Fire-Lite MS-9200UDLS/E Manual, Operating Instructions

Manual, Operating Instructions for Fire-Lite MS-9200UDLS/E Control Panel, Fire Alarms (1 pages)

Specifications:

251/251563-ms9200udlse_operating_instructions.pdf file (13 Feb 2024)
  • Manufacturer: Fire-Lite
  • Category of Device: Control Panel, Fire Alarms
  • Document: MS-9200UDLS/E, File Type: PDF Operating Instructions
  • Updated: 13-02-2024
  • Count of Pages: 1
Download MS-9200UDLS/E Manual (1 pages)

Read PDF Document Online:

Data: UPD 13th February 2024

Fire-Lite MS-9200UDLS/E Control Panel, Fire Alarms PDF Operating Instructions (Updated: Tuesday 13th of February 2024 01:15:49 PM)

Rating: 4.7 (rated by 59 users)

Compatible devices: MS-9200C, MDF-300, CHS-6 Chassis, B310LP, MS-9600, LDM-32F, MS-9050UD series, BG-12LR.

Recommended Documentation:

Text Version of Fire-Lite MS-9200UDLS/E Control Panel, Fire Alarms Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 13 February 2024)


WHEN AUDIBLE DEVICES ARE SOUNDING -
FOR AN ALARM
1. Evacuate the protected area
2. Notify the monitoring service and/or the Fire Department immediately. Tell them briefly what happened and what
    your current status is.
Phones: ____________________________     _________________________________
                                                     Fire Department                                                Monitoring Service
3. If the Fire Department is responding, be prepared to provide directions to arriving firefighters.
FOR TROUBLE ONLY
1. Notify the monitoring service and/or Fire department if this panel is connected to either one, and tell them
    what is happening.
2. Silence audible devices by unlocking and opening the panel and pressing the ACKNOWLEDGE/STEP key. The
    yellow system TROUBLE LED will remain on. Contact authorized service personnel immediately! (See Below).
WARNING!
DO NOT ALLOW TROUBLE CONDITIONS TO REMAIN LOGGED IN THE SYSTEM.
THE PROTECTION THE SYSTEM OFFERS HAS BEEN COMPROMISED, OR ELIMINATED WHEN A
TROUBLE CONDITION EXISTS.
To return to normal after an alarm
1. Do not enter the protected area until safe to do so.
2. Clear all initiating devices. Smoke detectors will not reset
    if there is still smoke in the area.
3. Reset the control panel (PRESS the RESET key)
Power failure or brownout
If AC power drops too low or fails, the AC POWER LED will go out,
the system TROUBLE LED will turn on, and the panel buzzer and
any other audible trouble devices will sound. Contact authorized
service personnel immediately. See below.
Manual activation (Fire Drill or otherwise)
Notification Appliance Circuits (NACs) can be activated by
pressing and holding the DRILL key for at least two seconds.
NOTE: You may want to disconnect municipal box by sliding
DISCONNECT switch, located on 4XTMF module, to its
disconnect position (to the right). If a DACT is con-
nected, notify the monitoring service before conducting
any fire drills or tests.
MS-9200UDLS/E Fire Alarm Control Panel
Operating Instructions
PANEL KEY - The key to open the panel can be found at the
following location:
NORMAL - Only the GREEN A.C. POWER LED is on.
All other LED's are off.  LCD display will read SYSTEM ALL
NORMAL.
Document #52773      Rev. A     11/04/05     ECN 05-680
THIS SHEET SHALL BE FRAMED ADJACENT TO
THE CONTROL PANEL
To test the lamps, LCD display and piezo sounder
Press and release the RESET key and check all LED's. Every LED
should be on, LCD shows all pixels on, piezo sounder beeps.
For more information, refer to the MS-9200UDLS/E Manual,
Document #52750. It is kept in the following location:
Alarm Silencing
Notification Appliance Circuits may be silenced by pressing the
ALARM SILENCE key. The ALARM SILENCED LED will turn on.
Subsequent alarms will reactivate circuits. Press the RESET key
to clear the "silenced" condition.
NOTE: Notification Appliance Circuits may be programmed as
nonsilenceable.  Also, Signal Silence Inhibit, if enabled, will
prevent silencing of NACs for one minute after an alarm (see
manual).
Name: _____________________________________
Company: _________________________________
Address: ___________________________________
Telephone Number: ________________________
In the event of trouble, contact the
local Fire-Lite Service Representative




DOC-1015d721:

Recommended:
Grand Tour LX, KDF-46E2000 - 46" Lcd Projection Hd-tv Grand Wega, 478306-00, Rascal 110

USI-1122L, FC700A, ZENITH GOLD 869 Series, I9030, GS506G
  • Why Te s t ?BACHARACH625 Alpha Drive, Pittsburgh, PA 152381-800-736-4666www.bacharach-inc.comIn Canada, call 1-800-328-5217Combustion testing todayis no longer an option.It’s a necessity.It used to be that fossil fuel-burning homeappliances could be adequately serviced byconducting visual tests. ...

    Model & Doc Type: Model 105 2

  • READ ALL INSTRUCTIONSThe smoke alarm has a recommended service life of at least 10 years under normal conditions.The smoke alarm uses an extremely small amount of a radioactive element in the ionizationchamber. Do not tamper with radioactive sealed source or try to repair the smoke alarmyourself. R ...

    Model & Doc Type: USI-1122L 6

  • www.emsgroup.co.ukRadio Detector BasePRESS HERE TOLOG ONIDENT63mm1 Pre Installation4 Power Device 3 Fix Mounting Plate2 Componentsdeviceunpowered(pins unlinked)devicepowered(both pins linked)!Installation must conform to applicable local installation codes and should only be installe ...

    Model & Doc Type: FireCell FCX-174-001 2

  • TrademarkAUTOOL Technology Co, Ltd. has registered its trademarks in different countries, thetrademark is . With regard to the other trademark, service logo, domain name,icon and company name mentioned in this manual, they shall all belong to AUTOOL and itsother affiliated company, in other coun ...

    Model & Doc Type: SDT 202 3

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Wheelock
SAFEPATH RSAPE-B
50 0.53 Mb 09/11
2 DSC
WLS906-433
2 0.15 Mb 25/03
3 Resolution
RE114
12 27/01
4 Hochiki
SLV Series
2 21/11
5 Arton
ASD-10QR
1 02/03
6 Det-Tronics
X5200
21 23/01
7 System Sensor
7251
4 20/04
8 sfty
Sense
12 12/11
9 LST
ECO1002
1 19/10
10 LST
GIF8-1
2 17/11

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Sub-Zero
Sub-Zero
72 0.78 Mb 25.11.2023
2 sauermann
Si-10
12 04.04.2024
3 AUMA
SA 16.2
80 06.01.2024
4 Sony
TA-NR1
19 01.01.2024
5 eSmart
LC3100C
10 09.03.2024
6 Sanyo
PLC-XM100
89 12.04.2024
7 Danfoss
852
2 07.12.2023
8 EMX
MVP D-TEK
14 27.01.2024
9 Maspro
UTB30HK
2 21.02.2024
10 HP
EliteDesk 705 G1
246 05.12.2023
Operating Impressions, Questions and Answers: