Bacharach HGM300 Installation Manual

Installation Manual for Bacharach HGM300 Adapter, Carbon Monoxide Alarm (10 pages)

Specifications:

54/54764-hgm300.pdf file (24 Feb 2024)
  • Manufacturer: Bacharach
  • Category of Device: Adapter, Carbon Monoxide Alarm
  • Document: HGM300, File Type: PDF Installation Manual
  • Updated: 24-02-2024
  • Count of Pages: 10
Download HGM300 Manual (10 pages)

Read PDF Document Online:

Data: UPD 24th February 2024

Bacharach HGM300 Adapter, Carbon Monoxide Alarm PDF Installation Manual (Updated: Saturday 24th of February 2024 11:02:18 AM)

Rating: 4.2 (rated by 78 users)

Compatible devices: Fyrite Tech 50, Monoxor III, Draftrite, MGD-100, Multi-Zone 3015-6143, 300, 2825, IEQ Chek.

Recommended Documentation:

Text Version of Bacharach HGM300 Adapter, Carbon Monoxide Alarm Manual (Summary of Contents)

(Ocr-Read of Bacharach HGM300 Document (Main Content), UPD: 24 February 2024)
  • 3, Bacharach HGM300 If an RDM800 remote display is NOT used with the adapter, refer to Figure 2 for wiring details. In this case, all wiring between the HGM300 main board and adapter is contained within the HGM300 and the only external cable is the N2 communications cable. …

  • 2, The adapter board mounts on the rear of the HGM300 door. Position the adapter board so as not to interfere with the HGM internal components when the door is shut. Mark (Figure 1) and drill the board’s four corner holes and center hole in the door. Install the five standoffs on the re…

  • 1, 3015-4570 Revision 1.1 8/6/03 Installation Guide Bacharach HGM300 to Johnson Metasys N2 Communications Adapter Electrically Isolated N2 Port Version Introduction The Bacharach HGM300 to Johnson Metasys N2 Communcations Adapter enables an HGM300 Refrigerant Monitor to communica…

  • 7, Setting Metasys N2 Address On Communication Adapter Switches 1-8 on the adapter’s ‘B’ dipswitch are used to set the Metasys N2 node address. Possible addresses are 1-255. Use the following technique to set switches B1-B8: Divide the desired N2 address by 16. Take the integer pa…

  • 9, There are several ADI points which can provide useful information such as type of refrigerant programmed for each zone, number of zones actually installed in the HGM, the number of zones in alarm, HGM operating mode, etc. Alarm Acknowledge Options Two alarm acknowledge options are s…

  • 4, If an RDM800 remote display IS to be used with the adapter, refer to Figure 3 for wiring details. Note that when the RDM800 is used, TWO RS-485 cables must be run between the HGM300 and RDM800, so plan accordingly. In either case, be sure to set the HGM300’s internal “Terminat…

DOC-ed6708d:

Recommended:
42PFL9703D, ES-D3A, AT-VGA0505, EL460

DX-37L200A12, EXPLORER 500, BL10e - HP ProLiant - 512 MB RAM, HGM300, PLE300, 70032
  • VSP-V-9939AIssue 81 947939AV-9939AMICROPHONE ADAPTORINTRODUCTIONThese instructions provide identification, installation,connection, operation, and maintenance informationfor the V-9939A, Microphone Adaptor.The V-9939A is a Microphone Adaptor designed tobe used with Valcom paging equi ...

    Model & Doc Type: V-9939A 8

  • BL8x0c i2 Server Installation Read-Me-First Document Before installing the Windows operating system (OS) on any HP Integrity BL860c i2, BL870c i2, or BL890c i2 server blade, you must perform the following steps, in order: 1. Ensure that you are installing the OS to one of the following co ...

    Model & Doc Type: Integrity BL890c i2 2

  • 1RIGHT-ANGLE POLAR ALIGNMENT SCOPE (RAPAS) INSTRUCTIONSCongratulations on your receipt of our new polar alignment scope and your new-found freedom from neck strain. The Astro-Physics Right-Angle Polar Scope has been machined to a very high level of accuracy. The optics and reticle are also very ...

    Model & Doc Type: RAPAS 6

  • SAS END-USER GUIDEMoving to Serial TechnologiesParallel SCSI technology has been the widely deployed standard in server and storagedata centers for the last 20 years. While parallel SCSI has been a reliable standardinterface, the technology has reached its highest performance level with the ...

    Model & Doc Type: Serial Attached SCSI 11

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Velleman
HQ Power HQM111C
3 08/04
2 Schwaiger
AV500
17 19/03
3 Enabling Devices
561
2 07/04
4 HP
438031-B21 - 1:10Gb Ethernet BL-c Switch
65 1.13 Mb 17/04
5 Abocom
WU5202
2 1.39 Mb 29/11
6 Compex
iWavePort Series
32 17/12
7 WAGO
I/O-SYSTEM 750
236 14/02
8 SeaLevel
SeaLINK
15 05/03
9 Abocom
WUG2650
2 0.2 Mb 16/01
10 Sonel
AutoISO-5000
4 31/03

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Sony
CDX-SW330 - Fm/am Compact Disc Player
32 0.61 Mb 10.02.2024
2 Roland
CG-8
2 0.33 Mb 07.03.2024
3 Chroma
Color Force 72
2 11.12.2023
4 Comnet
CWGE2SCS2
4 09.01.2024
5 RocketFish
RF-GWII015
2 0.22 Mb 16.11.2023
6 Samsung
LN40B500P3FXZA
57 24.01.2024
7 Sony
KP-44PX2
146 12.4 Mb 20.10.2023
8 Craftsman
315.11751
11 12.10.2023
9 Chicago Electric
96435
15 30.12.2023
10 Brother
PT-11Q
2 0.33 Mb 13.01.2024
Operating Impressions, Questions and Answers: