Elenco Electronics M-1740 Manual, Operating Instructions

Manual, Operating Instructions for Elenco Electronics M-1740 Multimeter (1 pages)

Specifications:

204/204689-m1740.pdf file (21 Oct 2023)
  • Manufacturer: Elenco Electronics
  • Category of Device: Multimeter
  • Document: M-1740, File Type: PDF Operating Instructions
  • Updated: 21-10-2023
  • Count of Pages: 1
Download M-1740 Manual (1 pages)

Read PDF Document Online:

Data: UPD 21st October 2023

Elenco Electronics M-1740 Multimeter PDF Operating Instructions (Updated: Saturday 21st of October 2023 07:16:48 PM)

Rating: 4.9 (rated by 21 users)

Compatible devices: M-2795, M-1005K, M-3900, M-1750, M-1008K, M-2625, M-1700, M-1150K.

Recommended Documentation:

Text Version of Elenco Electronics M-1740 Multimeter Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 21 October 2023)


OPERATING INSTRUCTIONS
ELENCO M-1740
DIGITAL MULTIMETER
OPERATION
Before taking any measurements, read the Safety Information
Section.  Always examine the instrument for damage,
contamination (excessive dirt, grease, etc.) and defects.
Examine the test leads for cracked or frayed insulation.  If any
abnormal conditions exist, do not attempt to make any
measurements.
Voltage Measurements
1. Connect the red test lead to the “VΩA” jack and the black
test lead to the “COM” jack.
2. Set the Function/Range switch to the desired current range
and slide the “AC/DC” selector switch to the desired
voltage type.  If magnitude of voltage is not known, set
switch to the highest range and reduce until a satisfactory
reading is obtained.
3. Connect the test leads to the device or circuit being
measured.
4. For DC, a (-) sign is displayed for negative polarity;
positive polarity is implied.
Current Measurements
1. Set the Function/Range switch to the desired current range
and slide the “AC/DC” selector switch to the desired
current type.
2. For current measurements less than 200mA, connect the
red test lead to the “VΩA” jack and the black test lead to
the COM jack.
3. For current measurements over 200mA or greater, connect
the red test lead to the 10A jack and the black test lead to
the COM jack.
SAFETY INFORMATION
The following safety information must be observed to insure
maximum personal safety during the operation of this meter:
1. Do not use the meter if the meter or test leads look
damaged, or if you suspect that the meter is not operating
properly.
2. This meter is not recommended for high voltage industrial
use; for example, not for measurements of 440VAC or
600VAC industrial power mains.  The unit is intended for
use with low energy circuits to 600V AC/DC or high
energy circuits to 250VAC or DC.  Accidental misuse by
connection across a high voltage, high energy power
source when the meter is set up for mA measurement may
be very hazardous.
3. Turn off power to the circuit under test before cutting,
unsoldering, or breaking the circuit.  Small amounts of
current can be dangerous.
4. Use caution when working above 60VDC or 30VAC rms.
Such voltages pose a shock hazard.
5. When using the probes, keep your fingers behind the
finger guards on the probes.
6. Measuring voltage which exceeds the limits of the
multimeter may damage the meter and expose the operator
to a shock hazard.  Always recognize the meter voltage
limits as stated on the front of the meter.
7. If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment
may be impaired.
4. Remove power from the circuit under test and open the
normal circuit path where the measurement is to be taken.
Connect the meter in series with the circuit.
5. Do not continually measure 10A as the shunt wire will
heat up.  Allow 60 seconds max.  At 5A or less, continuous
use is OK.
Resistance and Continuity Measurements
1. Set the Function/Range switch to the desired resistance
range or continuity position.
2. Remove power from the equipment under test.
3. Connect the red test lead to the “VΩA” jack and the black
test lead to the “COM” jack.
4. Touch the probes to the test points.  In ohms, the value
indicated in the display is the measured value of resistance.
In continuity test, the beeper sounds continuously, if the
resistance is less than 40Ω +/-20Ω.
WARNING
The accuracy of the functions might be slightly affected
when exposed to a radiated electromagnetic field
environment, e.g. radio, telephone or similar.
Diode Tests
1. Connect the red test lead to the “VΩA” jack and the black
test lead to the “COM” jack.
2. Set the Function/Range switch to the “       ” position.
3. Turn off power to the circuit under test.
4. Touch probes to the diode.  A forward-voltage drop is
about 0.6V (typical for a silicon diode).
5. Reverse probes.  If the diode is good, “OL” is displayed.
If the diode is shorted, “.000” or another number is
displayed.
SPECIFICATIONS
Display: 3 1/2 digit liquid crystal display (LCD) with a
maximum reading of 1999.
Polarity: Automatic, positive implied, negative polarity
indication.
Overrange: (OL) or (-OL) is displayed.
Zero: Automatic.
Low Battery Indication: The “       ” is displayed when the
battery voltage drops below the operating level.
Measurement Rate: 2.5 times per second, nominal.
Operating Environment: 0
O
C to 40
O
C at <70% relative
humidity.
Storage Temperature: -20
O
C to 60
O
C, 0 to 80% R.H. with
battery removed from meter.
Accuracy: Stated accuracy at 23
O
C +/-5
O
C, <75% relative
humidity.
Safety: According to EN61010-1 protection class II over-
voltage category (CAT II 600V) pollution degree 2.
Power: Single standard 9-volt battery, NEDA 1604, JIS
006P, IEC 6F22.
Battery Life: 150 hours typical with carbon-zinc.
Dimensions: 151mm (H) x 70mm (W) x 38mm (D).
Weight: Approx. 7 oz. (200g.) including battery.
Accessories: One pair test leads, one spare fuse, 9V battery
(installed) and operating instructions.
6. If the diode is open, “OL” is displayed in both directions.
7. If the junction is measured in a circuit and a low reading is
obtained with both lead connections, the junction may be
shunted by a resistance of less than 1kΩ.  In this case, the
diode must be disconnected from the circuit for accurate
testing.
Transistor Gain Measurements
1. Set the Function/Range switch to the desired h
FE range
(PNP or NPN type transistor).
2. Never apply an external voltage to the hFE socket.  Damage
to the meter may result.
3. Plug the transistor directly into the hFE socket.  The sockets
are labeled E, B, and C for emitter, base and collector.
4. Read the transistor hFE (DC gain) directly from the display.
Frequency Measurements
1. Set the Function/Range switch to the Hz position.
2. Connect the red test lead to the “VΩA” jack and the black
test lead to the “COM” jack.
3. Connect the test leads to the point of measurement and
read the frequency from the display.
Capacitance Measurements
1. Set the Function/Range switch to the desired F
(capacitance) range.
2. Never apply an external voltage to the Cx sockets.
Damage to the meter may result.
3. Insert the capacitor leads directly into the Cx socket.
4. Read the capacitance directly from the display.
+
MAINTENANCE
Battery Replacement
Power is supplied by a 9 volt “transistor” battery (NEDA
1604, IEC 6F22).  The “      ” appears on the LCD display
when replacement is needed.  To replace the battery, remove
the two screws from the back of the meter and lift off the front
case.  Remove the battery from battery contacts.
Fuse Replacement
If no current measurements are possible, check for a blown
overload protection fuse.  There are two fuses; F1 for the
“VΩA” jack and F2 for the 10A jack.  For access to fuses,
remove the two screws from the back of the meter and lift off
the front case.  Replace F1 only with the original type
0.8A/250V, fast acting fuse.  Replace F2 only with the
original type 10A/600V, fast acting ceramic fuse.
Cleaning
Periodically wipe the case with a damp cloth and detergent,
do not use abrasives or solvents.
753054
WARNING
Remove test leads before changing battery or
performing any servicing.
+
DC Accuracy AC Accuracy Input Impedance Maximum Input
Voltage +/-(1.9%rdg+4dgts) 500VDC or ACrms
(AC 50Hz - 500Hz) +/-(0.5%rdg+1dgt) on 600V range 10MΩ on 200mV range
+/-(1.0%rdg+4dgts) 600VDC or ACrms
on all other ranges on all other ranges
Current A DC Accuracy AC Accuracy Voltage Burden Input Protection
mA +/-(1.0%rdg+1dgt) +/-(2.0%rdg+4dgts) 0.7V 0.5A/250V fuse
10A +/-(3.0%rdg+1dgt) +/-(3.5%rdg+4dgts) 1.2V 10A/600V fuse
Range Accuracy Test Condition Input Protection
200Ω +/-(0.8%rdg+3dgts) 3.0VDC
Ohm 2kΩ - 2,000kΩ +/-(0.8%rdg+1dgt) 0.3VDC
20MΩ +/-(3.0%rdg+3dgts) 0.3VDC 500VDC or ACrms
Diode 2V +/-(3.0%rdg+3dgts) 1mA +/-0.6mA
Continuity 200Ω
<40Ω +/-20Ω Beeper <40Ω
3.0VDC
Capacitance 2,000pF - 20µF +/-(2.0%rdg+10dgts) 2.5Hz 3V
h
FE 0-1,000 N/A lb = 10µA approx. Vce<3.5V
Frequency 2kHz - 15MHz +/-(0.1%rdg+1dgt) Sensitivity 500VDC or ACrms
(auto-range) (10Hz - 15MHz) 1.5Vrms





DOC-cf15fc2e:

Recommended:
TS-5, EXERCISE CYCLE RBEX49840, FR-3, 1633167

HI 98171, 4339B, 03022, 513121, HI 38076
  • ® 71X Series Process Calibrators Calibration Manual PN 686540 January 1998 Rev. 11, 3/12 © 1998-2012 Fluke Corporation, All rights reserved. Printed in U.S.A. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 1. ...

    Model & Doc Type: 71X Series 98

  • Instruction Manual HI 38076Zinc Test Kitwith Checker Discwww.hannainst.comDear Customer,Thank you for choosing a Hanna Product.Please read the instruction sheet carefully before using thetest kit. It will provide you with the necessary informationfor correct use of the kit. If you need ad ...

    Model & Doc Type: HI 38076 2

  • G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638, 27754546Tel. : (022) 24124540, 24181649, 27750662, 27750292Email : [email protected] Website : www.kusamelectrical.com ®LIST OF PRODUCTS¬ Digital Multimeter ¬ D ...

    Model & Doc Type: KM 60-T 14

  • METRAHIT⏐X-TRA⏐TECH⏐PRO⏐BASEMETRAHIT⏐OUTDOORTRMS Digital multimeterKortfattad bruksanvisningShort-form Operating Instructions3-349-351-525/5.08Tryckt i Tyskaldn • Rätt till ändringar förbehålles • En pdf-version finns tillgänglig på InternetEdited in Germany • Sub ...

    Model & Doc Type: METRAHIT X-tra 2

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Agilent Technologies
4294A
469 13.45 Mb 29/02
2 Craftsman
82141
36 0.93 Mb 14/03
3 Omega
FMG600 Series
48 17/02
4 Albercorp
Cellcorder
47 17/03
5 Agilent Technologies
4339B
18 0.11 Mb 20/01
6 RS
IDM67
28 18/03
7 Fluke
8506A
316 23/02
8 Fluke
718Ex 30G
36 0.77 Mb 03/02
9 Fluke
741B
1 0.56 Mb 10/12
10 Extech Instruments
EX542
17 06/02

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Mitsubishi Electric
MUCFH-GA35VB
48 19.03.2024
2 Kenmore
63016302400
32 02.11.2023
3 DANE-ELEC
SO SPEAKY BLACK DIAMOND
2 0.4 Mb 05.12.2023
4 Samsung
UA55HU9000
25 17.03.2024
5 Visonic
SRN-2000
4 29.02.2024
6 Roland
CUBE-40
8 0.18 Mb 22.03.2024
7 Casio
QW-900
6 3.11 Mb 20.01.2024
8 Avanti
DG2452B
51 1.67 Mb 04.03.2024
9 Alfresco
AGBQ-42
2 0.15 Mb 04.11.2023
10 Plantronics
MCD100
2 06.11.2023
Operating Impressions, Questions and Answers: