Specifications:537/537040-asr45681242.pdf file (09 Apr 2024)
|
LST ASR-45681-242 Smoke Alarm PDF Specification Sheet (Updated: Tuesday 9th of April 2024 08:40:37 PM)
Rating: 4.5 (rated by 62 users)
Compatible devices: ABF216-1, FC600/O, HT-11006, M400DKMB-AS, OH-13001, Vds 249003, Vds BC216-1, FC600/TMAX/78.
Recommended Documentation:
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVED ASR-45681-242_DBL_LST_EN_0804.PDF • PAGE 1 ABuilding Safety. Building Security. Detector Base XP95/Discovery ASR-45681-242 with Relay Output Description Specifi cations The Detector Relay Base ASR-45681-242 accommoda- tes automatic fi re detectors Series XP95 and Discovery for use in ADM loops with Apollo/Discovery protocol. Due to its robust multi-wire screw terminals, the detec- tors can be wired with ease, thus achieving a secure and durable connection. In addition, a relay output with a dry change-over contact is integrated into the detector base. The relay output is activated through the alarm activation of the inserted detector and remains active until the alarm is reset on the fi re detection control panel. The address is selected by means of a code card in the base. Therefore the detector can be changed without additional tools. The base has been designed for surface mounting in dry rooms. For special applications a range of acces- sories (for moist room, false ceiling or fl ush installation) is available. A mechanical theft protection of the detector can optionally be activated at the detector base. • Suitable for automatic detectors in ADM loop technology with Apollo/Discovery protocol • Relay output with dry change-over contact • Screw terminals for secure connection of multiple wires • Easy addressing by means of code card • Mechanical theft protection can be activated Operating voltage Supply through loop voltage Current consumption max. 1µA (quiescent), 40µA (active) Contact rating 1A/30VDC Ambient temperature -20°C to +70°C Relative humidity 10 – 95% (no condensation) Dimensions ø × H 100 × 24 (mm) Colour white Weight 100g Order number 246037 Order name Detector Relay Base/Anal./XP95/Disc/Apo ASR-45681-242
Mettler Toledo Document: PL202E (#XN6XM4)
PL202E, 76, mettler-toledo/pl202e.pdf
Security Camera Handbook #1IN72V
SCC-B2315P, 162, samsung/scc-b2315p.pdf
Amplifier BODA 86A-30P User Manual, #2Y68G2
BODA 86A-30P, 4, blonder-tongue/boda-86a-30p.pdf
Handbook (C.A 6454, #783KBQ)
C.A 6454, 183, chauvin-arnoux/ca-6454.pdf
Guide (5004, #3J1O27)
5004, 2, adtran/5004.pdf
#V3OZ79: NOD32 V 2.7 - Document
NOD32 V 2.7 -, 24, eset/nod32-v-2-7.pdf
Planet IP Camera Manual (#NJ9H1Q)
ICA-3350V, 16, planet/ica-3350v.pdf
User Manual (SW-3, #5CH3Y9)
SW-3, 14, yamaha/sw-3.pdf
BC-91305 Battery Charger - #BYT88X
BC-91305, 13, associated-equipment/bc-91305.pdf
Wood stove STANFORD 9 User Guide, #857FSJ
STANFORD 9, 21, nestor-martin/stanford-9.pdf
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDM221E_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.ModuleM221EDescriptionThe addressa ...
Model & Doc Type: M221E 2
Lithium (non-replaceable sealed in) Battery-Operated Photoelectric Smoke Alarm with wireless RF Interlink and HUSH® Control You do NOT need a home wi-fi system to use these units. Multiple wireless units create their own independent wireless RF interlink network.Smoke Alarm with RF Interli ...
Model & Doc Type: LIF10YPEW 26
JABLOTRON ALARMS a.s.Pod Skalkou 4567/33 46601 Jablonec n. NisouCzech Republic www.jablotron.com|||The JA-110ST Bus combined smoke and heat detector The JA-110ST Bus combined smoke and heat detector 1 / 2 MLW51612The JA-110ST is a component of the JABLOTRON JA-100 system. It is used to detect fi ...
Model & Doc Type: JA-110ST 2
SR-730 PG2 is a self-powered wireless two-way outdoor siren (IP55) that provides the perfect security solution for home owners with PowerMaster® intrusion alarm systems, looking for an external siren that is both affordable and easy to install. SR-730 PG2 Two-way Wireless Outdoor Siren � ...
Model & Doc Type: SR-730 PG2 1
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Radionics | D285 |
2 | 29/11 | ||
2 | Faraday | MPC-6000 |
56 | 28/02 | ||
3 | Pittway | System Sensor B524BI |
4 | 22/02 | ||
4 | Notifier | AFP-400 |
48 | 12/10 | ||
5 | usi | MI106S |
11 | 30/11 | ||
6 | Apollo | XPERT 8 |
2 | 23/01 | ||
7 | Tyco | MR601TEx |
7 | 26/10 | ||
8 | Kidde | 1296 |
2 | 05/12 | ||
9 | Thorn security | MR300 |
7 | 04/12 | ||
10 | SILENT KNIGHT | INTELLIKNIGHT 5820XL |
1 | 21/04 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | BellSouth | GH9492 |
57 | 01.12.2023 | ||
2 | Sanyo | CLT-D6620 |
42 | 6.99 Mb | 26.12.2023 | |
3 | Whirlpool | SF375PEW |
32 | 13.03.2024 | ||
4 | Compuprint | L03 |
38 | 4.15 Mb | 11.11.2023 | |
5 | Shure | Conference Phone |
124 | 3.54 Mb | 09.04.2024 | |
6 | Baumatic | BHI655 |
36 | 18.01.2024 | ||
7 | Crosley | CR48 |
5 | 0.05 Mb | 21.01.2024 | |
8 | Wolf cinema | SDC-12 |
81 | 10.01.2024 | ||
9 | Volkswagen | 2013 GTI |
11 | 8.18 Mb | 30.12.2023 | |
10 | Lenovo | ThinkCentre M32 |
96 | 11.11.2023 |