User's Manual
GT15-J71E71-100 
Thank you for purchasing the GOT1000 Series.
GT15 Ethernet communication unit
Prior to use, please read both this manual and detailed 
manual thoroughly to fully understand the product.
MODEL GT15-J71E71-100-U
MODEL
CODE
1D7M29
IB(NA)-0800314-C(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Note that the  CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
Indicates that incorrect handling may cause 
hazardous conditions, resulting in death or 
severe injury.
Indicates that incorrect handling may cause 
hazardous conditions, resulting in medium or 
slight personal injury 
or physical damage.
DANGER
     CAUTION
     
[DESIGN PRECAUTIONS]
[INSTALLATION PRECAUTIONS]
[WIRING PRECAUTIONS]
[STARTUP AND MAINTENANCE PRECAUTIONS]
z Do not bunch the control wires or communication cables with 
the main circuit or power wires, or lay them close to each other. 
As a guide, separate the lines by a distance of at least 100 mm 
(3.94 inch) otherwise malfunctions may occur due to noise.
z Be sure to shut off all phases of the external power supply used 
by the system before mounting or removing this unit to/from the 
GOT.
Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always 
shut off GOT power and PLC CPU power externally in all 
phases.Not doing so can cause a malfunction.
z Use this unit in the environment given in the general 
specifications of the GT15 User's Manual.Not doing so can 
cause an electric shock, fire, malfunction or product damage or 
deterioration.
z When installing this unit to the GOT, fit it to the connection 
interface of the GOT and tighten the mounting screws in the 
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to 
screw or unit damage.
z Be sure to shut off all phases of the external power supply used 
by the system before wiring.
Failure to do so may result in an electric shock, product damage 
or malfunctions.
z Use crimp-contact, pressure-displacement or soldering to wire 
the connectors for external connections properly using the 
manufacturer-specified tools.
If the connection is incomplete, it may cause the module to short 
circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely.
z Always secure the cables connected to the unit, e.g. run them in 
conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling, 
moved or accidentally pulled cables or can cause a malfunction 
due to a cable contact fault.
z Before starting cleaning, always shut off GOT power externally 
in all phases. Not doing so can cause a unit failure or 
malfunction.
DANGER
DANGER
CAUTION
DANGER
CAUTION
DANGER
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For relevant manuals, refer to the PDF manual stored within the 
drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
When incorporating the Mitsubishi GOT into other machinery or 
equipment and keeping compliance with the EMC and low voltage 
directives, refer to Chapter 4, "EMC Directives and Low Voltage 
Directives" of the manual (GT15 General Description) included 
with the GOT used.
The CE logo is printed on the rating plate of the GOT, indicating 
compliance with the EMC and low voltage directives.
By making this product conform to the EMC directive and low 
voltage instruction,it is not necessary to make those steps 
individually.
z Do not disassemble or modify any unit. 
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this 
unit directly.
Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire 
offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable 
connected to the unit. Doing so can cause unit or cable damage 
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the 
electricity charged in the body, etc., before touching the unit. 
Failure to do so may cause a failure or malfunctions of the unit.
z Dispose of this product as industrial waste.
z Make sure to transport the GOT main unit and/or relevant unit(s) 
in the manner they will not be exposed to the impact exceeding 
the impact resistance described in the general specifications of 
the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail. 
Check if the unit operates correctly after transportation.
Detailed Manual
Manual name
Manual Number
(Type code)
GT15 User's Manual
(Option)
SH-080528ENG
(1D7M23)
GOT1000 Series Connection Manual
(Option)
SH-080532ENG
(1D7M26)
Relevant Manuals
CAUTION
CAUTION
CAUTION
1. Overview
This User's Manual describes the GT15 Ethernet 
communication unit.
The GT15-J71E71-100 is required when performing Ethernet 
connection or Gateway function with GOT.
After unpacking the box of GT15-J71E71-100, please check if  
the following items are contained.
2. Specifications
2.1 Performance Specifications
The performance specifications of the Ethernet communication 
unit are indicated below.
Refer to the used GT15 User's Manual for the general 
specifications of the Ethernet communication unit.
*1 This depends on the specifications of the Ethernet network sys-
tem to which the GOT is connected.
For the details, refer to the manual of Ethernet module of con-
nected PLC.
*2 If multiple network equipments (including GOT) are connected
within a segment, the network load would increase.
In such condition, the communication performance between GOT
and PLC may be declined.
The decline of the communication performance may be improved
by the following measures.
• Using switching hubs.
• Reducing the number of monitoring devices of the GOT.
Product name Model name Quantity
Ethernet communication unit GT15-J71E71-100 1
Mounting screw set (2 pieces 
of screw,2 pieces of label)
-1
For information concerning necessary OS in case of using GT15-
J71E71-100,refer to GOT 1000 Series Connection Manual.
Item Specification
Transmission 
specifications
Data transfer method 10BASE-T 100BASE-TX
Transmission 
method
Base band Base band
Maximum node to 
mode distance
200m 200m
Maximum segment 
length
100m 100m
Maximum number of 
cascade connection
4 steps 2 steps
Number of units mounted to GOT
Only 1 unit can be mounted 
to the extension unit 
interface.
Connecting 
condition
Number of GOTs 
connected
128 (Recommend 16 or 
less)*1*2
GOT placing 
distance
100m*1
Internal current consumption(DC5V) 0.22A
Weight 0.09kg
2.2 Specifications of the related devices
Use the connection cable and the hub which meet the 
IEEE802.3 10BASE-T/100BASE-TX standard.
3. Name of the Parts
Item
Specifications
10BASE-T 100BASE-TX
Cable
Non-shielded twisted pair 
wire (UTP cable)
(category3(4, 5)) 
Shielded twisted pair wire
(STP cable)
(category5)
Connector RJ45jack RJ45jack
Hub 10Mbps hub 100Mbps hub
No. Name Description
1) Mounting screw
Mounting screws fixed with the 
front communication unit or GOT.
2) Interface connector
Connector connected to the front 
communication unit or GOT.
3) Extension connector
Connector with which the back 
communication unit is fixed.
4) Ethernet connector
Connector to which Ethernet 
cable is connected.
5) 100M LED
It lights up during 100 Mbps 
transmission.
6) SD/RD LED
It blinks during data sending/
receiving.
7) Rating plate -
1)
7)
3)
2)
6)
4)
5)
4.  Installation Procedure
(1) Power off the GOT.
(2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along the groove 
of the GOT case.
(4) Fasten the Ethernet communication unit by tightening 
its mounting screws (2 places) with tightening torque 
0.36 to 0.48 N•m.
(5) When mounting an Ethernet communication unit on 
the outer layer, remove the connector cover and the 
seal.
When not mounting any communication unit on the 
outer layer, stick accessory labels on the top of 
mounting screws (2 places) to cover the top of them 
in order to avoid receiving electrostatic.
Keep the connector cover fixed.
Keep the seal stuck as it is.
Seal
A

ccessory labels
Connector cover
5. External Dimensions
Dimensions of X when mounted to the GOT.
Unit: mm (inch)
Point
(1)  Grounding work for the 10BASE-T and 100BASE-TX requires 
appropriate safety measures.
Consult professionals for work details including terminal of 
connection cables and other plant work such as laying of main 
cables.
(2)  If you remove the Ethernet unit, detach it from specified 
direction (shown PULL) so as not to break a connector.
8.4” 23 (0.91)
10.4”, 12.1”, 15” 21 (0.83)
Ethernet is a registered trademark of Xerox Corporation, U.S.
Other business or product names mentioned herein are a 
trademark or registered trademark of each company.
2.5
(0.10)
21 
(0.83)
3 (0.12)
63 (2.48) GOT main unit
0.5
(0.02
)

98 (3.89)
112 (4.41)
0.4
7
(0.28)
(0.31)
8
30.5 (1.2)
21.5 (0.85)
X
(0.02)
Warranty
Mitsubishi will not be held liable for damage caused by factors found 
not to be the cause of Mitsubishi; machine damage or lost profits 
caused by faults in the Mitsubishi products; damage, secondary 
damage, accident compensation caused by special factors 
unpredictable by Mitsubishi; damages to products other than 
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for 
general industries, and has not been designed or manufactured to 
be incorporated in a device or system used in purposes related to 
human life. 
• Before using the product for special purposes such as nuclear 
power, electric power, aerospace, medicine or passenger 
movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. 
However, when installing the product where major accidents or 
losses could occur if the product fails, install appropriate backup or 
failsafe functions in the system.
C

ountry/Region Sales office/Tel
U.S.A  Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
Brazil   MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar 
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
G

ermany   Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
U.K   Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Italy   Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
S

pain   Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France   Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
S

outh Africa  Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Hong Kong  Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
C

hina   Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
T

aiwan   Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, 
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea   HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong 
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
S

ingapore   Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
T

hailand   F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3  
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
Indonesia   P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan 
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
India   Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI, 
PUNE-411026, India
Tel : +91-20-712-2807
A

ustralia   Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN 
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry 
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.




DOC-dcdcfa65:

Recommended:
F100X, D7500, X782, PC-300

DM/N1200-4E1-cPCI, D1392602, PS9000, APG001Z, WG602v3 - Wireless Access Point, EZ Connect SMCHPAVH-ETH
  • PRODUCT DATASPA400Internet Telephony GatewayModel No.Advanced Multi-Port PSTN Gateway Solution for the Linksys Voice SystemIntegrated Voicemail Application Server with up to 32 Voicemail AccountsPerfectly Suited to Connect up to 4 Analog LinesFunctions as an Analog Line Gateway for a ...

    Model & Doc Type: SPA400 4

  • E6581542① TOSVERT VF-PS1 series APOGEE® FLN option unit Function Manual APG001Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of APOGEE® FLN option unit. 2. Read this manual before installing or operatin ...

    Model & Doc Type: APG001Z 28

  • Schottky Barrier Diodes (SBD)1Publication date: April 2004 SKH00087CEDMA3X787 (MA787)Silicon epitaxial planar typeFor super high speed switchingFor small current rectification■ Features• Forward current (Average) IF(AV) = 100 mA rectification ispossible• Optimum for high frequency re ...

    Model & Doc Type: MA3X787 (MA787) 3

  • Dialogic® DM/N1200-4E1-cPCI Digital Telephony Interface Board Quick Install Card for CompactPCI Part Number 64-0075-02 Copyright © 2003-2007 Dialogic Corporation. All Rights Reserved. Before You Begin Protecting the Board from Damage CAUTION: All computer boards are sensitive to elect ...

    Model & Doc Type: DM/N1200-4E1-cPCI 2

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 EAW
CobraNet CM-1
1 0.3 Mb 30/12
2 AMX
AXC-INP8
1 0.06 Mb 16/11
3 Texas Instruments
Technology for Innovators 4Q 2006
49 22/01
4 aqprox!
appPCI1000V2
40 03/04
5 Supermicro
AOC-A25G-b2S
29 15/02
6 VOIspeed
V-6017
22 02/03
7 ZyXEL Communications
NXC-8160
205 5.83 Mb 20/10
8 Zhone
Copper-Based Ethernet
8 0.98 Mb 01/03
9 HP
Compaq NC4000
44 31/01
10 BOSER Technology
Industrial Single Board Computer HS-6038
86 3.16 Mb 08/11

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 JohnsonSuisse
Gemelli JBTG2150
4 22.10.2023
2 Beko
BFR630DX
31 16.10.2023
3 Viking
R-6S
49 05.04.2024
4 LG
WF-HX150V
48 19.03.2024
5 HydroTools
8940H
6 07.11.2023
6 BenQ
Joybee 120
74 10.02.2024
7 Polaroid
PDC 3350
63 05.03.2024
8 Canon
Power Shot A400
142 1.84 Mb 10.12.2023
9 Elsner
KNX B4-UP
16 13.03.2024
10 Bionizer
Eco - Oxidizer
16 18.02.2024
Operating Impressions, Questions and Answers: