Gefen GEF-3GSDI-16416 Operation & User’s Manual

Operation & User’s Manual for Gefen GEF-3GSDI-16416 Switch (39 pages)

Specifications:

342/342520-gef3gsdi16416_user_manual.pdf file (12 Aug 2023)
  • Manufacturer: Gefen
  • Category of Device: Switch
  • Document: GEF-3GSDI-16416, File Type: PDF Operation & User’s Manual
  • Updated: 12-08-2023
  • Count of Pages: 39
Download GEF-3GSDI-16416 Manual (39 pages)

Read Document Online:

Data: UPD 12th August 2023

Gefen GEF-3GSDI-16416 Switch PDF Operation & User’s Manual (Updated: Saturday 12th of August 2023 08:08:28 AM)

Rating: 4.4 (rated by 80 users)

Compatible devices: RMT-MATRIX-444, EXT-HDMI1.3-442, 2x2 HDMI, DVI KVM DL, HDMI-441, DVI-444N, GTB-HD4K2K-441-BLK, EXT-DVI-841.

Recommended Documentation:

Text Version of Gefen GEF-3GSDI-16416 Manual (Summary of Contents)

(Ocr-Read of the Gefen GEF-3GSDI-16416 Document (Main Content), UPD: 12 August 2023)
  • 20, Gefen GEF-3GSDI-16416 17 RS-232 SERIAL CONTROL RS-232 Features RS-232 remote functions are used to control this product’s features. Features include input / output routing and reference signal functions . These features are available only through the use of the serial port. Functions Syntax The syntax for each function is always the same:…

  • 4, Gefen GEF-3GSDI-16416 1 Congratulations on your purchase of the 16x16 3GSDI Matrix. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies. Gefen’s reliable, plug-and-play products supplement cross-plat…

  • 13, Gefen GEF-3GSDI-16416 10 CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX Switching between RS-232 and RS-485 Protocols Press the ► button to display the serial interface selection screen: Use the ◄ or ► buttons to switch between RS-232 and RS-485 serial protocols. The current selection is indicated by the cursor. In the example above, RS-232 is the currentl…

  • 26, 23 Commands Command Description M Returns the current routing status of matrix R Routing command S Routes a single input to all outputs M Command The M command displays the current routing status of the matrix. Syntax: m Parameters: None R Command The R command allows specifi c routing of inputs and outputs. Syntax: r param1 param2 Parameters: param1 …

  • 15, 12 Displaying the Routing Status From the main screen, press the Select button. When the arrow cursor is next to OUTPUT, pressing the ◄ or ► buttons on the front panel will show the current routing state of each input and output. The example below shows that Input 1 is routed to Output 1. Pressing the ► button again will display the r…

  • 8, Gefen GEF-3GSDI-16416 5 PANEL DESCRIPTIONS Front Panel 1 LCD Display Displays the current routing status of the Matrix and is also used to manage source routing. 2 Power Switch Turn the power ON or OFF using this switch. 3 Control Buttons These buttons are used to navigate the LCD menu system. See pages 9 - 12 for more information. ◄ - Left ► - Rig…

  • 29, Gefen GEF-3GSDI-16416 26 IP CONTROL Masking The Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”. When an output is set to “Active”, it will function normally. When an output is set to “Mask”, it will not output any video. To set the “Active” or “Mask” …

  • 34, Gefen GEF-3GSDI-16416 31 WARNING MESSAGES System Failure In the case of a critical malfunction, the following warning message will be displayed on the Main Display: If the 16x16 3GSDI Matrix is connected to a PC using a terminal program, the following message will appear on the display: System failure !!! Power-down the Matrix immediately and contact Gefen Technical Support…

  • 30, 27 IP CONTROL IP Confi guration The IP Confi guration page is used to set the IP settings that will be used to access the Web interface. The following items can be confi gured from this menu. • IP Address (Default: 192.168.0.70) • Subnet (Default: 255.255.255.0) • Gateway (192.168.0.1) • Port (Default: 80) • • To change these …

  • 28, Gefen GEF-3GSDI-16416 25 IP CONTROL The GefenPRO 16x16 3GSDI Matrix supports IP-based control using an integrated Web interface. To access this feature, an IP address, subnet, gateway, and port number need to be set on the 16x16 3GSDI Matrix (Default IP: 192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.168.0.1 Port: 80). Consult the network…

  • 35, Gefen GEF-3GSDI-16416 32 RACK MOUNT SAFETY INFORMATION a. Maximum recommended ambient temperature: 45 ˚C b. Increase the air fl ow to maintain the temperature inside the rack. c. Install the product evenly to avoid mechanical overload. d. Connect an earthing wire between the an earthing stud and the grounding pin on the chassis. …

  • 21, Gefen GEF-3GSDI-16416 18 RS-232 SERIAL CONTROL #PRREFTABLE Function The #PRREFTABLE function displays the Reference In data table (timings) which are recognized by the 16x16 3GSDI Matrix. Syntax: #PRREFTABLE Parameters: None IP Confi guration Functions Function Description #ISPADD Sets the IP Address #SNETMASK Sets the Net Mask #SGATEWAY Se…

  • 10, 7 PANEL DESCRIPTIONS Back Panel 1 Reference In Connector Connect an external reference to this connector. Bi-level (black burst) and tri- level sync are supported. 2 3G-SDI Output Ports (1 - 16) Connect 3G-SDI monitors to these ports. 3 Grounding Terminal Provides a discharge path to ground in case a short circuit occurs between the “hot�…

  • 36, 33 Input / Output • SDI (SMPTE 259MI up to 360 Mbps) • HD-SDI (SMPTE 292M up to 1.485 Gbps) • 3G-SDI (SMPTE 424M/425M up to 3.0 Gbps) Supported Formats......................................................All SD, HD, and 3G formats Maximum Resolution...........................................................1080p, 1920x1200, 2K Inpu…

  • 32, 29 FIRMWARE UPDATE Firmware Update Procedure To Begin the update procedure the unit’s Boot Loader must be activated. To activate the Boot Loader please follow the procedure below: If the unit is already powered on, the following RS-232 command can be used to activate the Boot Loader: 1. Connect RS-232 cable to PC and activate a terminal program. 2. …

  • 22, Gefen GEF-3GSDI-16416 19 RS-232 SERIAL CONTROL #SNETMASK Function The #SNETMASK function specifi es a new net mask. Syntax: #SNETMASK param1 param2 param3 param4 Parameters: param1 Net mask [0 - 255] param2 Net mask [0 - 255] param3 Net mask [0 - 255] param4 Net mask [0 - 255] Notes: A reboot is required after using this function. #SGATEWAY Fun…

  • 38, Gefen GEF-3GSDI-16416 35 LICENSING lwIP is licenced under the BSD licence: Copyright (c) 2001-2004 Swedish Institute of Computer Science. All rights reserved. Redistribution and use in source and binary forms, with or without modifi cation, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the ab…

  • 27, Gefen GEF-3GSDI-16416 24 RS-232 SERIAL COMMANDS S Command The S command routes a single input to all 16 3GSDI outputs. Syntax: s param1 Parameters: param1 Input [1 - 16] Notes: Setting param1 to a value of 0 will place the matrix in one-to-one mode. This means that Input 1 will be routed to Output 1, Input 2 will be routed to Output 2…

  • 25, 22 RS-232 SERIAL CONTROL #RMTIRADD Function The #RMTIRADD function set the remote IR channel. Syntax: #RMTIRADD param1 Parameters: param1 IR channel [0 - 3] #RSTIP Function Sets IP confi guration to default (192.168.0.70) Syntax: #RSTIP Parameters: None Notes: This command requires the unit to be rebooted in order to take effect. …

  • 3, CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 4 Front Panel 5 Front Panel Descriptions 6 Panel Layout 6 Back Panel 7 Back Panel Descriptions 8 Connecting And Operating The 16x16 3GSDI Matrix 8 Wiring Diagram 9 The Standby Screen 9 Displaying the Firmware Version 9 Displaying the Boot Loader …

  • 16, Gefen GEF-3GSDI-16416 13 IR REMOTE DESCRIPTION RMT-16416IR Remote Control Unit 1 Activity Indicator This LED will be activated momentarily each time a button is pressed. 2 Display and Source Selection Buttons (1 - 16) These buttons are used to select which source is routed to a monitor. Routing sources using the Remote Control unit Issuing a routing command is a two step p…

Similar Searches:
  • Gefen GEF-3GSDI-16416 User Manual
  • Gefen GEF-3GSDI-16416 User Guide
  • Gefen GEF-3GSDI-16416 PDF Manual
  • Gefen GEF-3GSDI-16416 Owner's Manuals

DOC-fa063572:

Recommended:
ThinkCentre E51, CDDS60, C15F27, AT-8600 Series

ZSE30AF-#-#-X576, Pro 21 7756 34/47, DES-3550, U460-002-2AM-C, CA19
  • 60264 Weichenmodul für KATO und Rokuhan Weichen Switch Module for KATO and Rokuhan SwitchesMithilfe dieses Weichenmoduls können Sie H0- und N-Weichen von KATO sowie Z-Weichen von ROKUHAN über herkömmliche, analoge Stellpulte wie z. B. Märklin ® Weichenstellpult (Art.-Nr. 72720) ansteuern und schalten. Anleitung beachten! With the aid of this Switch Module you can control and operate H0 and N scale ...

    Model & Doc Type: 60264 2

  • L1V30487857614-013ZW1012-0VW00-2BA0sOperating Instructions Betriebsanleitung Notice d'utilisation Instructivo Istruzioni operativeInstruções de Serviço İşletme kılavuzu Руководство по эксплуатации Instrukcja obsługi 使用说明ENDANGERHazardous voltage. Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. Replace all covers before power supplying this de ...

    Model & Doc Type: 3VW9011-0AT11 4

  • Hub 3.0 InstallationInstructionsUser InterfaceA. Wi-Fi Button – To Reset the Wi-Fi credentials of the LeakSmart Hub 3.0.B. Power ON/OFF – A Switch to turn ON/ turn OFF the LeakSmart Hub 3.0.Note: Battery is only backup supply. User must use power adapter in order to switch ON the device.C. Factory Reset – Factory reset the LeakSmart Hub 3.0.Note: All the paired sensor devices will be removed after factory reset.D. Use ...

    Model & Doc Type: Hub 3.0 7

  • HYDROMETER GmbH Industriestraße 13 · 91522 Ansbach · Telefon +49 (981) 18 06 - 0 · Telefax +49 (981) 18 06 – 615 Am Weimarer Berg 3 · 99510 Apolda/Thüringen · Telefon +49 (3644) 84 33 - 0 · Telefax +49 (3644) 84 33 - 411 [email protected] · www.hydrometer.de · Subject to technical adjustments · 12.05.2011 1 IZAR CENTER 60/120/250 | IZAR CENTER 60/120/250 Memory Installation 157,5 mm68 66 67 29 30 31 32 33 34 1 2 ...

    Model & Doc Type: IZAR CENTER 60 3

Additional Information:

# Brand Model Document Type/File Pages File Size Last Checked
1 Cisco
SR2024 - Small Business Unmanaged Switch
36 2.03 Mb 07/02
2 Intellisystem
IT-3000-OCT
2 26/02
3 United Technologies
Interlogix UltraSync
64 26/09
4 schmersal
IFL 333
2 18/08
5 Manhattan
161077
2 18/08
6 Advantech
EKI-2525M
30 0.71 Mb 03/12
7 Dell
PowerEdge M1000e
103 10.66 Mb 21/11
8 LevelOne
FEU-0511
17 13/10
9 Extron electronics
SW8/12 VGA Ars
1 01/12

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 LevelOne
WAP-0005
94 26.09.2023
2 Panasonic
TH-42PY70F
22 21.12.2023
3 Crestron
TPMC-10-DS
2 0.19 Mb 05.11.2023
4 Dell
PowerVault 51F
38 0.47 Mb 02.11.2023
5 Element
ELCFT191
27 9.34 Mb 14.02.2024
6 Generac Power Systems
3500XL
20 0.77 Mb 11.02.2024
7 Bosch
AKE 30 S
15 22.08.2023
8 ChefScape
4-SLOT EGG & MUFFIN TOASTER
40 0.47 Mb 06.12.2023
9 PEUGEOT
106 2001
107 09.10.2023

Operating Impressions, Questions and Answers: