Roland DR-50 Owner's Manual

Owner's Manual for Roland DR-50 Electronic Keyboard, Microphone (1 pages)

Specifications:

324/324765-dr50.pdf file (23 Nov 2023)
  • Manufacturer: Roland
  • Category of Device: Electronic Keyboard, Microphone
  • Document: DR-50, File Type: PDF Owner's Manual
  • Updated: 23-11-2023
  • Count of Pages: 1
Download DR-50 Manual (1 pages)

Read PDF Document Online:

Data: UPD 23rd November 2023

Roland DR-50 Electronic Keyboard, Microphone PDF Owner's Manual (Updated: Thursday 23rd of November 2023 02:25:06 PM)

Rating: 4.9 (rated by 45 users)

Compatible devices: X-6, KR-115, UM-2G, DR-80C, A-37, RS-70, C-180, JX-8P.

Recommended Documentation:

Text Version of Roland DR-50 Electronic Keyboard, Microphone Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 23 November 2023)


Owner’s Manual
We’d like to take a moment to thank you for purchasing the Roland DYNAMIC
MICROPHONE.
Before using this unit, carefully read the section entitled: “IMPORTANT
NOTES.” This section provides important information concerning the proper
operation of the unit. Additionally, in order to feel assured that you have gained
a good grasp of every feature provided by your new unit, this manual should be
read in its entirety. The manual should be saved and kept on hand as a
convenient reference.
Copyright © 2005 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form
without the written permission of ROLAND CORPORATION.
■ IMPORTANT NOTES
• Howling could be produced depending on the location of microphones
relative to speakers. This can be remedied by:
1. Changing the orientation of the microphone(s).
2. Relocating microphone(s) at a greater distance from speakers.
3. Lowering volume levels.
• Protect the unit from strong impact. (Do not drop it!)
• Do not open or perform any internal modifications on the unit.
• Never use or store the unit in places that are:
• Subject to temperature extremes (e.g., direct sunlight in an enclosed
vehicle, near a heating duct, on top of heat-generating equipment); or are
• Damp (e.g., baths, washrooms, on wet floors); or are
• Humid; or are
• Exposed to rain; or are
• Dusty; or are
• Subject to high levels of vibration.
• When using the microphone with the stand recommended by Roland (ST-
210 or ST-259), make sure the legs of the tripod are opened wide enough to
keep the equipment from falling over. The stand must be carefully placed so
it is level and sure to remain stable.
• For everyday cleaning wipe the unit with a soft, dry cloth or one that has
been slightly dampened with water. To remove stubborn dirt, use a cloth
impregnated with a mild, non-abrasive detergent. Afterwards, be sure to
wipe the unit thoroughly with a soft, dry cloth.
• Never use benzine, thinners, alcohol or solvents of any kind, to avoid the
possibility of discoloration and/or deformation.
WARNING
• Keep the included Screw Adapter in a safe place
out of children’s reach, so there is no chance of
them being swallowed accidentally.
■ FEATURES
• Hyper Cardioid handheld mic enhanced shock-absorption for unit protection
and reduced mic handling noise
• Double-Screen structure to reduce breath noise
■ OPERATION
1. Connect the XLR connector to the microphone.
2. Connect the other side (standard phone jack) of the cable to the input jack of
the unit you use, such as mixer.
3. If you wish to install the microphone to a microphone stand, use the supplied
microphone holder. If the microphone holder does not fit the stand, try
exchanging the screw adapter. (U 5/8, W 3/8)
■ PIN ASSIGNMENT
The pin assignment for XLR type connectors is as shown below. Before
making any connections, make sure that this pin assignment is compatible with
that of all your other devices.
■ POLAR PATTERNS
■ FREQUENCY RESPONSE
■ MAIN SPECIFICATIONS
Type..........................................................................................................Dynamic
Frequency Response .....................................................................90—16,000 Hz
Output Impedance.......................................................................................300 Ω
Polar Patterns ...............................................................................Hyper Cardioid
Sensitivity ................................................................-54 dB (0 dB=1 V/Pa, 1 kHz)
Dimensions (dia head × length × dia grip) ..........................50 × 192.5 × 22 mm
Weight............................................................................................................355 g
Accessories
Microphone cable (4.5 m) ..............................................................................1
Microphone holder .........................................................................................1
Screw adapter (5/8"–27, 3/8"–16) ..................................................................1
Carrying case ..................................................................................................1
* In the interest of product improvement, the specifications and/or appearance of
this unit are subject to change without prior notice.
192.5mm 
7–5/8"
22mm 
7/8"
50mm 
2"

1kHz

MICROPHONE  MICROPHONE CABLE 
GND GND
GND HOT
HOT HOT
COLD COLD(GND)
12
3
21
3

XLR TYPE CONNECTOR 1/4" PHONE PLUG
DOUBLE CONDUCTOR SHIELD

MICROPHONE HOLDER

SCREW ADAPTER 
(5/8"–27, 3/8"–16)

DR_50E.qx  05.6.6 6:04 PM  ページ 1




DOC-be28e914:

Recommended:
T2150, Kix, A1600BT, PP 900SSKLT

Studio Pro 126-03, KK 131, M3, Q8x, CTG--1, SPM-1700
  • Page 1 of 3 Pairing button Remote Microphone Connection Procedures for the Kanso – Roger Touchscreen as Transmitter 1. Pair the MM2+ to the Kanso. (Pairing only needs to be done once, unless MM2+ has been paired to another processor) a. Turn off the Kanso by pressing and holding th ...

    Model & Doc Type: MM2+ 3

  • 27B3122 (BD)E2002, Shure IncorporatedPrinted in U.S.A.User GuideTrademark Notices: The circular S logo, the stylized Shure logo, and the word“Shure” are registered trademarks of Shure Incorporated in the United States.“ShureLock” is a trademark of Shure Incorporated in the United States. ...

    Model & Doc Type: KSM44 12

  • SuperCMIT 2 USuper-Richtrohr mit DSPSuper Shotgun Microphone with DSPBedienungsanleitungUser Guide - page 11Inhaltsverzeichnis SeiteAllgemeines 2Einsatzgebiete 3Anschließen / Bedienelemente 3Gain / Limiter 4Wichtige Hinweise 4Hinweise zur EMV 5Pflege und Wartung 5Technische Daten 6Firmware ...

    Model & Doc Type: supercmit 2 u 20

  • www.sandberg.itWarrantyThere is a ve-year warranty on your Sandberg product.Please read the warranty terms and register your new Sandberg product at www.sandberg.it/warranty.For information on handling electronic waste, see www.sandberg.it/weeeUser guide126-03http://helpdesk.sandberg.it ...

    Model & Doc Type: Studio Pro 126-03 17

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 RODE Microphones
VideoMic Pro
16 1.5 Mb 11/12
2 Bogen
Microphones
8 1.44 Mb 12/04
3 Electro-Voice
MS2500
4 0.55 Mb 25/12
4 Neumann.Berlin
BCM104
5 20/02
5 Sena
SMH5 FM
41 28/12
6 Sennheiser
100 Series
1 0.1 Mb 23/12
7 Azden
WR-PRO
4 20/10
8 Soundfield
ST450 MKII
28 12/02
9 BRUEL & KJAER
4188
219 18/10
10 AKG
WMS 40 PRO FLEXX
104 0.87 Mb 17/04

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Weslo
SPARRING SYSTEM
16 07.04.2024
2 Targus
Mac AMP11
10 1.32 Mb 17.02.2024
3 New Buck Corporation
70
43 24.01.2024
4 Fujitsu Siemens Computers
P50-2H
44 0.92 Mb 14.04.2024
5 HP
Presario 6200 - Desktop PC
20 0.13 Mb 21.02.2024
6 Honeywell
RF 20
2 19.12.2023
7 Beko
HIMW 64225 S
80 19.03.2024
8 Crow
Power Wave - ’ST’
44 18.12.2023
9 Frigidaire
FRS24ZRH
21 01.12.2023
10 Inter Page
VP100
8 21.01.2024
Operating Impressions, Questions and Answers: