Fujitsu ARU9RLF Manual, Service Instruction

Manual, Service Instruction for Fujitsu ARU9RLF Air Conditioner, Fan (69 pages)

Specifications:

1261/1261058-aru9rlf.pdf file (13 Dec 2023)
  • Manufacturer: Fujitsu
  • Category of Device: Air Conditioner, Fan
  • Document: ARU9RLF, File Type: PDF Service Instruction
  • Updated: 13-12-2023
  • Count of Pages: 69
Download ARU9RLF Manual (69 pages)

Read PDF Document Online:

Data: UPD 13th December 2023

Fujitsu ARU9RLF Air Conditioner, Fan PDF Service Instruction (Updated: Wednesday 13th of December 2023 01:20:41 AM)

Rating: 4.8 (rated by 3 users)

Compatible devices: AUYG12LVLB, AOU15RLQ, ASY18LMA-W, ARYG12LHTBP, ASTA07JEC, AWY24FBAJ, ABYG36KRTA, R410A 9370937022.

Recommended Documentation:

Text Version of Fujitsu ARU9RLF Air Conditioner, Fan Manual (Summary of Contents)

(Ocr-Read of Fujitsu ARU9RLF Document (Main Content), UPD: 13 December 2023)
  • 31, Detective Actuators: Detective details: Forecast of Cause: Check Point 3 : Replace Controller PCB Check Point 2 : Check Indoor unit electric components YESYES NO Trouble shooting 3 INDOOR UNIT Error Method: Indoor unit model information error EEPROM access abnormal Indoor unit Con…

  • 36, Indicate or Display: Refer to error code table. Trouble shooting 8 INDOOR UNIT Error Method: Drain pump error Detective Actuators: Indoor unit Controller PCB Float switch Detective details: When Float switch is ON for more than 3 minutes. Check Point 1 : Check Float switch Check operation of flo…

  • 7, 4. AUTO CHANGEOVER OPERATION 01-03 ( Fig. 3 : Operation flow chart ) START Room temp. Room temp. >Ts+4°F(2°C) ? COOLING OPERATION HEATING OPERATION YES YES NO NO NO NO YES YES TS : Setting temperature <Ts-4°F(2°C) ? Thermostat remains in OFF state for 6 minutes or longer? System st…

  • 44, Fujitsu ARU9RLF Trouble shooting 15 OUTDOOR UNIT Error Method: Detective Actuators: Detective details: Forecast of Cause : Check Point 4 : Replace Main PCB YES NO OK Current sensor error Outdoor unit Main PCB Check Point 2 : Check connections of Outdoor Unit Electrical Components Check if co…

  • 41, Trouble shooting 12 INDOOR UNIT OUTDOOR UNIT Error Method: Detective Actuators: Detective details: Forecast of Cause : Check Point 2 : Check Point 3 : 62.5100.9129.8168.6221.1292.9Resistance Value (k ) Temperature (°F) OKOK OKOK 40.0 2.03.44.66.38.7Resistance Value (k ) Temperature (°F)…

  • 16, 9. ELECTRONIC EXPANSION VALVE CONTROL The most proper opening of the electronic expansion valve is calculated and controlled under the present operating condition based on the Table 14. The compressor frequency, the detected temperature by the discharge temperature sensor, the indoor heat exch…

DOC-efcde1ad:

Recommended:
FEX831CS0, SB4100, Digital Music Changer, Audio Video Preamplifier

SEZ-KD50VAL, REVO-E, PS-101B, RAS-18 SK, R-410A, FAC122P1
  • GEPppliances.comSafety Instructions ............. 2, 3Operating InstructionsControls ...................... 4-6Care and CleaningAir Filter ........................ 6Otltdoor Coils .................... 6Installation Instructions ....... 7-10Troubleshooting Tips ........... 11Normal Operating ...

    Model & Doc Type: Appliances AKW10 48

  • 1www.enviromaster.comThe Ductless Split System of Choice!RECOGNIZE THIS SYMBOL AS AN INDICATIONOF IMPORTANT SAFETY INFORMATION.!INSTALLATION, OPERATION, AND MAINTENANCE MANUALEMI DUCTLESS SPLIT SYSTEMAIR HANDLERSFCP/FHP, WCP/WHP, CNR, and CCP/CHPP/N# 240-4373, Rev. 1.2 [04/04]FLOO ...

    Model & Doc Type: FCP/FHP 28

  • AkCondtiionerContentsAdapter Plug7Model and Serial Numbers2Air Direction4Problem Solver6Air Filter5Safety Instructions2Appliance Registration2User Maintenance Instructions 5Care and Cleaning5WarrantyBack CoverCondenser Coils5Consumer Services11Control Settings 3,4Electrical Requiremen ...

    Model & Doc Type: AVS10 12

  • M40L0001.eps M40C0001.eps M40M0002.eps 2202049172.eps Product No. FAC122P1A1 FAC122P1A2 FAC122P1A3 FAC122P1A4 Series ROOM AIR ROOM AIR ROOM AIR ROOM AIR Color white white white white Volts 115 115 115 115 BTU-Cooling 12,000BTU 12,000BTU 12,000BTU 12,000BTU Owner's Gu ...

    Model & Doc Type: FAC122P1 6

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Whirlpool
AI2209
49 01/11
2 Zelmer
23Z010
56 28/02
3 Sanyo
W MULTI SGP-EW120M2G2W
34 24/10
4 Holmes
HFH5606
2 0.57 Mb 23/09
5 Effitherm
AWT9-V5+
92 30/01
6 Chromalox
PF451-3
4 0.28 Mb 26/11
7 Ayce
LG04-11BR1
23 11/03
8 ZALMAN
CNPS6000-Al
6 0.62 Mb 13/11
9 Frigidaire
FAS184J2A5
12 04/12
10 Graco
234397
8 09/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Accuphase
AD-30
2 24.01.2024
2 IBM
22P6972
46 12.12.2023
3 Icom
IC-M1V
32 22.12.2023
4 Orion Diagnostica
QuickRead go CRP
20 19.02.2024
5 General Monitors
TA402A
51 14.12.2023
6 Novatel
ProPak
36 17.02.2024
7 LEGO
Technic 9391
32 11.02.2024
8 Edirol
P-10
2 0.99 Mb 07.03.2024
9 Jabra
MOTION
25 15.11.2023
10 ALLIANCE
ALLWH200R410
81 28.01.2024
Operating Impressions, Questions and Answers: