Specifications:537/537077-hfm32202.pdf file (10 Dec 2023)
|
LST HFM/3/22/02 Smoke Alarm PDF Specification Sheet (Updated: Sunday 10th of December 2023 07:50:31 PM)
Rating: 4.3 (rated by 62 users)
Compatible devices: MM-55000-833, M221E, 5351TE, M400DKMB-AS, ECO1003, FSK700-2SX, GD-55000-122, AO-58000-600.
Recommended Documentation:
0786–CPD–20361 © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVED HFM-ADM_DBL_LST_EN_0819.PDF • PAGE 1 ABuilding Safety. Building Security. Manual Call Point HFM/3/22/02 Description Specifi cations The manual call point according to EN 54-11/B is de- signed for use in ADM loops with System Sensor/200 protocol and is accommodated in a robust die-cast aluminium case. In comparison with plastic cases, the aluminium case proves to be of advantage even after years of use, thanks to its resistance to environmental impact: It is virtually unbreakable, form stable and hard- ly changes its colour in sunlight. A built-in LED optically indicates the activated condition of the manual call point. The detector address can be set by means of a push-button and the entered address is displayed by an LED. The detector is provided with a dual-isolator, which disconnects the adjacent loop ele- ments fast and safely in case of a short circuit. The hinged door can be opened up to an angle of 180° and it is provided with a replaceable pane of glass. If the detector has been activated, an integrated locking device prevents the closing of the door. Custom versions with different colours, designs, func- tions and internal wirings are available on inquiry. By means of the optional Protection Kit HFM/HM-ZS-IP54, the protection class can be increased to IP54. • ADM loop technology with System Sensor/200 protocol • Robust die-cast aluminium case • LED indicates activation • Integrated dual-isolator • Operating instructions by means of standardised symbols • Increase of protection class to IP54 by using optional protection kit Operating voltage Supply through loop voltage Current consumption 300µA (quiescent) Ambient temperature -20°C to +60°C (continuous operation) -25°C to +70°C (max. 12 hours) Protection class IP43 Dimensions W × H × D 125 × 125 × 34 (mm) Colour fl ame red, RAL 3000 Weight 400g Approval VdS G202035 0786-CPD-20361 Order number 245362 Order name Manual Call Point/Red/Anal./SS HFM/3/22/02
#V5LINV: FWW7003 Tutorial
FWW7003, 1, anvil/fww7003.pdf
VFR750F Motorcycle - #E199C1
VFR750F, 102, honda/vfr750f.pdf
#S3W38O: PERFORMANCEEXPERT DSA 500 RT Guidance
PERFORMANCEEXPERT DSA 500 RT, 46, focal/performanceexpert-dsa-500-rt.pdf
Toyota Automobile Manual (#4ZU75X)
T100, 64, toyota/t100.pdf
Hotpoint Guidance: HDA3520 (#2RZ96C)
HDA3520, 32, hotpoint/hda3520.pdf
Videotec Guidance Thermal cameras MAXIMUS MVXT (#V343HZ)
MAXIMUS MVXT, 270, videotec/maximus-mvxt.pdf
Car Stereo System LVT1055-001A Handbook, #ZO5M6V
LVT1055-001A, 80, jvc/lvt1055-001a.pdf
Peavey Tutorial Processor MIDI Streamer (#5SCOMU)
MIDI Streamer, 27, peavey/midi-streamer.pdf
Philips Stereo System Manual (#9318Q7)
FW-C399/21M, 2, philips/fw-c399-21m.pdf
Repeater Guide #644L97
1750E, 38, fritz/1750e.pdf
1 Smoke Detector Series SD-29-SC-AC Series SD-29-SC-AC Series is a mini-sized wireless smoke detector with built-in PIR motion sensor and heat detection capability. Designed to protect your family against potential fire hazards, the Smoke detector is also capable of dete ...
Model & Doc Type: SD-29-SC-AC Series 4
MODEL MDSCN103CN,MODEL MDSCN103LCNIoPHIC® SMOKE & FIRE ALARM,CARBON MONOXIDE ALARM &NATURAL GAS ALARM120VAC 60 Hz 100 mA Max.MODEL MDSCN111CN,MODEL MDSCN111LCNIoPHIC® SMOKE & FIRE ALARM,CARBON MONOXIDE ALARM &NATURAL GAS ALARM120VAC 60 Hz 100 mA Max.THANK YOU fo ...
Model & Doc Type: UNIVERSAL MDSCN111CN 18
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDHT-11002_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Thermal Max DetectorHT-11002• ...
Model & Doc Type: HT-11002 1
700 SERIESPHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATIONSMOKE ALARMS AC POWERED, 120V, 60Hz or 220V, 50HzInstallation Instructions - Owner's Information INTRODUCTION 700 SERIESThe 713 Series Smoke Alarm is a Photoelectric TypeAlarm for use as an evacuation device in residential application ...
Model & Doc Type: 700 SERIES 6
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Bellman & Symfon | BE1481 |
12 | 02/02 | ||
2 | pyrexx | PX-1 |
60 | 19/01 | ||
3 | Ei Electronics | Ei 3100RF |
20 | 26/10 | ||
4 | Radionics | D8024 |
18 | 30/10 | ||
5 | UniPOS | FD 7130 |
2 | 14/01 | ||
6 | Hama | GS 506 |
12 | 4.99 Mb | 14/09 | |
7 | System Sensor | DNRHS |
8 | 08/12 | ||
8 | Ei Electronics | EI 159 |
1 | 0.03 Mb | 22/02 | |
9 | UltraFire | UBS1 |
18 | 21/11 | ||
10 | Wheelock | MT-12-LS |
9 | 0.33 Mb | 04/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Monacor | HDTVI-100 CON |
4 | 14.03.2024 | ||
2 | NEC | SV-8100 |
86 | 20.01.2024 | ||
3 | Toshiba | RAS-13UKHP-ES3 |
80 | 22.01.2024 | ||
4 | Husqvarna | CTH155 |
88 | 23.09.2023 | ||
5 | Perfect Aire | PADP50 |
12 | 27.11.2023 | ||
6 | VanAccess | IP0120 |
51 | 29.01.2024 | ||
7 | HP | Pro 3125 - Minitower PC |
4 | 0.66 Mb | 17.02.2024 | |
8 | Stiga | MULTICLIP 11-8186-99 |
2 | 0.07 Mb | 18.11.2023 | |
9 | KICK STAR | KICK STAR WALL |
2 | 16.11.2023 | ||
10 | clage | DSX SERVOTRONIC MPS |
13 | 24.01.2024 |