Specifications:197/197111-nbspltg5243dq.pdf file (01 Dec 2023)
|
Whirlpool LTG5243DQ - 24" Twin Washer/Dryer Laundry Center Dryer, Other PDF Product Dimensions (Updated: Friday 1st of December 2023 08:50:21 PM)
Rating: 4.4 (rated by 94 users)
Compatible devices: WVP5000SQ0, WTW4900X, ATW4475V, 3347020, LSR5121JQ0, Gold GGQ9800PW3, W10151595B, LA4400XS.
Recommended Documentation:
® 24" (61 cm) Gas Washer/Dryer PRODUCT MODEL NUMBER PRODUCT DIMENSIONS RECESSED AREA AND CLOSET INSTALLATION LTG5243D Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10222384 10-30-08 For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. 15 " (39.1 cm) 71 ¾" (182.2 cm) *27 ¼" (69.2 cm) 23 " (60.6 cm) 32 " (81.6 cm) 3 ⁄8 1 ⁄8 7 ⁄8 *Required spacing **Rear clearance may be 0" (0 cm) when house exhaust system is lined up directly with dryer exhaust. A. Recessed area B. Side view - closet or confined area C. Closet door with vents 1 " (2.5 cm) 1" (2.5 cm) AB C 3" (7.6 cm) 3" (7.6 cm) 1 " (2.5 cm) 23 " (60.6 cm) 24 in. 2 (155 cm 2 ) 48 in. 2 (310 cm 2 ) 1"* (2.5 cm) 27¼" (69.2 cm) 5"** (12.7 cm) 7 ⁄8 * Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. DRAIN SYSTEM Standpipe drain system - wall or floor The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available. The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the bottom of the washer. Laundry tub drain system The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer. Floor drain system The floor drain system requires a siphon break that may be purchased separately. The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed. EXHAUST VENTING Gas supply: This washer/dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion. Gas supply line must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas supply connection to the dryer. 1/2" IPS pipe is recommended. 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. If you are using Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting. Gas supply line coupling must be 34" (864 mm) to 37" (940 mm) from the floor. Must include a shutoff valve: An individual shutoff valve must be installed within six (6) feet (1.8 m) of the washer/dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The location should be easy to reach for opening and closing. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. Electrical: A 120-volt, 60 Hz, AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this appliance be provided. Exhaust venting: Exhaust your dryer to the outside. Use a heavy metal vent. Do not use plastic or metal foil vent. 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. Vent Length Chart NOTE: Side exhaust adds a 90° turn inside the washer/dryer. To determine maximum exhaust length, add one 90° turn to the chart. No. of 90° turns or elbows Type of Vent Box or Louvered hoods Angled hoods 0 Rigid metal 43 ft (13.1 m) 36 ft (11.0 m) 1 Rigid metal 33 ft (10.1 m) 26 ft (7.9 m) 2 Rigid metal 23 ft (7.0 m) 16 ft (4.9 m) 1. Louvered hood style 2. Box hood style 4" (10.2 cm) 4" (10.2 cm) 2 1 4" (10.2 cm) (6.4 cm) Angled hood style
Pages: 12
Pages: 8
Pages: 1
Pages: 18
Pages: 28
STR-D560Z Stereo Receiver - #9TK24W
STR-D560Z, 40, sony/str-d560z.pdf
FD8134V Security Camera - #8TM9SL
FD8134V, 146, vivotek/fd8134v.pdf
Oki Printer Manual (#WN8C1J)
page 8z, 2, oki/page-8z.pdf
Meade Telescope Manual (#4SB53P)
NG70-SM, 24, meade/ng70-sm.pdf
Magnavox Reference Book Game Videogames and the Entertainment Revolution Trigger Happy (#29NZRT)
Videogames and the Entertainment Revolution Trigger Happy, 433, magnavox/videogames-and-the-entertainment-revolution-trigger-happy.pdf
ATCOM User Manual: Rainbow1 (#TWCV7N)
Rainbow1, 12, atcom/rainbow1.pdf
Dell Guide Server VmWare ESX Server 2.12 Deployment (#66851T)
VmWare ESX Server 2.12 Deployment, 34, dell/vmware-esx-server-2-12-deployment.pdf
FM1000A Amplifier - #439856
FM1000A, 64, crown/fm1000a.pdf
Advantech Handbook: FPM-3191G (#KQ3XOT)
FPM-3191G, 40, advantech/fpm-3191g.pdf
LENCO Instruction: DVT-1932 (#3LY1KC)
DVT-1932, 1, lenco/dvt-1932.pdf
INSTAI ATIONINSTRUCTIONSCOMMERCIAL STACKED WASHER/DRYERGAS OR ELECTRICINSTRUCTIONSD'INSTALLATIONLAVEUSE/SECHEUSE SUPERPOSEESUSAGE COMMERCIAL/k GAZ OU t_LECTRIQUEINSTRUCCION.ESINSTALACIONLAVADORA/SECADORA COMERCIALESAPILADASA OASO ELt CTRICASTABLE OF CONTENTSPageStacked Washer/Dryer ...
Model & Doc Type: MLE20PRBZW1 120
NA1 www.aristonappliances.usUser guideContentsDescription, 2Important Safety Instructions, 3-4Your safety and that of your familyWarnings about installationTechnical detailsUnpacking, Installation, 5-6-7-8-9Unpacking and levellingRemove the shipping boltsWater and Electric connect ...
Model & Doc Type: AW 125 23
EX. RINSE103°MOTORSTARTBLK/REDREDBLK/HEATERTHERMOSTAT2 KCAUTION: DISCONNECT ELECTRIC CURRENT BEFORE SERVICING. LABELALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.VERIFY PROPER OPERATION AFTER SERVICING.THERMOSTATCONT ...
Model & Doc Type: GLGT1142CS1 1
1GBEnglish,1ContentsInstallation, 2-3Unpacking and levelling, 2Electric and water connections, 2-3The first wash cycle, 3Technical details, 3Washer-dryer description, 4-5Control panel, 4Leds, 5Starting and Programmes, 6Briefly: how to start a programme, 6Programme table, 6Personalisations, ...
Model & Doc Type: WIDL 106 12
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | LG | FWV796 TSE Series |
60 | 27/02 | ||
2 | Hobart | UW50 ML-27838 |
16 | 1.01 Mb | 15/10 | |
3 | LG | DLE2512W |
45 | 07/02 | ||
4 | Kenmore | 363.61542 |
60 | 21/02 | ||
5 | Siemens | WD15H542EU |
44 | 02/02 | ||
6 | Splendide | 2100XC |
2 | 16/01 | ||
7 | Asko | W6661 |
2 | 0.05 Mb | 26/12 | |
8 | Frigidaire | FAQG7011LB |
2 | 0.42 Mb | 23/01 | |
9 | Frigidaire | FEZ831CFS1 |
13 | 1.55 Mb | 08/11 | |
10 | Alliance Laundry Systems | SWD455C SVG |
50 | 21/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Vibe | LA4 |
8 | 2.22 Mb | 14.04.2024 | |
2 | Zanussi | MC 20 MB |
23 | 1.82 Mb | 01.04.2024 | |
3 | Sony | PMW-200 |
134 | 11.03.2024 | ||
4 | Melissa | 16190012 |
25 | 27.12.2023 | ||
5 | Chauvet | DJ Bank |
13 | 1.08 Mb | 05.10.2023 | |
6 | Generac Power Systems | 004917-5 |
48 | 6.24 Mb | 03.03.2024 | |
7 | Yamaha | R-9 |
20 | 2.49 Mb | 23.10.2023 | |
8 | Nice | EDSWG/A |
2 | 09.03.2024 | ||
9 | Visionhitech | VQ29SFHD2 |
2 | 04.03.2024 | ||
10 | OHAUS | Scout Pro |
40 | 25.03.2024 |