Text Version of HP D7171A - NetServer - LPr Adapter, Desktop Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 27 February 2024)


HP  219239  BACK SIDE  PN D9431-80204   6.181 X 11.811   DC 1682 ALA  SP  85/2400  OM
P/N: D9431-80204 
This information is subject to change without notice and is
provided without warranty.
Selected HP Accessories
For other tested accessories, download the Order Assistant from
the HP Web page.
Note that the embedded SCSI Controller and PCI Slot #3
share the same interrupt line. The operating system will
distinguish the interrupt source, but performance will be
adversely affected.
•
•
Check that the System Board is properly seated in the
I/O Board.
If an error code appears during boot, place the HP Network
Navigator CD in the CD-ROM drive, attempt the boot and
then press the ENTER key when the error code appears.
An explanation will appear on the screen.
•
On power-up, a beep error code message may appear
before the video display starts.  Refer to the list of Beep
Codes in Information Assistant on your LPr On-Line
Documentation CD.
•
Check LEDs at front and rear of system as shown in
panels at left.
•
Electrostatic Discharge  To avoid catastrophic or hidden
damage to components, wear a wrist strap and use a static-
dissipative work surface connected to the chassis when
handling components.  Use an antistatic service kit, such as
3M   8501/8502/8505 or equivalent.
®
©2000, Hewlett-Packard Company. All rights reserved.
System Troubleshooting
For additional information, see other side.
Audience Assumptions
This Service Reference Label is for trained service personnel.
Hewlett-Packard Company assumes you are qualified in the
servicing of computer equipment and trained in recognizing
hazards in products with hazardous energy levels.
Interrupt Sharing
HP NetServer LPr Service
Information
• Internet Web Page  http://www.hp.com/go/netserver
• Internet FTP  ftp://ftp.netserver.hp.com
• CompuServe Library  GO HPPC
• HP Navigator CD
Electronic Support Services
• HP-Authorized Reseller
• CompuServe Discussion Forum  GO HPPC
• US / Canada Phone Support  1-970-635-1000
• Europe Phone Support  (+31-20) 581-3330 (Netherlands)
HP has offices in over 100 countries.  Check your local telephone
directory.
Support Questions
Rear Panel LED Definitions:
Link
Activity
100 Mbps
Steady green when the LPr's network adapter and the network
switch are properly connected and receiving power.
Rate of green flashes reflects network traffic to/from LPr's network adapter. 
Steady green indicates support of 100 Mbps transfers.  Off for 10 Mbps transfers.
Power Inlet
Management Port
Network
Monitor
Keyboard
Mouse
Parallel Port
Serial Port A
Serial Port B
Ultra SCSI
PCI Slot #3
PCI Slot #2
PCI Slot #1
Link LED
Activity LED
100 Mbps LED
See LED
definitions below
Power
On/Off LED
Reset Switch Drive Activity LED
Drive Error
LED
Fan Failure
LED
Over-Temperature
LED
Reset
Power On/Off
Switch
Rear Panel
E
Control Panel
F
Space Requirements
System Dimensions
3.5"H x 17.6"W x 28"D
(8.9cm x 44.7cm x 71.1cm)
Rack Space
2 EIA units
Rack Clearance
None required
System Weight
40 lbs (88 kg)
Air Conditioning Requirements
Maximum Heat Output
1041 BTU/hour
Operating Temperature
41 to 95 degrees F
(5 to 35 degrees C)
Operating Humidity
20% to 80% RH
Power Requirements
Operating Current
100 VAC 5.3A
120 VAC 4.6A
200/208 VAC 3.2A
220/230 VAC 2.8A
Delayed Action Circuit Breaker
Recommendations
110/120     60Hz - NEMA AB1 Class 14B
220/240     50Hz - IEC Type C for 16A circuits
Leakage Current in Rack
15mA
In-Rush Current
25A
Voltage and Frequency
88 - 264VAC, 47-63Hz
Specifications
G
Control Panel LED Definitions:
Power On/Off
Drive Activity
Drive Error
Steady green shows system power ON.
Flashes green to show access over embedded SCSI controller.
Flashes red to indicate that one of the two drives in the hot-swap bays has failed and
must be replaced.  Remove front bezel to check drive LEDs.  Flashes yellow to predict
drive failure or to indicate that the drive is running out of space.  Use TopTools to
determine cause.
Fan Failure
Over-
Temperature
Flashes red when temperature is hazardous -- shut down and check for sources of over-
temperature.  Flashes yellow when temperature nears hazardous levels 
- 
check for
source of over-temperature.
Flashes red to indicate a fan failure 
- 
shut down gracefully and replace the fan.
Flashes yellow to indicate the start of a fan failure -- schedule shutdown and fan
replacement.
Memory
H
Mass Storage
I
Two hot-swap SCSI drive shelves support LVDS
low-profile SCSI devices.
•
Do not use HVD SCSI devices in the LPr.
•
Use single-ended SCSI devices on the SCSI bus
outside of the LPr.
•
Be certain any external SCSI cable ends with proper
termination and does not exceed 2.5 meters.
•
Use only HP DIMMs.
•
DIMMs may be installed in any combination in any
socket.
•
The LPr ships with 64MB and can support 1GB.
•





DOC-27b69181:

Recommended:
SRT 4304, 2504, 5100 - Cell Phone 725 KB, KW550

IdeaCentre B305, NUC8CY, 3270, TWR-MPC5125, Precision T3500, Inspiron 410
  • Ergo R8152.4GHz rechargeable wireless laser mouseprotectionHigh Tracking Performance&Built-in ChargerErgo R815 is the latest mouse from Genius that istechnologically brilliant. Its primary features are 2.4GHz RF cordless technology, 1600 and 800 dpiswitching sensor and a USB battery charger c ...

    Model & Doc Type: ERGO R815 3

  • 1Thin Client Virus Vulnerability AnalysisVirus vulnerabilities, encounters, and impact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Virus encounter vectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

    Model & Doc Type: Compaq t5720 12

  • iFireGL™ X2-256t FireGL™ X2-256 FireGL™ X1-128 FireGL™ Z1-128 User’s Guide P/N: 137-50015-40© Copyright 2004, by ATI Technologies Inc.All rights reserved. Reproduction of this manual, or parts thereof, in any form, without the express written permission of ATI Technologi ...

    Model & Doc Type: 100-505181 - FireGL 256 MB PCI-Express Card 61

  • White PaperJanuary 200011NH-0100A-WWENPrepared by:Multi-Vendor Solutions StorageProducts DivisionCompaq Computer CorporationContentsIntroduction................................. 3Servers and OperatingSystems....................................... 4Enterprise Backup SolutionComponents... ...

    Model & Doc Type: Aero 8000 18

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Lenovo
ThinkCentre M70a
11 14/12
2 HP
Pavilion Elite e9240f
35 07/02
3 Advantech
MICA-071
2 16/12
4 Moxa Technologies
V2201
10 22/02
5 Epson
PictureMate - Compact Photo Printer
1 0.6 Mb 13/01
6 IBM
L40 SX
120 07/11
7 Sony
VPCCA4E1E/D
164 02/03
8 HP
D5970A - NetServer - LCII
203 1.78 Mb 13/04
9 IBM
A60 Type 6833
58 05/12
10 Intel
BS-E098
131 16/04

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Samsung
RF263TE
32 30.01.2024
2 Samsung
HTEM45
59 22.03.2024
3 Siemens
Gigaset S450 IP
131 1.89 Mb 16.11.2023
4 Renault
GRAND SCENIC
29 5.49 Mb 28.01.2024
5 Makita
HM1200
5 24.03.2024
6 Olympus
E-400
4 09.02.2024
7 HW Group
HWg-SH4
48 29.02.2024
8 Optocore
DD32R-FX
26 22.01.2024
9 Scarlett
SC-4249
21 31.03.2024
10 Kidz Delight
Arthur's fun phonics
2 01.03.2024
Operating Impressions, Questions and Answers: