Lennox XPG20 Installation Instructions Manual

Installation Instructions Manual for Lennox XPG20 Heat Pump (43 pages)

Specifications:

1398/1398582-xpg20.pdf file (18 Sep 2023)
  • Manufacturer: Lennox
  • Category of Device: Heat Pump
  • Document: XPG20, File Type: PDF Installation Instructions Manual
  • Updated: 18-09-2023
  • Count of Pages: 43
Download XPG20 Manual (43 pages)

Read PDF Document Online:

Data: UPD 18th September 2023

Lennox XPG20 Heat Pump PDF Installation Instructions Manual (Updated: Monday 18th of September 2023 02:16:50 PM)

Rating: 4.6 (rated by 59 users)

Compatible devices: Magic-Pak PWC182, SPB036H4, SunSource Solar-Assisted Central Heat Pump, Elite Series HP13, Merit 10HPB Series, HP16-211V, HP40, HPXA16-024.

Recommended Documentation:

Text Version of Lennox XPG20 Heat Pump Manual (Summary of Contents)

(Ocr-Read of Lennox XPG20 Document (Main Content), UPD: 18 September 2023)
  • 37, Lennox XPG20 Page 37 XPG20 SERIES SLEEVE AMBIENT SENSOR − EXTEND TIP OF PLASTIC SENSOR JUST OUTSIDE OF PLASTIC SLEEVE. WIRE TIE DEFROST COIL SENSOR: 12 TUBES UP FROM BOTTOM (11−1/2") OUTSIDE ROW DISCHARGE LINE SENSOR DETAIL A DETAIL B Place ambient sensor and wire from DCB inside of plastic sleeve an…

  • 28, Page 28 506238−01 06/09 Table 3. HFC−410A Normal Operating Pressures 1 This table is used to perform maintenance checks and is not a procedure for charging the system. Minor varia- tions in these pressures may be due to differences in installations. Significant deviations could mean tha…

  • 29, Page 29 XPG20 SERIES Table 5. HFC−410A Temp. (°F) − Pressure (Psig) °F Psig °F Psig °F Psig °F Psig 32 100.8 63 178.5 94 290.8 125 445.9 33 102.9 64 181.6 95 295.1 126 451.8 34 105.0 65 184.3 96 299.4 127 457.6 35 107.1 66 187.7 97 303.8 128 463.5 36 109.2 67 190.9 98 308.2 129…

  • 30, Page 30 506238−01 06/09 S Disconnecting R wire from the LSOM’s R terminal. S Turning the indoor unit off an on again 2. Automatic Reset After an alert is detected, the LSOM continues to monitor the compressor and system. When/if conditions return to normal, the alert code is turned…

  • 8, Page 8 506238−01 06/09 ELEVATING THE UNIT These units are outfitted with elongated support feet as illustrated in Figure 7. LEG DETAIL BASE 2" (50.8MM) SCH 40 FEMALE THREADED ADAPTER Figure 7. Elevated Slab Mounting using Feet Extenders If additional elevation is necessary, raise the unit by…

  • 27, Page 27 XPG20 SERIES 1. Check the airflow as illustrated in Figure 20 to be sure the indoor airflow is as required. (Make any air flow adjustments before continuing with the following procedure.) 2. Measure outdoor ambient temperature; determine whether to use cooling mode or heating …

DOC-bb30832d:

Recommended:
Spitfire180, 15-1837, SDW5005GN, EW-7303HPn V2

SL280UHNV Series, 2U18MS2VHB, 38YCA, SideWinder SWD008, YT024
  • Heating and Air ConditioningAFFINITY & AFFINITY ADVANCEDGEOTHERMAL HEAT PUMPSSINGLE AND DUAL CAPACITYMODELS:YAFS012 - 018(1 THRU 1.5 NOMINAL TONS)YAFT026 - 072(2 THRU 6 NOMINAL TONS)Due to continuous product improvement, specifications are subject to change without notice. Visit us o ...

    Model & Doc Type: YAFS018 68

  • 1 68-0076—1CONTENTSSpecifications ................................................. 2Ordering Information ..................................... 2Selection/Application ..................................... 5Installation ................................................... 12Checkout.............. ...

    Model & Doc Type: CHRONOTHERM III T8611M 32

  • Copyright 2003 Carrier Corporation Form 38YCG-4PD ProductData 38YCG (60 Hz)Heat Pump Sizes 018 thru 060 The 38YCG Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With SEER ratings up to 11.5 and HSPF from 6.8 to ...

    Model & Doc Type: 38YCG 28

  • Installation & Operations ManualYT MODELS PACKAGED WATER-TO-AIR MULTI-POSITIONAL HEAT PUMPSREVISION:B20D218-01NN20D218-01NNScan or Click Here for YouTube InstallationVideoFlex ConnectorFlex ConnectorSupply AirReturn and Supply Air Duct SystemMaintain supply ange duct size for 12” ...

    Model & Doc Type: YT024 78

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Lennox
14HPX?018
24 01/01
2 Oilon
RE 35
72 30/10
3 Rheem
RTHP009
16 19/11
4 Viessmann
VITOCAL 300-G
60 09/02
5 Ecoer
EODA18H-2436
35 29/02
6 Lennox
CLIMATIC 40
32 06/01
7 Trane
RAUS 160-400
39 17/12
8 VOKERA
AriaPRO 004 M
36 13/12
9 Bard
SH612
23 16/10
10 Carrier
38QW
20 3.28 Mb 12/02

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Foppapedretti
TreSystem
130 24.11.2023
2 Samsung
HT-C330
39 2.3 Mb 13.11.2023
3 SEVERIN
WK 3645
4 02.12.2023
4 Russell Hobbs
RHC 12
8 07.04.2024
5 Epson
C2600/2600
473 9.74 Mb 10.10.2023
6 Rinnai
RB-713N(S)
4 02.12.2023
7 EWM
Saturn 301 KGE M1.02
60 26.03.2024
8 Vacmaster
VMVK1520SIWC
12 30.01.2024
9 BH FITNESS
SK9900RTV
35 4.44 Mb 12.12.2023
10 Sony
SA-W90
17 24.12.2023
Operating Impressions, Questions and Answers: