Specifications:45/45212-805016_3a_805022_3a_805025_10a_instructions.pdf file (19 Mar 2024)
|
Audio Authority 805-016 (3A), 805-022 (3A), 805-025 (10A) Power Supply PDF Installation (Updated: Tuesday 19th of March 2024 01:10:29 PM)
Rating: 4.6 (rated by 78 users)
Compatible devices: RK1, INFINITE 20A, AX 501, NH Plus series, PSI 880-40R, TT-6080A, EX Series, PRM150.
Recommended Documentation:
752-240 2/02 2048 Mercer Road, Lexington, Kentucky 40511-1071 Phone: 859/233-4599 • Fax: 859/233-4510 Customer Toll-Free USA & Canada: 800/322-8346 Website: http://www.audioauthority.com Power Supply Instructions Models 805-016 (3A) 805-022 (3A) and 805-025 (10A) Installation These power supplies are filtered and regulated at 13.8 volts DC. They are particularly suited for audio/video applications in indoor environments. The Wall Mounting Bracket If mounting on a wall or other vertical surface is desired, remove the two rubber feet closest to the output terminals and use the screws to install the mounting bracket in the holes where the feet were attached. Use the two larger screws provided to hang the power supply on a vertical surface such as wood or metal. Metal anchors will be required if the supply is to be mounted on a drywall surface. Grounding Equipment powered by this supply receives an earth ground through the wire connecting the black negative output terminal and the chassis, which is earth grounded through its power cord. 752-240 2/02 2048 Mercer Road, Lexington, Kentucky 40511-1071 Phone: 859/233-4599 • Fax: 859/233-4510 Customer Toll-Free USA & Canada: 800/322-8346 Website: http://www.audioauthority.com Power Supply Instructions Models 805-016 (3A) 805-022 (3A) and 805-025 (10A) Installation These power supplies are filtered and regulated at 13.8 volts DC. They are particularly suited for audio/video applications in indoor environments. The Wall Mounting Bracket If mounting on a wall or other vertical surface is desired, remove the two rubber feet closest to the output terminals and use the screws to install the mounting bracket in the holes where the feet were attached. Use the two larger screws provided to hang the power supply on a vertical surface such as wood or metal. Metal anchors will be required if the supply is to be mounted on a drywall surface. Grounding Equipment powered by this supply receives an earth ground through the wire connecting the black negative output terminal and the chassis, which is earth grounded through its power cord.
Hobart Guide: UW50 (#AY19S7)
UW50, 8, hobart/uw50.pdf
Reference Book (AW988, #C2Z6CE)
AW988, 2, alienware/aw988.pdf
#HD18XQ: ALICANTE Alicante CD31 Handbook
ALICANTE Alicante CD31, 26, blaupunkt/alicante-alicante-cd31.pdf
Instruction (Storage Manager, #W2XSI4)
Storage Manager, 188, adaptec/storage-manager.pdf
VTech Cordless Telephone Manual (#2X5A45)
CareLine SN1196, 162, vtech/careline-sn1196.pdf
Philips Instruction Stereo System FW 750C (#K8IQUJ)
FW 750C, 24, philips/fw-750c.pdf
Craftsman Lawn Mower Manual (#5766OK)
917.376678, 48, craftsman/917-376678.pdf
Clock Radio Guidance #5563J7
ICP211, 7, ilive/icp211.pdf
Sanyo TV Manual (#81CS5P)
DS27820, 68, sanyo/ds27820.pdf
GE Guide Oven JKS06 (#244577)
JKS06, 3, ge/jks06.pdf
3 Temperature Measurement PointLGA-175 GroundLGA-192 Series Operation and Parallel OperationLGA-161 FunctionLGA-161.1 Input voltage range LGA-161.2 Inrush current limiting LGA-161.3 Overcurrent protection LGA-161.4 Overvoltage protection LGA-161.5 Output voltage adjustment range ...
Model & Doc Type: LGA100A 7
SmartPro 230V 1kVA 500W Line-Interactive UPS,Tower, LCD, USB, 6 OutletsMODEL NUMBER: SMX1000LCDProtects connected mission-critical equipment against damage, downtime and data loss due to blackouts,brownouts, power surges and line noise. Ideal for home/office workstations, media centers and homeenter ...
Model & Doc Type: SMX1000LCD 5
Power supply 24 V AC RMD Order-No. : 7591 00 01 Operation- andAssembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and othe ...
Model & Doc Type: 7591 00 01 3
Data Power Solutions Quick Start Guide Data Power Solutions Quick Start Guide Issue: 10640205 Issue Date: February 2009 This guide is intended to be used in conjunction with the full Install and Operation manual IPN 997-00012-41, available from the documentation pages o ...
Model & Doc Type: 10640205 29
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Icom | PS-125 |
2 | 25/02 | ||
2 | Siemens | SINUMERIK 840D sl |
829 | 11/11 | ||
3 | Riden | RD6006 |
25 | 04/11 | ||
4 | Tripp Lite | PRO550X |
7 | 0.21 Mb | 06/12 | |
5 | Vertiv | NetSure 801 CAA Series |
158 | 06/02 | ||
6 | Eaton | Crouse-hinds series |
16 | 30/01 | ||
7 | Hameg | HM 7042-4 |
28 | 08/02 | ||
8 | Panasonic | AC Geared-Motor M9RZ90GB4LG |
3 | 0.1 Mb | 08/02 | |
9 | Anton/Bauer | INTERACTIVE 2400 Series |
10 | 19/02 | ||
10 | Rolls | RPB486 |
2 | 0.11 Mb | 08/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | GST | DC-M9101 |
2 | 07.01.2024 | ||
2 | Sony | MHC-BX2 |
44 | 0.56 Mb | 05.03.2024 | |
3 | Craftsman | 247.88780 |
56 | 15.02 Mb | 14.01.2024 | |
4 | NAiS | KT7 |
26 | 02.03.2024 | ||
5 | Levenhuk | 40L |
44 | 07.03.2024 | ||
6 | Dynex | PM01433-A - DX-NRUTER Wireless N Router |
71 | 8.88 Mb | 27.12.2023 | |
7 | Gree | GWH12UC-D3DNA4A |
114 | 11.12.2023 | ||
8 | mabe | FMM515HPWWY0 |
40 | 15.02.2024 | ||
9 | Nortel | CallPilot 150 |
90 | 14.10.2023 | ||
10 | Mazda | speed 6 2007 |
384 | 14.12.2023 |