UNI-T UT12B Manual, Overview

Manual, Overview for UNI-T UT12B Test Equipment (1 pages)

Specifications:

158/158469-ut12b.pdf file (30 Jan 2024)
  • Manufacturer: UNI-T
  • Category of Device: Test Equipment
  • Document: UT12B, File Type: PDF Overview
  • Updated: 30-01-2024
  • Count of Pages: 1
Download UT12B Manual (1 pages)

Read PDF Document Online:

Data: UPD 30th January 2024

UNI-T UT12B Test Equipment PDF Overview (Updated: Tuesday 30th of January 2024 10:52:04 AM)

Rating: 4.8 (rated by 35 users)

Compatible devices: UT522, utd2000, UT3500 Series, UT677A, UPO2000E Series, UT516B, UT501B, UT890D.

Recommended Documentation:

Text Version of UNI-T UT12B Test Equipment Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 30 January 2024)


UT12B
Voltage Detector
Double Insulated
Warning. Refer to the Operating Manual
Danger of electric shock
Conforms to Standards of European Union
This Operating Manual covers information on safety
and cautions. Read and understand all of the
instructions and safety information in this manual
before operating or servicing this tool.  Failure to
understand how to safely operate this tool could
result in an accident causing serious injury or death.
 Figure 1
 Figure 2
Overview
UT12B is intended to check for the presence of
AC voltage, signaling the user with a beep and a
flashing LED.
Do not use the unit if it is wet, damaged or
cannot operate correctly.
Do not apply more than the rated voltage
between the probe tip and earth ground.
When the unit working at voltage over 30V in
AC, special care should be taken for there is
danger of electric shock.
Follow the local countries safety requirements
and standards.
Warning
This unit is only designed for the specialist
who has certain technical knowledge to use.
This unit is intended to check for the presence
of AC voltage, the voltage range is 90~1000V.
 Make sure the tested inductor possible
voltage range before carrying out checking.
When you cannot sure the tested inductor
voltage range, the unit does not have any
response.  It does not mean the tested inductor
does not have dangerous voltage, do not use
any part of the body to touch the tested
inductor.
When carrying out checking, keep your fingers
behind the probe tip finger guards.
Pollution Degree 2
Battery: 2 x 1.5V AAA
Operation
1)
2)
3)
4)
5)
Battery Indication
The LED will not flash when you turn the unit on or
during checking if the battery is less than 2V.  The
beep sounds will still have but may be weaker.
Safety Information
This unit complies with the standards
EN61010-1, UL61010-1 and CASC 22.1
No. 61010-1 safety measurement requirement:
in pollution degree 2, overvoltage category
(CAT. IV 1000V)
Maintenance
1)   Disconnect the unit from the circuit.
2)   One hand holds the unit.  Place another hand’s
      thumb on the probe cap as the figure below
3)   Pull back the back housing as the figure below
4)   Replace the batteries (observe polarity).
      2 x1.5V AAA
5)   Push back the back housing.
Periodically wipe the case with a damp cloth and
mild detergent; do not use abrasives or solvents.
International Electrical Symbols
Symbols used on the Meter and in this manual are
explained below:
CAT.IV: Primary supply level, overhead lines, cable
systems etc.  Some examples include cables,
meters, transformers, and other exterior equipment
owned by the power utility.
Use the unit only as specified in this operating
manual, otherwise the protection provided by the
unit may be impaired.
Specifications
Indicators: LED and Beep
Voltage range: 90VAC ~ 1000VAC
Measurement Category IV 1000V per IEC61010
Temperature:
Ø Operating: -10~50
Ø Storage: 10~50
Humidity:  95%
Altitude: 2000m
Turn the unit on by pressing the power button
once, the unit beeps and LED flashes two times.
 When the unit is under standby mode, the LED
keeps flashing two times in every 1.5 seconds.
Place the probe tip on or near the circuit or unit
to be tested.  Beep and flashing LED indicate
the presence of voltage (90VAC to 1000VAC).
To turn off the beeper, you could press the
power button once after turning on the unit,
then you will hear a beep sound indicating the
beeper is off.  After the beeper is off, only LED
will flash during checking.   This way could save
battery.
Press power button to toggle between beeper
mode and silent mode. Beep two times enters
beeper mode, while beep one time enters silent
mode.
In order to save battery, the unit will auto power
off when it is not used for around 3 minutes.
The beeper sounds 2 times continuously and
then one long beep means the unit is power
off.
Press and hold the power button for two
seconds to turn the unit off, there will be one
second long beep.
Copyright 2007 Uni-Trend Group Limited.
All rights reserved.
Manufacturer:
Uni-Trend Technology (Dongguan) Limited
Dong Fang Da Dao
Bei Shan Dong Fang Industrial Development District
Hu Men Town, Dongguan City
Guang Dong Province
China
Postal Code: 523 925
Headquarters:
Uni-Trend Group Limited
Rm901, 9/F, Nanyang Plaza
57 Hung To Road
Kwun Tong
Kowloon, Hong Kong
Tel: (852) 2950 9168
Fax: (852) 2950 9303
Email: [email protected]
http://www.uni-trend.com
This operating manual is subject to change
without notice.
*END*





DOC-22b5d439:

Recommended:
NS20A, PRIME H310M-E, Discovery mini DUAL PANORAMA PLUS DATE, SRCD

PT-5, SVTS272, SKW 400, 211083, FT-30
  • OBDSTAR User ManualUser ManualStatementThis handbook is the manual of BMT-08. Without the writtenpermission from the manufacturer, any company or individual shallnot copy or backup it in any form (electronic, mechanical,photocopying, recording or otherwise).This manual is onlyoperating i ...

    Model & Doc Type: BMT-08 16

  • The TTC Digital Torque Tool Tester is a simple operation test in-strument for quickly checking torque tool performance up to 590 ft-lb (800 N-m). The TTC Series provides exceptional accuracy for measuring torque on various products including torque wrench-es, manual screwdrivers, elec ...

    Model & Doc Type: TTC Series 10

  • 2 ISSUED: January2002 LTXXX-OM-E RevBF IRST T HINGS...FirstIn this preface, see howTomake sure you have everythingTo operate withsafetyTo get to know your Waverunner scopeToinstall and powerupTo initializeTo check the system statusTo install newsoftware and firmwareTo activate the screen save ...

    Model & Doc Type: LeCroy Waverunner LT Series 13

  • 85021 A/B/C DIRECTIONAL BRIDGE SERIAI, NUMBERS This manual applies directly to the HP Model 85021A/B/G Directional Bridge with serial numbers prefixed as follows: Model Serial Ptefix 85021A 2312A 850218 2309A 85021C 2314A With changes described in Section VII, this manu ...

    Model & Doc Type: 85021 A 67

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Rigol
MSO7000 Series
374 14/02
2 Herth+Buss
AirGuard
88 24/12
3 Westfalia
20 57 57
22 12/11
4 Sun Microsystems
SUN-FIN-N
8 27/01
5 Cristini
FiberScanONE
74 01/01
6 ZORN INSTRUMENTS
ZFG 3.0
3 05/12
7 KNOVA
KN 8065-E
4 15/01
8 audioscan
RM500SL
126 29/03
9 YOKOGAWA
ScopeCorder DL350
258 15/02
10 EXFO
MaxTester series
175 14/12

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 HP
Vectra VE5 4
10 03.12.2023
2 Optoma
HD66
2 06.02.2024
3 Hotpoint
RFR51V
16 0.33 Mb 27.03.2024
4 ZyXEL Communications
ES-3148
362 14.4 Mb 20.11.2023
5 Astronomy Technologies
Astro-Tech AT6RC
2 22.01.2024
6 Comfee
CGT 60 EAA
64 19.01.2024
7 for_q
FQ-AHE 4020 BASIC
20 03.03.2024
8 Parkside
PWS 230 A1 ANGLE GRINDER
46 26.12.2023
9 Conair
VS Sassoon PRO VSCS56BA
2 12.10.2023
10 Liberator
Rugged 7
2 06.04.2024
Operating Impressions, Questions and Answers: