Whirlpool LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Manual, Product Dimensions

Manual, Product Dimensions for Whirlpool LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Dryer, Other (1 pages)

Specifications:

197/197111-nbspltg5243dq.pdf file (01 Dec 2023)
  • Manufacturer: Whirlpool
  • Category of Device: Dryer, Other
  • Document: LTG5243DQ - 24" Twin Washer/Dryer Laundry Center, File Type: PDF Product Dimensions
  • Updated: 01-12-2023
  • Count of Pages: 1
Download LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Manual (1 pages)

Read PDF Document Online:

Data: UPD 1st December 2023

Whirlpool LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Dryer, Other PDF Product Dimensions (Updated: Friday 1st of December 2023 08:50:21 PM)

Rating: 4.4 (rated by 94 users)

Compatible devices: WVP5000SQ0, WTW4900X, ATW4475V, 3347020, LSR5121JQ0, Gold GGQ9800PW3, W10151595B, LA4400XS.

Recommended Documentation:

Text Version of Whirlpool LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Dryer, Other Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 01 December 2023)


®
24" (61 cm) Gas Washer/Dryer
PRODUCT MODEL NUMBER PRODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
LTG5243D
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.
Ref. W10222384
10-30-08
For closet installation, with a door, minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent ventilation openings
are acceptable.

15 "
(39.1 cm)
71 ¾"
(182.2 cm)
*27 ¼"
(69.2 cm)
23 "
(60.6 cm)
32 "
(81.6 cm)
3
⁄8
1
⁄8
7
⁄8

*Required spacing
**Rear clearance may be 0" (0 cm) when house exhaust system 
is lined up directly with dryer exhaust.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
1
"
(2.5 cm)
     
 
1"
(2.5 cm)
AB C
3" (7.6 cm)
3" (7.6 cm)
1
"
    
 (2.5 cm)
23 "
(60.6 cm)
24 in.
2 
(155 cm
2
)
48 in.
2 
(310 cm
2
)
   1"*
(2.5  cm)
27¼"
 (69.2  cm)
5"**
(12.7  cm)
7
⁄8

* Most installations require a
minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust
vent with elbow.
DRAIN SYSTEM
Standpipe drain system - wall or floor 
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The
minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" 
(5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" 
(2.4 m) from the bottom of the washer.
Laundry tub drain system 
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub
must be at least 34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the
bottom of the washer.
Floor drain system
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer.
Additional hoses might be needed.
EXHAUST VENTING
Gas supply: This washer/dryer is equipped for use with Natural
gas. It is design-certified by CSA International for LP (propane or
butane) gases with appropriate conversion.
Gas supply line must include 1/8" NPT minimum plugged tapping
accessible for test gauge connection, immediately upstream of the gas
supply connection to the dryer. 1/2" IPS pipe is recommended. 3/8"
approved aluminum or copper tubing is acceptable for lengths under
20 ft (6.1 m) if local codes and gas supplier permit. If you are using
Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m)
should use larger tubing and a different size adapter fitting. Gas
supply line coupling must be 34" (864 mm) to 37" (940 mm) from the
floor. 
Must include a shutoff valve: An individual shutoff valve must be
installed within six (6) feet (1.8 m) of the washer/dryer in accordance
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The location
should be easy to reach for opening and closing.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON®† tape.
Electrical: A 120-volt, 60 Hz, AC only, 15- or 20-amp, fused
electrical supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit serving
only this appliance be provided. 
Exhaust venting: Exhaust your dryer to the outside. Use a heavy
metal vent. Do not use plastic or metal foil vent. 4" (10.2 cm) heavy
metal exhaust vent and clamps must be used. DURASAFE™ venting
products are recommended. Exhaust outlet hood must be at least 12"
(30.5 cm) from the ground or any object that may be in the path of
the exhaust.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows
and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows
you will need.

Vent Length Chart
NOTE:
 Side exhaust adds a 90° turn inside the washer/dryer. To 
determine maximum exhaust length, add one 90° turn to the 
chart.
No. of 
90° turns 
or elbows 
Type of Vent Box or 
Louvered 
hoods
Angled 
hoods
0 Rigid metal
43  ft (13.1 m) 36 ft (11.0 m)
1 Rigid metal
33 ft (10.1 m) 26 ft (7.9 m)
2 Rigid metal
23 ft (7.0 m) 16 ft (4.9 m)

 1. Louvered hood style
 2. Box hood style
     4"
(10.2 cm)
      4"
(10.2 cm)
2
1

   4"
(10.2 cm)
(6.4 cm)

Angled hood style





DOC-97ec54af:

Recommended:
VmWare ESX Server 2.12 Deployment, page 8z, STR-D560Z, FPM-3191G

AQD1170D 697 I, MLE20PRBZW1, ZWD 91683NW, WDS872, GLGT1142CS1, FES17
  • INSTAI ATIONINSTRUCTIONSCOMMERCIAL STACKED WASHER/DRYERGAS OR ELECTRICINSTRUCTIONSD'INSTALLATIONLAVEUSE/SECHEUSE SUPERPOSEESUSAGE COMMERCIAL/k GAZ OU t_LECTRIQUEINSTRUCCION.ESINSTALACIONLAVADORA/SECADORA COMERCIALESAPILADASA OASO ELt CTRICASTABLE OF CONTENTSPageStacked Washer/Dryer ...

    Model & Doc Type: MLE20PRBZW1 120

  • NA1 www.aristonappliances.usUser guideContentsDescription, 2Important Safety Instructions, 3-4Your safety and that of your familyWarnings about installationTechnical detailsUnpacking, Installation, 5-6-7-8-9Unpacking and levellingRemove the shipping boltsWater and Electric connect ...

    Model & Doc Type: AW 125 23

  • EX. RINSE103°MOTORSTARTBLK/REDREDBLK/HEATERTHERMOSTAT2 KCAUTION: DISCONNECT ELECTRIC CURRENT BEFORE SERVICING. LABELALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.VERIFY PROPER OPERATION AFTER SERVICING.THERMOSTATCONT ...

    Model & Doc Type: GLGT1142CS1 1

  • 1GBEnglish,1ContentsInstallation, 2-3Unpacking and levelling, 2Electric and water connections, 2-3The first wash cycle, 3Technical details, 3Washer-dryer description, 4-5Control panel, 4Leds, 5Starting and Programmes, 6Briefly: how to start a programme, 6Programme table, 6Personalisations, ...

    Model & Doc Type: WIDL 106 12

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 LG
FWV796 TSE Series
60 27/02
2 Hobart
UW50 ML-27838
16 1.01 Mb 15/10
3 LG
DLE2512W
45 07/02
4 Kenmore
363.61542
60 21/02
5 Siemens
WD15H542EU
44 02/02
6 Splendide
2100XC
2 16/01
7 Asko
W6661
2 0.05 Mb 26/12
8 Frigidaire
FAQG7011LB
2 0.42 Mb 23/01
9 Frigidaire
FEZ831CFS1
13 1.55 Mb 08/11
10 Alliance Laundry Systems
SWD455C SVG
50 21/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Vibe
LA4
8 2.22 Mb 14.04.2024
2 Zanussi
MC 20 MB
23 1.82 Mb 01.04.2024
3 Sony
PMW-200
134 11.03.2024
4 Melissa
16190012
25 27.12.2023
5 Chauvet
DJ Bank
13 1.08 Mb 05.10.2023
6 Generac Power Systems
004917-5
48 6.24 Mb 03.03.2024
7 Yamaha
R-9
20 2.49 Mb 23.10.2023
8 Nice
EDSWG/A
2 09.03.2024
9 Visionhitech
VQ29SFHD2
2 04.03.2024
10 OHAUS
Scout Pro
40 25.03.2024
Operating Impressions, Questions and Answers: