Specifications:265/265386-fortigate_fortigateasmfb4.pdf file (20 Apr 2024)
|
Fortinet FortiGate FortiGate-ASM-FB4 Network Router PDF Quick Start Manual (Updated: Saturday 20th of April 2024 09:08:40 AM)
Rating: 4.9 (rated by 68 users)
Compatible devices: FortiGate FortiGate-5002FB2, FortiWiFi FortiWiFi-50B, FORTIOS V3.0 MR7, FortiWLM 1000D, 100A, FortiBridge FortiBridge-1000, FortiGate 500A, FortiGate FortiGate-224B.
Recommended Documentation:
© Copyright 2007 Fortinet Incorporated. All rights reserved. Products mentioned in this document are trademarks or registered trade- marks of their respective holders. Regulatory Compliance FCC Class A Part 15 CSA/CUS 7 September 2007 Checking the Package Contents Installing the transceivers Installing the AMC module ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT QuickStart Guide FortiGate-ASM-FB4 Copyr ight 2007 Fortinet In corporated. All right s reserved. Tradem arks Produ cts m entio ned i n this docu ment are t radema rks. Q u i c k S t a r t G u i d e ASM-F B4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT ASM-FB4 LINK ACT 1 2 3 4 LINK ACT LINK ACT LINK HS OOS PWR OT ACT x4 SFP Transceivers The FortiGate ASM-FB4 module ships with four SFP SERDES SX 1000Mbps bre transceiv- ers that you must install for normal operation of the FortiGate ASM-FB4 module. The SFP transceivers are inserted into cage sockets numbered 1 to 4 on the FortiGate ASM-FB4 front panel. You can install the SFP transceivers before or after inserting the FortiGate ASM-FB4 module into a FortiGate unit. To complete this procedure, you need: • A FortiGate- ASM-FB4 module • Four SFP transceivers • To avoid any electrostatic discharge, install in a static free area. FortiGate ASM-FB4 modules must be protected from static discharge and physical shock. Only handle or work with FortiGate ASM-FB4 modules at a static-free workstation. Handling the SFP transceivers by holding the release Latch can damage the connector. Do not force the SFP transceivers into the cage slots. It is important to carefully seat the FortiGate ASM-FB4 module all the way into the chassis. Only then will the FortiGate ASM-FB4 module power-on. To complete this procedure, you need: • A FortiGate ASM-FB4 module • A FortiGate chassis with an empty AMC single-width (SW) opening. • To avoid any electrostatic discharge, install in a static free area. FortiGate ASM-FB4 modules are not hot swappable. The procedure for inserting the FortiGate ASM-FB4 module into a FortiGate chassis slot requires the FortiGate unit to be powered off. To avoid any electrostatic discharge (ESD) when handling FortiGate ASM-FB4 modules, install in a static free area. To insert a FortiGate ASM-FB4 module into a FortiGate chassis Ensure the FortiGate unit is powered off before proceeding. Remove the panel block on the FortiGate unit using the hot swap latch. Pull the latch on the ASM-FB4 module to the extended position. Insert the FortiGate ASM-FB4 module into the empty slot in the chassis. Ensure the Fortinet logo is right-side up. It should be on the upper-right corner of the module. Carefully guide the module into the chassis. Insert the module by applying moderate force to the front faceplate near the upper edge to slide the module into the slot. The module should glide smoothly into the chassis. If you encounter any resistance while sliding the module in, the module could be aligned incorrectly. Pull the module back out and try inserting it again. Press the hot swap latch to lock in the module. Power on the FortiGate unit. The hot swap (HS) LED turns on and then begins ashing. 1. 2. 3. 4. 5. 6. 7. 8. FortiGate-ASM-FB4 01-30005-0409-20070907 Connector Type Speed Protocol Description Ports 1 to 4 SERDES compatible SX ber 1000 Base-SX Ethernet Fiber network connections. If the transceiver does not easily slide in and click into place, it may not be aligned correctly or may be upside down. If this happens, remove the SFP transceiver, realign it or rotate it and slide it in again. To Install the transceivers Remove the caps from SFP cage sockets on the FortiGate ASM-FB4 front panel. Hold the sides of the SFP transceiver and slide SFP transceiver into the cage socket until it clicks into place. The FortiGate ASM-FB4 also supports SGMII copper gigabit (10/100/1000) transceivers. Use the following CLI command to enable this type of transceiver: cong system interface edit AMC-SW1/1 set mediatype serdes|sgmii end 1. 2. ASM-FB4 module ports AMC/1 IP: ____.____.____.____ AMC/3 IP: ____.____.____.____ Netmask: ____.____.____.____ Netmask: ____.____.____.____ AMC/2 IP: ____.____.____.____ AMC/4 IP: ____.____.____.____ Netmask: ____.____.____.____ Netmask: ____.____.____.____ Removing the AMC module Should you need to remove the ASM-FB4, shut down the FortiGate unit using proper shut down procedures. To remove the ASM-FB4 module Ensure the FortiGate unit is powered off before proceeding. To avoid any electrostatic discharge (ESD) when handling FortiGate ASM-FB4 modules, install in a static free area. Pull the hot swap latch on the right-hand side of the module to the extended position to unlock the module from the FortiGate unit. Gently pull the hot swap latch to remove the module. 1. 2. 3. 4. LED State Description HS Blue Ejection latch open. The module is ready for removal. Flashing Ejection latch opened during system operation. OOS LED currently not in use. PWR Amber The module is properly inserted in the FortiGate unit. Off The module is not receiving power from the FortiGate unit. OT LED currently not in use. LINK Green The correct cable is in use and the connected equipment has power. Off No link established. ACT Flashing Amber Network activity at this interface. Off No network activity at this interface.
Panasonic Reference Book: SC-PM50D (#C95E2Y)
SC-PM50D, 28, panasonic/sc-pm50d.pdf
Sharp Instruction LCD TV LC-32D44E (#FASKZ3)
LC-32D44E, 142, sharp/lc-32d44e.pdf
Projector Accessories QuickStand Series Instruction, #V867JD
QuickStand Series, 10, elite-screens/quickstand-series.pdf
R41121 Saw - #H374N4
R41121, 104, ridgid/r41121.pdf
PMS-LAN Surge Protector - #9I1U85
PMS-LAN, 76, energenie/pms-lan.pdf
Siemens Tutorial: QAX850 (#G7W5MV)
QAX850, 2, siemens/qax850.pdf
Samsung Tutorial Plasma TV PN63B590T5FXZA (#5416K3)
PN63B590T5FXZA, 2, samsung/pn63b590t5fxza.pdf
Ecoflam Instruction Burner MAX 15 (#112LKS)
MAX 15, 72, ecoflam/max-15.pdf
Refrigerator User Guide #MI2I26
REFRIGERATOR, 132, lg/refrigerator.pdf
Handbook (8468977, #4ARCW1)
8468977, 24, power-fist/8468977.pdf
Model No.Product DataWIREDRV082The heart of your connection-redundant secure small office networkA high-reliability Internet connection-sharing router and 8-port switch for small businessAdvanced SPI firewall protects your PCs from most known Internet attacksFeatures dual Internet ports for l ...
Model & Doc Type: RV082 2
Replace Chassis Components• Replace Fan Modules for Cisco 8201 Routers, on page 1• Replace Power Supply, on page 3Replace Fan Modules for Cisco 8201 RoutersThe fan module is designed to be removed and replaced while the system is operating without presenting anelectrical hazard or damage to th ...
Model & Doc Type: 8201 4
USBUSBcomes with GatewayNB620W GatewayNB620W Super-G Wireless Broadband GatewayThank you for choosing this NetComm Super G Wireless Gateway. Your gateway is pre-configured for easy installation. If you are not sure wheather your Gateway has the default setup, please reset the unit back to ...
Model & Doc Type: NB620W 2
Corporate Headquarters:Copyright © 2001. Cisco Systems, Inc. All rights reserved.Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USACisco 800 Series Router Cabling and SetupQuick Start GuideThis document describes the basic process of cabling and configuring t ...
Model & Doc Type: 2800 Series 12
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Yamaha | MB2000 |
2 | 0.04 Mb | 19/11 | |
2 | B+B SMARTWORK | SmartFlex SR305 |
56 | 13/04 | ||
3 | Trango Systems | TrangoLINK-45 |
60 | 1.76 Mb | 08/02 | |
4 | Qvis | G3-mini keyboard |
19 | 09/02 | ||
5 | RAD | HS-ETH/SW |
58 | 28/03 | ||
6 | NETGEAR | R6260 |
177 | 30/01 | ||
7 | D-Link | DCM-200 |
16 | 0.74 Mb | 03/04 | |
8 | Zoom | 2919 |
2 | 0.4 Mb | 04/12 | |
9 | Zhone | 6212 |
84 | 2.49 Mb | 13/03 | |
10 | ADJ | WiTECH8 |
2 | 10/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Amana | MVH230* |
24 | 2.39 Mb | 24.12.2023 | |
2 | ELRO | HIS20USB |
21 | 31.01.2024 | ||
3 | Nokia Siemens Networks | CPEi 800 Series |
40 | 09.10.2023 | ||
4 | GE | GSH25ISZSS |
2 | 11.10.2023 | ||
5 | Power Fist | 8308231 |
16 | 25.10.2023 | ||
6 | Grindmaster | 10H |
2 | 0.28 Mb | 02.01.2024 | |
7 | Electro-Voice | PRO-8A |
4 | 0.38 Mb | 28.12.2023 | |
8 | Hogtunes | FL7REV |
8 | 01.01.2024 | ||
9 | Echo | HCA-260 |
35 | 0.86 Mb | 18.04.2024 | |
10 | Sony | ICF-M88B Marketing |
2 | 0.27 Mb | 06.11.2023 |