Endress+Hauser iTEMP TMT162 Manual, Technical Information

Manual, Technical Information for Endress+Hauser iTEMP TMT162 Measuring Instruments, Transmitter (24 pages)

Specifications:

946/946869-itemp_tmt162.pdf file (28 Nov 2023)
  • Manufacturer: Endress+Hauser
  • Category of Device: Measuring Instruments, Transmitter
  • Document: iTEMP TMT162, File Type: PDF Technical Information
  • Updated: 28-11-2023
  • Count of Pages: 24
Download iTEMP TMT162 Manual (24 pages)

Read PDF Document Online:

Data: UPD 28th November 2023

Endress+Hauser iTEMP TMT162 Measuring Instruments, Transmitter PDF Technical Information (Updated: Tuesday 28th of November 2023 01:12:52 PM)

Rating: 4.6 (rated by 91 users)

Compatible devices: Proservo NMS80, Liquiline M CM42, Proline 500, Proline Promass 80, easytemp TSM 470 G, Gammapilot M FMG50, Proline Promass 80S, Soliwave FQR56.

Recommended Documentation:

Text Version of Endress+Hauser iTEMP TMT162 Measuring Instruments, Transmitter Manual (Summary of Contents)

(Ocr-Read of Endress+Hauser iTEMP TMT162 Document (Main Content), UPD: 28 November 2023)
  • 14, TMT162 14 Endress+Hauser Mechanical construction Design, dimensions Dimensions in mm (inch) T09-TMT162ZZ-06-00-xx-xx-001 Die-cast aluminum housing for general purpose or, as option, stainless steel housing (316L) * Dimensions without display = 4.41" (112 mm) T09-TMT162ZZ-06-00-xx-en-003 Opti…

  • 17, TMT162 Endress+Hauser 17 CSA (Canadian Standard Association) Explosion-proof, Dust ignition-proof Mark: Class I, Zone 1, Ex d IIC: Class I, Div. 1, Groups A, B, C & D; Class II, Div. 1 Groups E, F & G; Class III Connection data: Intrinsical Safety Mark: Ex ia IIC: Class I, Div. 1, G…

  • 1, TI086R/24/ae/03.09 Technical Information iTEMP ® TMT162 Temperature field transmitter with HART ® , FOUNDATION™ Fieldbus or PROFIBUS ® PA protocol Application • Input: RTD, TC, Ω, mV •Output: – HART protocol for converting various input signals to a scalable 4 to 20 mA analo…

  • 11, TMT162 Endress+Hauser 11 Sensor transmitter matching Resistance thermometers have high linearity. However, every sensor has an individual temperature resistance characteristic curve. This characteristic curve must be described as accurately as possible in order to achieve a high level of accurac…

  • 19, Endress+Hauser iTEMP TMT162 TMT162 Endress+Hauser 19 Ordering information Product structure TMT162 iTEMP ® TMT162, Field transmitter, Temperature transmitter; Application: RTD, TC, Ohm, mV; 2-wire 4...20 mA; galvanic isolation; NEMA 4x, IP67; Dual compartment; GL (German Lloyd) Marine (HART ® device only); UL li…

  • 13, TMT162 Endress+Hauser 13 Degree of protection • Aluminum die-cast or stainless steel housing: IP67, NEMA 4X • Stainless steel housing for hygienic applications (T17 housing): IP66/IP68 (1.83 m H 2 O for 24 h), NEMA 4X, NEMA 6P Shock and vibration resistance 3g / 2 to 150 Hz as pe…

DOC-dceddd00:

Recommended:
SBX-B30, MGS5752BDW19, THINKPAD T30, P-5611-B

JFR-2 Series, PluraSens E2658-VOC, OmniiCopper Vi27000 Series, CMD5B4 Series, Bike Pod
  • Pg. 2 HOW IT WORKS 3 MOUNTING 3 CODE SWITCH SETTINGS 3 BATTERY BACKUP 3 TRANSMITTER FUNCTION SWITCH SETTINGS 3 INDICATOR LEDS 4 TEST BEACON 4 BASIC PIVOT INSTALLATION 5 REINKE PIVOTS 6 VALLEY 4000, 6000, AND PANELS WITH 3 SEC DELAY PCB. 7 VALLEY 8000, PRO PANEL ...

    Model & Doc Type: 810-T 14

  • MODEL RANGE Switch S4 MIRRORSelectorDT-906 61 m (200')OPEN* 200' *DT-906 37 m (120')CLOSED 120' DT-900 27 m (90') OPEN* 90' * DT-900 15 m (50') CLOSED 50' SENSITIVITY S3 HIGHHNORMAL N* LOW L** DT·900 Series DUAL TEC® Motion Sensor for Commercial ...

    Model & Doc Type: DT906 2

  • Application Drawing Vi27000/Vi27001 Single-Pair Ethernet & PoE Transmission Solution Installation ManualDO NOT OPENRISK OF ELECTRIC SHOCKCAUTIONCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,DO NOT REMOVE COVER. NO USER SERVICEABLEPARTS INSIDE. REFER SERVICING TO QUALIFIEDSERVICE PERSO ...

    Model & Doc Type: OmniiCopper Vi27000 Series 2

  • www.rosemount.com¢00825-0100-4725.¤Quick Installation Guide00825-0100-4662, Rev CBJuly 2011Rosemount 8732StartStep 1: Pre-InstallationStep 2: HandlingStep 3: MountingStep 4: Installation (Flanged Sensors)(Wafer Sensors)(Sanitary Sensors)Step 5: GroundingStep 6: WiringStep 7: Basic ...

    Model & Doc Type: 8732E 60

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Broadata Communications
LINKBRIDGE LBC-HDV-T
42 12/10
2 DMP Electronics
1106
4 15/11
3 RKI Instruments
65-2640RK-05-04
57 13/02
4 LD
WATS 1
4 12/01
5 Listen Technologies
LT-800
24 08/02
6 CYP
CH-1107 TX
10 09/12
7 Conductix-Wampfler
ProfiDAT Programm 0514
82 04/03
8 Vaisala
HMT140
20 01/02
9 Sony
WRT-8P
19 27/03
10 Comnet
FVT80D4SFP
6 29/11

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Fanimation
FP4210
2 0.19 Mb 22.12.2023
2 Enterasys
Matrix E1 1G694-13
244 2.01 Mb 16.11.2023
3 Valor
Legend G3.5 700IN
46 13.03.2024
4 LG
LS240HEV
3 18.12.2023
5 Panasonic
CQDP171U - AUTO RADIO/CD DECK
48 31.01.2024
6 YORKVILLE
M8
22 4.78 Mb 16.02.2024
7 VKI Technologies
Eccellenza Café
88 6.3 Mb 30.11.2023
8 Blanco
Precision Microedge Sink 516196
1 0.19 Mb 11.02.2024
9 Sony
Xplod CDX-GT430IP
30 4.97 Mb 27.01.2024
10 Toshiba
D-KR4
52 1.35 Mb 09.02.2024
Operating Impressions, Questions and Answers: