Mitsubishi Electric CMB-WP-V-GA1 Manual, Data Book

Manual, Data Book for Mitsubishi Electric CMB-WP-V-GA1 Air Conditioner (192 pages)

Specifications:

927/927311-cmbwpvga1.pdf file (20 Mar 2024)
  • Manufacturer: Mitsubishi Electric
  • Category of Device: Air Conditioner
  • Document: CMB-WP-V-GA1, File Type: PDF Data Book
  • Updated: 20-03-2024
  • Count of Pages: 192
Download CMB-WP-V-GA1 Manual (192 pages)

Read PDF Document Online:

Data: UPD 20th March 2024

Mitsubishi Electric CMB-WP-V-GA1 Air Conditioner PDF Data Book (Updated: Wednesday 20th of March 2024 12:51:26 AM)

Rating: 4.8 (rated by 10 users)

Compatible devices: MSH-24RV, MXZ-2HA40VF-E1, MSZ-WN25VA - E1, MXZ-3A30NA, CITY MULTI PEFY Series, MSZ-GF71VE, PAC-KE250TB-F, CITY MULTI PUHY-M200-300YNW-A1.

Recommended Documentation:

Text Version of Mitsubishi Electric CMB-WP-V-GA1 Air Conditioner Manual (Summary of Contents)

(Ocr-Read of Mitsubishi Electric CMB-WP-V-GA1 Document (Main Content), UPD: 20 March 2024)
  • 16, 1 - 13 PEFY MEE15K052 6. FAN CHARACTERISTICS CURVES 6. FAN CHARACTERISTICS CURVES PEFY-WP15VMS1-E External static pressure : 15Pa Power source : 220,230,240V, 50/60Hz Suction : Back inlet PEFY-WP15VMS1-E External static pressure : 5Pa Power source : 220,230,240V, 50/60Hz Suction : Back inlet PE…

  • 66, 1 - 63 1. SPECIFICATIONS HBC MEE15K052 Model name CMB-WP1016V-GA1 Number of branch 16 Power source 1-phase 220-230-240 V 50 Hz 60 Hz Power input Cooling kW 0.45/0.46/0.47 0.45/0.46/0.47 (220/230/240) Heating kW 0.45/0.46/0.47 0.45/0.46/0.47 Current input Cooling A 2.89/2.83/2.79 2.89/2.83/2.79…

  • 53, 1 - 50 PFFY 1. SPECIFICATIONS MEE15K052 I.Floor standing (Concealed type)1. S PECIFICATIONS Model PFFY-WP20VLRMM-E PFFY-WP25VLRMM-E PFFY-WP32VLRMM-E PFFY-WP40VLRMM-E Power source 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-2…

  • 45, 1 - 42 PLFY-VBM MEE15K052 5. SOUND LEVELS 5. SOUND LEVELS 5-1. Sound levels 5-2. NC curves * Measured in anechoic room. PLFY-WP-VBM-E 1.5m Measurement location PLFY-WP32VBM-E PLFY-WP40VBM-E PLFY-WP50VBM-E 27-29-30-31 27-29-30-31 27-30-32-34 Sound level dB (A) Sound level at anechoic room: Low…

  • 22, Mitsubishi Electric CMB-WP-V-GA1 1 - 19 Ceiling concealed (Middle static pressure type) PEFY-WP-VMA-E MEE15K052 I.Ceiling concealed (Middle static pressure type) 1. SPECIFICATIONS.........................................................................................................................................…

  • 175, 3. Piping Design 3 - 22 S.D. WR2 MEE15K052 1. Refrigerant and water pipe size (1) Refrigerant pipe between heat source unit and HBC controller (Part A, A1, A2, and A3) (2) Water pipe between HBC controller and indoor units (Sections a, b, c, d, e, and g) *Water Pipe size between HBC co…

DOC-2763e8dd:

Recommended:
XAVB1601, Elumina EG2522, KAC-821, FFU21C5AW2

Mr.Slim MS-CP13VA, HY-CLM09KR-001, 73XC-1SS, DWA-180C, RXYMQ4PVET
  • TECHNICAL & SERVICE MANUAL V1.4—DC-INVERTER AIR CONDITIONERSMODEL:DuctAUD-09UX4SRNL3 AUD-12UX4SSNL3 AUD-18UX4SFKL3 AUD-24UX4SFLL3 AUD-36UX4SAHH3 AUD-42UX6STHH3 AUD-48UX6SPHH3 AUD-60UX6SPHH3ADT-09UX4SRNL3 ADT-12UX4SSNL3 ADT-18UX4SFKL3 CassetteAUC-12UR4SSAA3 AUC-18UR4SFAA3 AU ...

    Model & Doc Type: ADT-12UX4SSNL3 146

  • Version Nr. 1-6 - 21.03.2022 Doc. No. 9987030082USL 1 / 18Table of Content 87030082USL1. User manual 2 .................................................................................................................................. 2. Legal regulations 2 ...................... ...

    Model & Doc Type: 87030082USL 18

  • Installation InstructionsNOTE: Read the entire instruction manual before starting the installation.Table of contentsPAGE NO. PAGE NO.SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Inverter Cover . . . . . . . . . . . . . . . . . . . . . . . . . . ...

    Model & Doc Type: Infinity 24VNA6 22

  • Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53420015-01 Printed in U.S.A. Form 42WKN-9SI Pg 1 918 8-18 Replaces: 42WKN-8SIInstallation, Operation and Maintenance InstructionsTA ...

    Model & Doc Type: AirStream 42WKN08-36 60

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Mitsubishi Electric
MU-GA50VB
40 24/11
2 Daikin
FFQ25C
25 20/12
3 Carrier
Aquasnap 30RQ
36 18/11
4 Daikin
Perfera CTXM-R
60 09/10
5 Mitsubishi
PEFY-P25 VMS1-E
108 17/03
6 Friedrich
Vert-I-Pak A-Series
29 15/03
7 DeLonghi
pacn120hp
15 07/01
8 AlpicAir
ATI-53HPDC1D
16 01/11
9 Beko
BA 110 AC
92 05/03
10 Daikin
FXSQ25MVE9
22 23/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Hitachi
50V500 - UltraVision Digital - 50" Rear Projection TV
84 1.15 Mb 12.01.2024
2 Hermstedt
StingRay 3.0
26 07.03.2024
3 Casablanca
M8510-01W
18 25.03.2024
4 Samsung
HL-T5075S - 50" Rear Projection TV
128 21.75 Mb 01.02.2024
5 Epson
AcuLaser C2000
46 1.15 Mb 24.02.2024
6 Fujitsu
Stylistic ST4000 Series
10 0.18 Mb 06.11.2023
7 Makita
HR4501C
56 24.03.2024
8 Curtis
RCD338
1 0.02 Mb 15.02.2024
9 Whirlpool
DU9100XT Series
16 1.27 Mb 07.10.2023
10 Husqvarna
J 55S L
20 09.11.2023
Operating Impressions, Questions and Answers: