Tripp Lite SNMPWEBCARD Manual 

Manual  for Tripp Lite SNMPWEBCARD Accessory, Adapter (1 pages)

Specifications:

268/268900-snmpwebcard.pdf file (13 Mar 2024)
  • Manufacturer: Tripp Lite
  • Category of Device: Accessory, Adapter
  • Document: SNMPWEBCARD, File Type: PDF Manual 
  • Updated: 13-03-2024
  • Count of Pages: 1
Download SNMPWEBCARD Manual (1 pages)

Read PDF Document Online:

Data: UPD 13th March 2024

Tripp Lite SNMPWEBCARD Accessory, Adapter PDF Manual  (Updated: Wednesday 13th of March 2024 08:32:44 PM)

Rating: 4.3 (rated by 67 users)

Compatible devices: PowerVerter PVINT375, OmniSmart HG, PowerVerter 200712159, SUPDMB20K, OMNIX350HG, SUPT60K, APS1024INT, SMART2200NET.

Recommended Documentation:

Text Version of Tripp Lite SNMPWEBCARD Accessory, Adapter Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 13 March 2024)


Complete Manual & Quick Start Guide
Internal UPS Web Management Adapter Card
Model: SNMPWEBCARD
1111 W. 35th Street,  Chicago, IL 60609 USA
Customer Support: (773) 869-1234  • www.tripplite.com
1) Connecting SNMPWEBCARD to UPS
a. Turn the UPS on.
b. Unscrew and remove the accessory slot cover plate on the back of the 
UPS.
c. Slide the SNMPWEBCARD into the accessory slot. Using an Ethernet 
cable, connect the SNMPWEBCARD to the LAN. The SNMPWEB
CARD by  default is configured for DHCP and will automatically 
obtain an IP address provided there is a DHCP server.
d. Proceed to Step 6b. (Only follow Steps 2-5 if the SNMPWEBCARD 
did NOT automatically receive an IP address when you performed 
Step 1 above.)
2) Manually Configuring SNMPWEBCARD
a. Disconnect Ethernet cable and remove the SNMPWEBCARD 
from the accessory slot.
b. Set the SNMPWEBCARD's jumpers. For most Tripp Lite UPS models, 
set to jumper position 1 (see Fig.1). This is the card's default position. 
For models listed below with their corresponding series 
numbers, set to jumper position 2 (see Fig. 2). 
Note: Series numbers can be found on the back of the UPS.
3) Preparing Computer for Terminal Mode Configuration
a. Open a VT-100-compatible terminal emulation program on your 
computer.
b. Configure the terminal emulation program to use the COM port on your 
computer that will connect to the SNMPWEBCARD, and to use the 
following settings:
Baud Rate: 9600 Stop Bit: 1
Data: 8 bits Flow Control: none
Parity: none
4) Installing SNMPWEBCARD in UPS
a. Unscrew and remove the accessory slot cover plate on the back of the UPS.
b. Slide the SNMPWEBCARD into the accessory slot.
c. Using the cable (73-1025) provided, connect the serial interface 
connector to the COM port of the computer. Then connect the mini din 
8 (circular) connector to the middle port of the SNMPWEBCARD. 
Note: To prevent damage to the connector, make sure that the pins are 
properly aligned.
d. Using an Ethernet cable, connect the SNMPWEBCARD to the LAN.
5) Configuring SNMPWEBCARD in Terminal Mode
a. When the configuration main menu appears on your computer screen, 
you will be prompted to accept or modify current setting. Type M (modify).
b. A password prompt will appear. Type the default terminal password:
TrippLite.
c. Reset Configuration to default values (Y/N) will appear. Type N (no) and 
press ENTER.
d. Network Interface Parameters will appear. You will be prompted with 
Should target obtain IP settings from the network? Type N (no) and 
configure the card to your networks subnets. If you do not know what IP
address to give the SNMPWEBCARD, contact your system administrator.
e. Save settings. The card will then reboot; depending on the selected 
configuration settings, it will take 2-5 minutes for the card to become 
initialized.
6) Preparing SNMPWEBCARD for Operation
a. Remove the cable connecting the SNMPWEBCARD to the computer.
b. Test network configuration by pinging the IP address given to the 
SNMPWEBCARD.
c. If test is successful, replace the UPS accessory slot plate and secure it 
with screws to hold the SNMPWEBCARD firmly in position.
7) Connecting to the SNMPWEBCARD Using a Web Browser
a. Open a web browser on any computer on the LAN.
b. Enter the IP address that was assigned to the SNMPWEBCARD. You 
will be prompted to enter a username and password. Enter the default 
username: admin. Leave the password field blank.
c. The UPS status screen will appear. Additional configurations may be 
specified from this screen: email, SNMP, shutdown parameters and more.
PLEASE READ CAREFULLY BEFORE INSTALLING SNMPWEBCARD 
SNMP: The RFC1628.mib and Tripplite.mib
(provided on the accompanying CD) must be
loaded into every management station that will
monitor the UPS via SNMP.
Documentation: The full SNMPWEBCARD
User's Guide is provided on the accompanying
CD. The User's Guide may also be accessed on
line at www.tripplite.com
Support: If you have any questions or prob-
lems, contact a Tripp Lite Network Product
Specialist at (773) 869-1599, between the hours of
8:30 AM and 5:00 PM CST.
200503171  93-2253

2
4

13
U5
Link Positions
2

4
1

3
Jumper Position 2
U5
Link Positions
Fig. 1
Fig. 2
Tripp Lite 
UPS System Model Series Number
SMART1400RM2U AGSM1400Y2U29
SMART1500RM2U AGSM1400Y2U29
SMART1500RMXL2U AGSM1400Y2U29
SMART2200RM2U AGSM2200Y2U29
SMART2200RMXL2U AGSM2200Y2U29
SM2200RM2U-L520 AGSM2200Y2U29
Tripp Lite 
UPS System Model Series Number
SM2000RMX3U AGSM2200Y2U29
SMART2600RM2U AGSM3000Y2U29
SMART3000RM2U AGSM3000Y2U29
SMART3000RMXL2U AGSM3000Y2U29
SMART3000RM2U AGSM3000Y2U29
This product designed and engineered in the U.S.A.
WARRANTY
REGISTRATION
Register on-line today for a 
chance to win a FREE Tripp Lite 
product! www.tripplite.com/warranty
Jumper Position 1
(Default)
Link Color Link Indicator
Off No Network
Flashing Amber 100 Mbs Network Connection
Flashing Green 10 Mbs Network Connection
Status Color Status Indicator
Off Not Initialized
Steady Green Initialized & Operational
Flashing Amber Error-Not Initialized
Link Status
200503171 93-2253 SNMP Webcard QSG.qxd  8/15/2005  10:06 AM  Page 1





DOC-ea42c7f8:

Recommended:
Tracer VV550, SP-THD5S, VE155 - 15" LCD Monitor, PEARL

XA-120IP, 100014153, RF-PRACDC, PAU09, ATA-171, CCMA-2DAR
  • DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) ________________________________________________________________________________________________________________________________________________________ SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual ...

    Model & Doc Type: SIMATIC ET 200SP 24

  •  Kurzübersicht / Sicherheitshinweise Technische Details: Eingangsspannung: 90 – 264 V AC (47-63Hz) Ausgangsspannung: 12VDC max. 5A (60 Watt) Betriebstemperatur: 0-40 Grad Celsius Luftfeuchtigkeit: 10% - 90% (nicht kondensierend) Mechanische Abmaße : 252mm x 241 mm x ...

    Model & Doc Type: 100014153 2

  • 1 13 Alternative Rack Mounting (4-Post) Version 2, April 2001 Introduction This chapter provides the instructions for mounting the HP Netserver in a four-post (column) HP Systems rack. Figure 13-1 shows the Systems rack. If you have the newer 4-post HP System/E or System/U racks, go to Chapter 8. ...

    Model & Doc Type: D7171A - NetServer - LPr 13

  • Copyright©2011 Design Gateway Co,.Ltd. All rights reserved. HSMC SATA RAID board [AB12-HSMCRAID] Manual [Ver1.0E] Introduction Thank you for choosing HSMC SATA RAID board [Part Number: AB12-HSMCRAID] (“RAID board” in this manual.) The RAID board is compliant with HSMC standa ...

    Model & Doc Type: AB12-HSMCRAID 6

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Eaton
Series NRX
12 14/12
2 NETGEAR
WG111T - 108 Mbps Wireless USB 2.0 Adapter
89 28/03
3 NETGEAR
GA620 - PCI Fiber Card
2 29/02
4 Nikon
EH-54
2 29/01
5 Linksys
Fax Adapter
4 02/11
6 Repotec
UBM302G
8 02/04
7 D-Link
DSL-500
54 0.78 Mb 14/04
8 Dension
Gateway Five
4 30/11
9 D-Link
DFE-538TX
63 4.15 Mb 19/02
10 Corinex
Powerline Router
111 5.82 Mb 01/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 HP
Designjet 1000
286 14.76 Mb 31.12.2023
2 Vivitar
DP1500 X
35 0.73 Mb 28.11.2023
3 Innovative Technology
ITVS?650
14 19.01.2024
4 LG
26LS3500
42 12.04.2024
5 Morso
Forno
28 30.03.2024
6 Hitachi
27CX7B
52 2.06 Mb 02.01.2024
7 Apple
iTunes
8 19.04.2024
8 Honeywell
XENON 1900
266 20.03.2024
9 Mercedes-Benz
2005 CL-Class
458 17.01.2024
10 Scarlett
SC-294
45 11.10.2023
Operating Impressions, Questions and Answers: