Mitsubishi PUMY-P60NKMU Technical Service Manual

Technical Service Manual for Mitsubishi PUMY-P60NKMU Air Conditioner (114 pages)

Specifications:

927/927412-pumyp60nkmu.pdf file (17 Dec 2023)
  • Manufacturer: Mitsubishi
  • Category of Device: Air Conditioner
  • Document: PUMY-P60NKMU, File Type: PDF Technical Service Manual
  • Updated: 17-12-2023
  • Count of Pages: 114
Download PUMY-P60NKMU Manual (114 pages)

Read PDF Document Online:

Data: UPD 17th December 2023

Mitsubishi PUMY-P60NKMU Air Conditioner PDF Technical Service Manual (Updated: Sunday 17th of December 2023 08:02:10 PM)

Rating: 4.3 (rated by 55 users)

Compatible devices: PKFY-P30NKMU-E2, PUHZ-SHW80YAA, SRK18CL, SRK20ZJ-S, FR-A721-11K, Mr.Slim MS24WN, PWFY-P36NMU-E-BU, PEA-RP200.

Recommended Documentation:

Text Version of Mitsubishi PUMY-P60NKMU Air Conditioner Manual (Summary of Contents)

(Ocr-Read of Mitsubishi PUMY-P60NKMU Document (Main Content), UPD: 17 December 2023)
  • 30, 30 8-1-2. Special Function Operation and Settings (for M-NET Remote Controller) • It is necessary to perform “group settings” and “paired settings” at making group settings of different refrigerant systems (multiple outdoor unit). (A) Group settings: Enter the indoor unit controlled by th…

  • 101, 101101 9-3. DESIGN FOR CONTROL WIRING Please note that the types and numbers of control wires needed by the CITY MULTI-S series will depend on the remote con- trollers and whether they are linked with the system. 9-3-1. Selection number of control wires 9-3-3. M-NET Remote controller wiring 9-…

  • 70, Check code Abnormal points and detection methods Causes and check points Abnormal if the data of unit/transmission processor were not normally transmitted. Abnormal if the address transmission from the unit processor was not normally transmitted. Accidental disturbance such as noise or…

  • 34, Check code Abnormal points and detection methods Causes and check points (1) Abnormal if TH4 falls into following temperature conditions; ●exceeds 110 [230 °F]continuously for 5 minutes ●exceeds 125 [257 °F] (2) Abnormal if a pressure detected by the high-pressure sensor an…

  • 57, Mitsubishi PUMY-P60NKMU Check code Abnormal points and detection methods Causes and check points Abnormal if no rotational frequency is detected, or detected a value outside the specifi ed range during fan motor operation. Malfunction of fan motor Disconnection of CNF connector Defective outdoor cont…

  • 43, Check code 1500 Superheat due to low discharge temperature trouble Abnormal points and detection methods Causes and check points Abnormal if the discharge superheat is continuously detected less than or equal to −15 [5 °F]* for 5 minutes even though the indoor LEV has minimum open pulse…

DOC-90848d22:

Recommended:
FWC87037, ESGS, LIFT, HTS7200/12

SW-35-65E, Styler S3 F Series, APAC100W, LW1210HR, MSZ-YK09VA-H1
  • Product No. FAA055N7A1 FAA055N7A2 Series MS II MS II Volts 115 115 BTU-Cooling 5200 5200 Owner's Guide 2202039823 2202039823 Market North America North America M40L0002.eps M40C0002.eps M40M0001.eps Remote Control wiring diagram.eps ELECTROLUX HOME PRODUCTS ...

    Model & Doc Type: FAA055N7A 6

  • 1Please observe the following instructions.1. Operate the Power button to run or stop the unit.- Do not operate Main Power Switch or Auxiliary Power Switch to do it.2. Do not stick anything into the air outlet or inlet.- It is a danger and it can cause trouble.3. You must frequently ...

    Model & Doc Type: DWA-182R 18

  • USER’S MANUALAIR-CONDITIONERRLC012A002ADXK09Z5-SDXK12Z5-SDXK15Z5-SAIR-CONDITIONING & REFRIGERATION DIVISION3-1, Asahi, Nishibiwajima-cho, Kiyosu, Aichi, 452-8561, Japanhttp://www.mhi.co.jpMITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.7 Roundwood Avenue, Stockley Park, Uxbridge, M ...

    Model & Doc Type: DXK09Z5-S 24

  • ProductData 38BRC (60 Hz)Air Conditioner Sizes 024 thru 060 Copyright 2000 Carrier Corporation Form 38BRC-9PD Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most de ...

    Model & Doc Type: 38BRC 24

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Haier
HD301
24 7.81 Mb 16/10
2 York
SUNLINE MAGNADRY WR 180
56 3.63 Mb 16/03
3 LG
LW-C1262QC
24 16/04
4 Kooltronic
Large Horizontal Top-Mounted Series
14 15/02
5 Yamato
optimum YW09H1/I
32 22/01
6 Mitsubishi Electric
PLA-A12BA4
44 27/11
7 Pfannenberg
DTS 3000 Series
48 23/03
8 International comfort products
DLFSFA
14 07/10
9 Junliye
JLY530
14 12/11
10 Daikin
FCQ18PAVJU
11 0.53 Mb 14/03

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Medtronic
Serena Quad CRT-P MRI SureScan W4TR05
48 11.11.2023
2 JVC
LT-19HA22U
27 04.12.2023
3 Singer
400W1
44 8.6 Mb 31.12.2023
4 Acer
AL702
16 0.31 Mb 29.03.2024
5 Xerox
Phaser 6300
120 16.12.2023
6 Zanussi
534324
6 0.27 Mb 21.03.2024
7 Wincor Nixdorf
BEETLE
28 07.04.2024
8 Biamp
PMX84
25 12.12.2023
9 Nuvo
T2FAM-EX
2 22.03.2024
10 Shure
PSM 400
19 22.12.2023
Operating Impressions, Questions and Answers: