Specifications:390/390528-tb167_application_guide.pdf file (05 Apr 2024)
|
Peco TB167 Thermostat PDF Application Manual (Updated: Friday 5th of April 2024 01:31:23 PM)
Rating: 4.5 (rated by 35 users)
Compatible devices: T8532-IAQ, T8000 series, TA167-006, T168, TA180-001, Performance Pro T12000 Series, Peco RW205, TH-109.
Recommended Documentation:
hREAD THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS THERMOSTAT. hFailure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. hTo avoid electrical shock or damage to equipment, disconnect power before installing or servicing. hTo avoid potential fire and/ or explosion do not use in potentially flammable or explosive atmospheres. hRetain these instructions for future reference. This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by PECO, Inc. You must review your application and national and local codes to assure that your installation will be functional and safe. WARNING CAUTION 1 Use Copper wire only, insulate or wire nut all un-used leads. © COPYRIGHT PECO, INC. ALL RIGHTS RESERVED P/N 68817 3220-1465 Rev 0 Page 1 THERMOSTAT OPERATION The T167 has a proportional band width of 2°F. Temperature Control Range: 50 - 90 F TA167: A HEAT-OFF-COOL system switch manually selects heating or cooling mode. In the HEAT position only the heat output cycles with demand. In the COOL position only the cool output cycles with demand. In the OFF position heating and cooling output are off. A ON-OFF system switch allow direct cycling between heat output and the cool output and should be used for either heat only or cool only applications. A changeover switch should be used if both outputs are used on TA167 models with ON-OFF switches. TB167: A ON-OFF system switch enables auto-changeover of heating and cooling mode. In the ON position thermostat activates heating or cooling output dependant upon the relationship between the set point and the ambient temperature. Heat OFF to cool ON (or Cool OFF to Heat ON) changeover is 3°F. After a changeover excursion has occurred the thermostat will resume controlling at the set point. In the OFF position heating and cooling outputs are off. FAN: Fan Operation is switched on or off with the system switch. Manual selection of up to three fan speeds are available on models with Fan Switches. Fan circuitry is electrically separate from thermostatic circuitry. 1. Install the T167 with the two furnished mounting screws to a standard 2" x 4" electrical box, 4-11/16" x 2-1/8" square device box with a 2" x 4" adapter ring or to a 4" x 4" box with accessory adapter plate. 2. For wall installations, mount the thermostat on an inside wall approximately 5 feet above the floor. The location should provide circulation at average room temperature. Avoid direct sunlight or sources of hot or cold air in the room or wall. 3. Remove the knob and then the cover. Mount thermostat base assembly to the outlet box using the screws provided, tighten the screws evenly but do not over tighten. Connect wires as noted. 4. The cover may limit system switch movement. Switch position should not be changed after the cover is removed to assure that the cover can be reinstalled. 5. To use a remote sensor on units that have local sensing capability, remove jumper JP-1 to disable local sensing. Failure to remove JP-1 will cause improper operation of the thermostat. 6. Reinstall the cover assembly. Install cover locking screw provided. Reinstall the knob. 7. Checkout: After wiring and installation are complete, energize the system and check the operation. Adjust the thermostat as necessary to complete at least one cycle. Be sure the thermostat and all other equipment are functioning correctly. JP1 4 1 2 1 2 3 1 2 3 4 TB1 TB2 TB3 REMOVE JP1 WHEN USING A REMOTE SENSOR TERMINAL BLOCK TB2 INSTALL COVER LOCKING SCREW TERMINAL BLOCK TB3 TERMINAL BLOCK TB1 LINE or LOW VOLTAGE CONNECTIONS LOW VOLTAGE CONNECTIONS TB 2 TB 1 TB 3 HEAT 0 - 10 VDC COOL 0 - 10 VDC VOLTAGE RATING FAN AND SYSTEM SWITCHES INDUCTIVE FLA LRA RESISTIVE AMPS PILOT DUTY THERMOSTATIC OUTPUTS 24 VAC NA NA NA 24 VA 0 - 10 VDC 120 VAC 5.8 34.8 6.0 125 VA NA 240 VAC 2.9 17.4 5.0 125 VA NA 277 VAC 2.4 14.4 4.2 125 VA NA LO MED HI L1 FAN L2 OR FAN NEUTRAL 24 VAC 1 24 VAC 2 REMOTE PROBE 2 REMOTE PROBE 1 24 VAC XFMR 1 2 3 5 1 2 3 4 1 2 0-10 VDC THERMOSTAT TA167 / TB167 5 4 NO CONNECTION
Automobile Handbook #81IUK3
2009 S-Class, 616, mercedes-benz/2009-s-class.pdf
Wireless Router R 850 Document, #TOUL89
R 850, 65, sprint/r-850.pdf
Reference Book (CNGE2+2SMS, #PE6Z1T)
CNGE2+2SMS, 8, comnet/cnge22sms.pdf
#O437J1: Multivent TBM User Manual
Multivent TBM, 6, truma/multivent-tbm.pdf
Duerkopp Adler Guide: 173 (#5392PQ)
173, 16, duerkopp-adler/173.pdf
WAP121 Wireless Access Point - #93J446
WAP121, 155, cisco/wap121.pdf
TV Reference Book #9G2N43
MD20H63, 35, toshiba/md20h63.pdf
Battery Pack InfoLITHIUM NP-QM71D Guidance, #932HSX
InfoLITHIUM NP-QM71D, 2, sony/infolithium-np-qm71d.pdf
Motorola Two-Way Radio Manual (#156811)
MOTOTRBO DP4800, 540, motorola/mototrbo-dp4800.pdf
Reference Book (F755-3D320, #45F851)
F755-3D320, 4, toshiba/f755-3d320.pdf
Store this manual for future referenceª$MJNBUF5FDIOPMPHZ$PSQPSBUJPOt.BEFJO$IJOB 71100N-110-01Read all instructions before proceeding.Non-Programmable Thermostats71100N For 1 Heat / 1 Cool Systems73200N For Systems Up to 3 Heat / 2 CoolModel numb ...
Model & Doc Type: 71100N 20
Touchscreen thermostat programming guide (8259)[email protected] the wiring guide video on our website1543267°C°C°C°CPower buttonClock button/BacklightMenu buttonDown buttonUp button1 Toaccessadvancedsettingsswitchtheunitob ...
Model & Doc Type: 8259 2
I]Z=GI)"OL^hVl^gZaZhhZaZXigdc^XWViiZgnedlZgZYgddbi]ZgbdhiVii]VijhZh^ciZgdeZgVWaZild"lVnG;bZh]cZildg`^c\iZX]cdad\nidegdk^YZdei^bjbXdb[dgil^i]XadhZXdcigdad[i]ZZcZg\njhZYid]ZVii]Z]dbZ ...
Model & Doc Type: HRT4-ZW 12
Description: Alfa(net) 75 RTDF -50/+50°C Pages: 8 Doc.no: 150014 Type: Manual By: BVDB Version: 1.0 File: Do150014 ALFANET 75 RTDF -50+50°C V10 EN.docx Signed: Date: 19-01-2015 VDH Products BV Manual ALFA(NET) 75 RTDF -50/+50°C 1 Function T ...
Model & Doc Type: ALFA 75 RTDF 8
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | VDH | ALFA 35 DP |
4 | 15/02 | ||
2 | VDH | ALFA 75 RTDF |
8 | 19/04 | ||
3 | Watts | Tekmar 563 |
12 | 24/02 | ||
4 | Atag | One |
2 | 04/12 | ||
5 | RS PRO | 124-1045 |
3 | 27/02 | ||
6 | Honeywell | S963D |
6 | 0.46 Mb | 20/04 | |
7 | Fujitsu | UTY-TTRX |
9 | 17/01 | ||
8 | Megmeet | MTC-04-NVT |
6 | 09/02 | ||
9 | Pro1 IAQ | T755 |
6 | 26/11 | ||
10 | Honeywell | XE70 Series |
4 | 10/02 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Sirius XM RAdio | vehicle kit |
2 | 0.95 Mb | 05.02.2024 | |
2 | Pari | LC plus |
16 | 24.03.2024 | ||
3 | Velleman | CAMCOLVCN |
31 | 13.10.2023 | ||
4 | Samsung | WF393BTPAWR/A1-0001 |
132 | 01.12.2023 | ||
5 | Honeywell | ADEMCO 5821 |
4 | 05.03.2024 | ||
6 | Akai | AMP-10 |
58 | 01.12.2023 | ||
7 | Elta | SE101 |
29 | 0.44 Mb | 19.03.2024 | |
8 | AMX | MET-13 |
1 | 0.09 Mb | 24.01.2024 | |
9 | GE | 28127FE1 |
1 | 0.49 Mb | 21.03.2024 | |
10 | Whirlpool | MT2070XAB |
44 | 2.3 Mb | 24.10.2023 |