LST B524IEFT-1 Manual, Specification Sheet

Manual, Specification Sheet for LST B524IEFT-1 Smoke Alarm (1 pages)

Specifications:

537/537043-b524ieft1.pdf file (08 Dec 2023)
  • Manufacturer: LST
  • Category of Device: Smoke Alarm
  • Document: B524IEFT-1, File Type: PDF Specification Sheet
  • Updated: 08-12-2023
  • Count of Pages: 1
Download B524IEFT-1 Manual (1 pages)

Read PDF Document Online:

Data: UPD 8th December 2023

LST B524IEFT-1 Smoke Alarm PDF Specification Sheet (Updated: Friday 8th of December 2023 11:49:13 PM)

Rating: 4.6 (rated by 22 users)

Compatible devices: 1151EIS, ASA-45681-210, 2351E, Series 200, 6500R, FWI016-1, M510E-4-20, SIM016-3.

Recommended Documentation:

Text Version of LST B524IEFT-1 Smoke Alarm Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 08 December 2023)


© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
B524IEFT-1_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.

Isolator Detector Base

B524IEFT-1

Description
Specifi cations
The Isolator Detector Base B524IEFT-1 is designed to 
accommodate intelligent fi re detectors Series 200 and 
500  for  use  in  ADM  loops  with  System  Sensor/200 
protocol.
A dual-isolator unit is integrated into the detector base, 
which reliably disconnects the loop in case of a short 
circuit. With the dual design, the input side or the out-
put  side  isolator  –  depending  on  the  location  of  the 
short  circuit  – interrupts  the connection to  the  faulty 
loop segment. Therefore the detector remains in ope-
ration.
Due to its robust multi-wire screw terminals, the detec-
tors can be wired with ease, thus achieving a secure 
and durable connection. The base also provides a pos-
sibility for the easy connection of remote indicators.
The  base  is  designed  for  surface  mounting  in  dry 
rooms.  For  special  applications  a  range  of  accesso-
ries (for moist room, false ceiling or fl ush installation) 
is available.
A  mechanical  theft  protection  of  the  detector  can 
 optionally be activated at the detector base.
•   Suitable for automatic detectors 
in ADM loop technology with 
System Sensor/200 protocol
•   Dual-isolator unit
•   Screw terminals for secure 
connection of multiple wires
•   Terminals for connection of remote 
indicator
•   Mechanical theft protection can be 
activated
Current consumption  max. 100µA (quiescent)
Ambient temperature  -30°C to +70°C
Relative humidity  0 – 93% (no condensation)
Dimensions ø × H  102 × 26 (mm)
Colour   cream
Weight  70g
Approval  VdS G200100
Order number  246013
Order name  Isolator Detector Base/Anal./500/200/SS B524IEFT-1





DOC-9addb8f2:

Recommended:
L32K3, Classic 502-DST Series, LT600-DR/D/L, BT-390

ZX1e, Ei3105RF, VLF-500, Vds BC216-1, BQ2050, MS-5UD Series
  • ImporterELRO Europe | www.elro.euPostbus 9607 - Box E8001006 GC Amsterdam The NetherlandsManufacturer:Siterwell Electronics CO., Limited No.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, China 315034 Home is not a place, it’s a feelingFS1105P25%93%40 m²0°C40° ...

    Model & Doc Type: FS1105P 2

  • 120V AC Wire-In Smoke Alarm Slide Load Front Battery Door, Alkaline Battery, 10 Yr WarrantyModel i5000 DescriptionThe Kidde i5000 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V alkaline battery backup. This alarm uses ionization sensing technology. Ionizati ...

    Model & Doc Type: I5000 2

  • 1Thank you for purchasing a Kidde Fyrnetics alarm. Please read through our guide in full. It should be retained for future reference.Kidde Fyrnetics recommends for maximum protection that both ionisation andphoto-electric (optical) smoke alarms be installed. Ionisation sensing alarms ...

    Model & Doc Type: 123I 8

  • Doc No. FM0467 issue F Page 1 COMMAKEWe declare this product complies with the relevant UK legislation on condition that it is used in the manner intended, and in accordance with the current installation standards and/or the manufacturer's recommendations. A copy of the fu ...

    Model & Doc Type: Aidcall 5

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 SensingTEK
SDZ2100 WSN Smoke
2 03/12
2 Micro Direct
SmokeCheck
26 18/11
3 Brooks
RFS1 V2
46 14/03
4 Aparton
ASD-10
2 25/01
5 Honeywell
FCI 2451 Series
2 08/11
6 System Sensor
1012 Ionization
4 06/04
7 ESE
BRK First Alert SA511B
3 07/10
8 System Sensor
2351B
2 06/10
9 Apollo
Smoke Detector XP95
2 06/12
10 SST
S250
10 26/11

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Electrolux
LAVATHERM 56840L
28 2.61 Mb 04.12.2023
2 Electro-Voice
S12-2A
4 0.84 Mb 21.12.2023
3 Datexx
DRC-700
4 1.2 Mb 12.12.2023
4 Aastra
M760E
98 3.08 Mb 11.12.2023
5 Metra Electronics
99-7500
4 07.11.2023
6 Simplicity
461
4 0.09 Mb 17.12.2023
7 SNOWJOE
ASHJ202E
16 06.03.2024
8 Panasonic
SR-W15FP
16 0.71 Mb 14.12.2023
9 Yamaha
Big Bear YFM350UBL
170 16.02.2024
10 Samson
MIXPAD
40 0.28 Mb 27.12.2023
Operating Impressions, Questions and Answers: