Lochinvar ARMOR 151 - 801 Service Manual

Service Manual for Lochinvar ARMOR 151 - 801 Water Heater (40 pages)

Specifications:

535/535049-armor_151__801.pdf file (28 Mar 2024)
  • Manufacturer: Lochinvar
  • Category of Device: Water Heater
  • Document: ARMOR 151 - 801, File Type: PDF Service Manual
  • Updated: 28-03-2024
  • Count of Pages: 40
Download ARMOR 151 - 801 Manual (40 pages)

Read PDF Document Online:

Data: UPD 28th March 2024

Lochinvar ARMOR 151 - 801 Water Heater PDF Service Manual (Updated: Thursday 28th of March 2024 09:55:49 PM)

Rating: 4.9 (rated by 22 users)

Compatible devices: A07H00123456, Armor AWH0400N, Solar Electric Water Heater, Lock Temp SJS060, WATER HEATERS, Power Fin PF-0502 (M9), Knight 81, MFH-I&S-02.

Recommended Documentation:

Text Version of Lochinvar ARMOR 151 - 801 Water Heater Manual (Summary of Contents)

(Ocr-Read of Lochinvar ARMOR 151 - 801 Document (Main Content), UPD: 28 March 2024)
  • 34, 3 Troubleshooting 34 Service Manual Table 3F (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface FAULT DESCRIPTION CORRECTIVE ACTION Outlet Temp High Outlet water temperature has exceeded the maximum outlet water temperature. …

  • 30, Service Manual 30 3 Troubleshooting Table 3F (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface FAULT DESCRIPTION CORRECTIVE ACTION No Flame Running (will require a manual reset once the condition has been corrected. Press th…

  • 16, Service Manual 16 1 Service F: Control modes BMS Thermostat Input (Active / Inactive) When controlling the water heater through the 0 - 10V BMS input or through ModBus, the water heater can be enabled one of two ways. With parameter F1 set to ACTIVE, the water heater will be enabled by clo…

  • 26, Service Manual 26 3 Troubleshooting Table 3B - Inlet System Sensor Resistance vs. Temperature Temperature °F Resistance Ω Temperature °F Resistance Ω 50 18,780 158 1,990 68 12,263 176 1,458 86 8,194 194 1,084 104 5,592 212 817 122 3,893 -- -- 140 2,760 -- -- Checking temperature sensors The…

  • 38, Lochinvar ARMOR 151 - 801 38 Model 501 Locate the throttle adjustment screw on top of the gas valve, see FIG. 3-4. Using a screwdriver, turn the screw a 1/4 turn counterclockwise to increase CO 2 levels or a 1/4 turn clockwise to decrease CO 2 levels. After one adjustment on the valve, follow the Combustion…

  • 37, Service Manual 37 3 Troubleshooting (continued) Gas valve adjustment procedure If adjustment of the gas valve is deemed necessary, use the following procedures: (Note: The procedures in this section are model specific.) Models 151 - 286 Locate the throttle adjustment screw on the side of the …

DOC-7533f611:

Recommended:
Stealthbox SB-GM-CAM6G/12TW3, Good Grips, 572.247202, GeoSafari Laptop Jr.

ECO110, Edel AIR Series, MonoWave Series, 200EH1-14, OFS25, SMART 3.5
  • - 1 - 17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 * (800) 582-8423 Fax: (413) 247-3369 E-mail: [email protected] SB 150, SB 200 Glass Lined Indirectly Fired Water Heaters With Single Heat Exchanger INSTALLATION AND OPERATING INSTRUCTIONS SB150 (40 gallon ...

    Model & Doc Type: SB 150 9

  • GEAppliances.com-(:3rYL)L_UIii-(:3L_"p..0I,.9Important Safety Information ...2-4Operating InstructionsControl Panel ..........................................5Powering Unit .........................................6Temperature Setting ............................7OpemtionQl Modes .......... ...

    Model & Doc Type: Appliances Geospring GEH50DEEDXX 72

  • PowerStream ProGARANTÍA LIMITADA DE 10 AÑOS (continuación de la Página 11)3. Verificación de la fecha de instalación original: cuando el propietario no puede verificar odocumentar la fecha de instalación original, el período de garantía se inicia en la fecha defabricación ...

    Model & Doc Type: RP17PT 12

  • Operation and Installation Manual WATER HEATERS FOR SOLAR SYSTEMS OKC 200 NTRR/SOL OKC 250 NTRR/SOL OKC 300 NTRR/SOL OKC 400 NTR/SOL OKC 500 NTR/SOL OKC 400 NTRR/SOL OKC 500 NTRR/SOL Družstevní závody Dražice – strojírna s.r.o. (Works Cooperative - Dražice – ...

    Model & Doc Type: OKC 200 NTRR/SOL 12

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 EHC
NDIR120L
18 30/12
2 TLV
SteamAqua SQ-C01
43 05/03
3 SPX FLOW
Johnson Pump AquaH
28 19/12
4 Baxi
Solo HE a series
12 0.26 Mb 14/10
5 Rheem
RUTG 64DV
130 11/03
6 Vaillant
uniSTOR VIH GB /3 BES Series
24 08/11
7 Kingspan
AUXD120
28 08/12
8 Heatrae Sadia
Aquatap
4 07/10
9 Bosch
AquaStar 38B LP
16 26/11
10 Slant/Fin
VICTORY VSPH SERIES
24 1.31 Mb 23/02

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Net Optics
10 GigaBit Media Converter Tap
14 18.03.2024
2 Sanyo
PLC-XP40L
44 1.22 Mb 22.12.2023
3 NetGenie
Home
79 25.10.2023
4 Panasonic
KX-TG5230
84 5.25 Mb 07.11.2023
5 EDOBE
XDOM RMA - PRODUCTSHEET
1 0.25 Mb 02.11.2023
6 Ansonic
FA 690 NF
32 24.01.2024
7 Miller
Big Blue 400 CX CE
82 22.03.2024
8 Philips
37PF5312
3 23.03.2024
9 Toshiba
32AF53
48 6.71 Mb 19.11.2023
10 Welbilt
ABM-100-3
16 3.41 Mb 03.04.2024
Operating Impressions, Questions and Answers: