Mitsubishi PUHZ-W112VHA Service Manual

Service Manual for Mitsubishi PUHZ-W112VHA Heat Pump (46 pages)

Specifications:

1138/1138070-puhzw112vha.pdf file (21 Dec 2023)
  • Manufacturer: Mitsubishi
  • Category of Device: Heat Pump
  • Document: PUHZ-W112VHA, File Type: PDF Service Manual
  • Updated: 21-12-2023
  • Count of Pages: 46
Download PUHZ-W112VHA Manual (46 pages)

Read PDF Document Online:

Data: UPD 21st December 2023

Mitsubishi PUHZ-W112VHA Heat Pump PDF Service Manual (Updated: Thursday 21st of December 2023 10:54:27 AM)

Rating: 4.1 (rated by 73 users)

Compatible devices: PKA-A12HA6, MUZ-GB50VA, HEAT PERFORMER Premium Comfort Series, PUHZ-W*HA series, EHST20C-VM2C, PUHZ-W50VHA, PUHZ-W85VHA2.UK, Mr. Slim NH33NBD.

Recommended Documentation:

Text Version of Mitsubishi PUHZ-W112VHA Heat Pump Manual (Summary of Contents)

(Ocr-Read of Mitsubishi PUHZ-W112VHA Document (Main Content), UPD: 21 December 2023)
  • 1, SERVICE MANUAL AIR TO WATER HEAT PUMP No. OCH562 CONTENTS 1. SAFETY PRECAUTION ................................... 2 2. SPECIFICATIONS ............................................ 5 3. DATA ............................................................... 7 4. OUTLINES AND DIMENSIONS ...…

  • 28, 28 Main body Lead wire Stopper Coil Be sure to attach the stopper. A (3) How to attach and detach the coil of linear expansion valve <Composition> Linear expansion valve is separable into the main body and the coil as shown in the diagram below. <How to detach the coil> …

  • 23, 23 8-4. HOW TO CHECK THE PARTS PUHZ-W112VHA PUHZ-W112VHA-BS 1 2 3 4 5 M Gray Orange Red Yellow Black Parts name Check points Disconnect the connector then measure the resistance with a tester. (At the ambient temperature of 10 to 30:) TH3: Liquid pipe temp. TH4: Discharge temp. TH6…

  • 31, 31 8-7. OUTDOOR UNIT OPERATION MONITOR FUNCTION SW2 setting 1 ON 2 3 4 5 6 Display detail Explanation for display Unit Operation indicator SW2: Indicator change of self diagnosis <Digital indicator LED3 working details> (Be sure that the 1 to 6 in the SW2 are set to OFF.) (1) Display whe…

  • 30, Mitsubishi PUHZ-W112VHA 30 CNAC1, CNAC2 230 V AC Connect to the out- door controller circuit board (CNAC) NI, LI Voltage of 230 V AC is input (Connect to the terminal block (TB1)) EI, E4 Connect to the earth DCL1, DCL2 Connect to DCL P2 Connect to the smooth- ing capacitor CB + U/V/W Connect to the compre…

  • 12, 12 REFRIGERANT SYSTEM DIAGRAM7 Distributor TH7 Strainer(#100) Strainer(#100) Receiver Power LEV-B TH6 TH32 Plate HEX Water IN Water OUT Strainer (#100) TH3 STOP VALVE CHECK/V CHECK/V H/P SW L/P SW TH4TH33 TH34 TH8 P/B LEV-A COMP REV/V P-Sensor Strainer (#100) Strainer (#100) MUFFLER …

DOC-f858521a:

Recommended:
6LR61, AEROPRO H930, GeForce GTX 580 3072MB Hydro Copper 2, SPA921 - Cisco - IP Phone

PUMY-P VHMB, Z300, ECLI15MA, advance s, W7620
  • IMPORTANT SAFETY INSTRUCTIONSThe following symbols and labels are used throughout thismanual to indicate immediate or potential safety hazards. It isthe owner’s and installer’s responsibility to read and comply withall safety information and instructions accompanying these sym-bols. Failur ...

    Model & Doc Type: AVZC20 48

  • 5838219 GB 2/2019Dispose after installation.Installation instructionsfor contractorsVIESMANNReplacing the distilled water cartridge, air filter, airfilter B and CO sensor (5-yearly service pack)for Vitovalor PT2 and PA2Safety instructionsPlease follow these safety instructions cl ...

    Model & Doc Type: Vitovalor PA2 12

  • PUMY-P VHMB(-BS)OUTDOOR UNITS SeriesSpecificationsPower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range of heatingIndoor unitconnectableSound pressure level (measured in anechoic room)Diameter of refrigerant pipeExternal finishExternal dimension H ✕ W � ...

    Model & Doc Type: PUMY-P VHMB 3

  • SPLIT-TYPE, HEAT PUMP AIR CONDITIONERSSERVICE MANUALR32Outdoor unit[Model Name]PUZ-M200YKAPUZ-M250YKA[Service Ref.]PUZ-M200YKA.UKPUZ-M250YKA.UKPARTS CATALOG (OCB737)CONTENTS1. REFERENCE MANUAL ···························· 22. SAFETY PRECAUTION ··········� ...

    Model & Doc Type: PUZ-M200YKA 110

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Riello
VegA RMXA Series
24 26/11
2 Bryant
Preferred Series
44 15/11
3 Airwell
DAF009
171 29/01
4 Johnson Controls
R-410A
14 07/12
5 ACDC
SDAW4.6-220
29 16/04
6 Daikin
EKCBX008BBV3
24 03/02
7 Alpha-InnoTec
HMD 1/E
36 23/11
8 Viessmann
Vitocal 222-S
156 10/11
9 ARAMA
DCIPT9
16 07/10
10 Daikin
VRV IV-S Series
536 27/02

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Delfield
UC4460N
2 10.01.2024
2 Amazing Machinery
Performance Gas Engine
14 07.01.2024
3 SOLE
R92
30 5.5 Mb 06.11.2023
4 Ever
Superline 6k
41 18.03.2024
5 Monacor
TVCCD-700COL
58 17.12.2023
6 Hitachi
CP-X255
2 0.81 Mb 28.11.2023
7 Chicago Electric
42818
15 0.55 Mb 19.04.2024
8 KTI Networks
KSC-240
43 20.10.2023
9 Black Box
38891
3 0.26 Mb 31.10.2023
10 Jet
J-7040
32 17.10.2023
Operating Impressions, Questions and Answers: