Desa 6000 BTU/HR Owner's Operation And Installation Manual

Owner's Operation And Installation Manual for Desa 6000 BTU/HR Gas Heater, Heater (20 pages)

Specifications:

651/651905-6000_btuhr.pdf file (01 Nov 2023)
  • Manufacturer: Desa
  • Category of Device: Gas Heater, Heater
  • Document: 6000 BTU/HR, File Type: PDF Owner's Operation And Installation Manual
  • Updated: 01-11-2023
  • Count of Pages: 20
Download 6000 BTU/HR Manual (20 pages)

Read Desa 6000 BTU/HR Document Online:

Data: UPD 1st November 2023

Desa 6000 BTU/HR Gas Heater, Heater PDF Owner's Operation And Installation Manual (Updated: Wednesday 1st of November 2023 02:29:10 PM)

Rating: 4.5 (rated by 10 users)

Compatible devices: HL18N, CDR3924PT, CGS2718N, CGB3924NR, LSL3124N, VRL24NR, VF-24N-PJD, CANADIAN PROPANE CONSTRUCTION CONVECTION HEATER.

Recommended Documentation:

Text Version of Desa 6000 BTU/HR Owner's Operation And Installation Manual (Summary of Contents)

(Ocr-Read of the Desa 6000 BTU/HR Document (Main Content), UPD: 01 November 2023)
  • 1, Desa 6000 BTU/HR Save this manual for future reference. ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance…

  • 2, Desa 6000 BTU/HR 2 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR SAFETY INFORMATION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serv…

  • 3, 3 103112 OWNER’S MANUAL PRODUCT IDENTIFICATION PRODUCT FEATURES Safety Pilot This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. Piezo Ignition System This h…

  • 4, 4 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Secti…

  • 5, 5 103112 OWNER’S MANUAL Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Figure 2 - Ventilation Air from Inside Building AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air …

  • 6, 6 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR 2. Mark two mounting screw locations on wall (see Figure 5). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater. WARNING: Maintain minimum clearances shown in Figure 5. If you can, provide greater clear-…

  • 7, 7 103112 OWNER’S MANUAL Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. In…

  • 8, 8 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce inco…

  • 9, 9 103112 OWNER’S MANUAL CHECKING GAS CONNECTIONS PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 Psig will damage heater regulator. 2. Cap off open …

  • 10, Desa 6000 BTU/HR 10 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR Shutting Off Heater 1. Turn control knob clockwise Clockwise to the PILOT position. 2. Press in control knob and turn clock- wise Clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to …

  • 11, 11 103112 OWNER’S MANUAL If pilot flame pattern is incorrect, as shown in Figure 19 • turn heater off (see To Turn Off Gas to Appliance, page 10) • see Troubleshooting, pages 12 through 14 Thermocouple Pilot Burner Figure 19 - Incorrect Pilot Flame Pattern GRH/OV 008BAD PILOT/LP BURNER FLAME PATTERN Figure 2…

  • 12, 12 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar o…

  • 13, 13 103112 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit REMEDY 1.…

  • 14, 14 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas …

  • 15, Desa 6000 BTU/HR 15 103112 OWNER’S MANUAL Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot sup- ply original replacement part(s), call DESA Internat…

  • 16, Desa 6000 BTU/HR 16 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW 12-2 12-1 ODS/PILOT VP600B ILLUSTRATED PARTS LIST …

  • 17, Desa 6000 BTU/HR 17 103112 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. PARTS LIST KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembly (VP600…

  • 18, Desa 6000 BTU/HR 18 103112 VENT FREE PROPANE/LP GAS HEATER BLUE FLAME 6000 BTU/HR NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ __________________________________________…

  • 19, Desa 6000 BTU/HR 19 103112 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ __________________________________________________________________________________…

  • 20, KEEP THIS WARRANTY WARRANTY INFORMATION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Se…

DOC-5aeed14c:

Recommended:
Saw Blade, EB19AKXL, S24C450D, 6823

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 IHP
(C)(GC)IR6PMA series
28 30/10
2 Astria
Sheridan18NM
32 10/02
3 Detroit Radiant Products
FA series
56 24/10
4 Truma
VarioHeat
100 29/09
5 Clarke
MGH1
16 03/10
6 Comfort Glow
GLD1856T
32 31/08
7 Empire
RH-25-5
12 21/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Ultra Products
USB 2.0 Floppy Disk Drive/All in One Card Reader
6 1.87 Mb 31.10.2023
2 MRV Communications
NH2025-10
86 29.11.2023
3 Panasonic
SC-BT105
48 27.12.2023
4 Omron
Walking style IV
22 05.01.2024
5 FujiFilm
SonoSite iViz
60 01.01.2024
6 Kenwood
K31GSS10
32 28.10.2023
7 Hisense
RS-17DR1SS
28 28.12.2023
8 Maytag
12001908
3 13.02.2024
Operating Impressions, Questions and Answers: