000 Btuh............ Required Heating Capacity 60,000 Btuh............... Condenser Entering Air Temperature 9…

  • 11, Payne PH3G----A 11 PERFORMANCE DATA 24 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Cap…

  • 12, Payne PH3G----A 12 PERFORMANCE DATA (CONT) 30 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBt…

  • 13, Payne PH3G----A 13 PERFORMANCE DATA (CONT) 36 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l S…

  • 14, 14 PERFORMANCE DATA (CONT) 42 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sy…

  • 15, 15 PERFORMANCE DATA (CONT) 48 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBt…

  • 16, Payne PH3G----A 16 PERFORMANCE DATA (CONT) 60 Cooling Extended Performance Table EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.5) 115 (46.1) 125 (51.7) CFM / BF EWB _F(_C) Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW Capacity MBtuh Tota l Sys KW …

  • 17, Payne PH3G----A 17 LEGEND BF — Bypass Factor e d b — E n t e r i n g D r y --- B u l b Ewb — Entering Wet ---Bulb kW — Total Unit Power Input SHC — Sensible Heat Capacity ( 1000 Btuh) TC — Total C a pacity (1000 Btuh) (net) rh —Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of …

  • 18, Payne PH3G----A 18 PERFORMANCE DATA (CONT) Wet Coil Air Delivery (CFM)-- Downflow -- High Speed with 1--in. (25 mm) Filter and Economizer UNIT SIZE EXTERNAL STA TIC PRESSURE (IN. W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 36 1333 1289 1256 1214 1152 1118 1076 1035 997 950 42 1612 1569 1527 1481 1451 1393 1351 13…

  • 19, 19 Dry Coil Air Delivery* -- H orizontal and Downflow Discharge -- Unit PH3G----A24--60 UNIT MOTOR SPEED WIRE COLOR EXTERNAL STA TIC PRESSURE (IN. W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 P H 3 G --- --- A 2 4 Low Blue CFM 754 650 538 429 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- M e …

  • 20, 20 TYPICAL PIPING AND WIRING ROOF RETURN-AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) SUPPLY-AIR FLEXIBLE DUCT ROOF-MOUNTING CURB A09230 INDOOR THERMOSTAT DISCONNECT PER NEC* FROM POWER SOURCE RETURN AIR TOP COVER POWER ENTRY CONTROL ENTRY *NEC - National Electrical Code A09240 P…

  • 21, Payne PH3G----A 21 APPLICATION DATA Condensate trap — A 2 --in. (51 mm) condensate trap must be field supplied. Ductwork — Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge — Units are equipped with f…

  • 22, 22 ELECTRICAL DATA UNIT NOMINAL V-PH-HZ VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT POWER SUPPLY MIN MAX RLA LRA FLA FLA NOMINAL kW FLA MCA MOCP P H 3 G --- --- A 2 4 208/230-1-60 197 253 13.5 58.3 1.2 4.1 -/- -/- 22.2 30 3.8/5 18.1/20.8 44.8/48.2 45/50 5.4/7.2 25.9/30 54.6/59.7 60/60 7.5/10 36.1/41.7 67.3/74.3…

  • 23, 23 ELECTRICAL DATA (CONT) UNIT NOMINAL V-PH-HZ VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT POWER SUPPLY MIN MAX RLA LRA FLA FLA NOMINAL kW FLA MCA MOCP P H 3 G --- --- A 6 0 208/230-1-60 197 253 27.4 134 1.2 7.6 -/- -/- 43.1 60 3.8/5 18.1/20.8 65.7/69.1 70/70 5.4/7.2 25.9/30 75.4/80.6 80/90 7.5/10 36.1/41.7 …

  • 30, Payne PH3G----A 30 CONTROLS Operating sequence When power is supplied to unit, the transformer (TRAN) is energized. On units with crankcase heater, heater is also energized. Cooling — With the thermostat in the cooling position, the thermostat makes circuit “R” to “O”. This energizes the reversing valve solenoid (RVS) …

  • 31, 31 GUIDE SPECIFICATIONS Packaged Heat Pumps HVAC Guide Specifications Size Range: 2to5Tons,NominalCooling Model Number: P H 3 G -- -- A Part 1⎯General SYSTEM DESCRIPTION Outdoor, packaged,air--to --airheat pump unitutilizing a hermetic scroll compressor for cooling duty and optional electric heating. Unit sh…

  • 32, 32 GUIDE SPECIFICATIONS (CONT) L. Special Features Available: 1. Coil Options: Base unit with tin plated indoor coil hairpins. 2. Compressor Start Kit (single phase units only Shall provide additional starting torque for single--phase compressors. 3. Thermostat: To provide for two--stage heating and one--stage cooli…

DOC-9f986b97:

Recommended:
BL-C1A - Network Camera, SH-5512, PTS18SHSSS, 3300B002

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Panasonic
PAW-VP1000LDHW
134 16/01
2 Little Giant
1-ABS
4 27/12
3 GDH
G°CEL series
18 10/02
4 Ariston
NIMBUS COMPACT M NET 40 M EXT
88 21/11
5 Leader Evaporator
Half Pint Evaporator
20 09/10
6 Technibel
Liberty300 Solar
32 08/11

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Atlona
AT-HDWP
14 2.7 Mb 15.02.2024
2 PICO
PICO-2000
52 12.12.2023
3 Zodiac
RE/U
16 04.02.2024
4 A&D
UB-510
17 0.44 Mb 19.10.2023
5 NordicTrack
A.C.T. Commercial Plus
36 22.09.2023
6 CAT
Tmate
17 0.72 Mb 01.09.2023
Operating Impressions, Questions and Answers: