Specifications:558/558955-gt15_users_manual.pdf file (12 Jan 2024)
|
Mitsubishi GT15 Network Card PDF Operation & User’s Manual (Updated: Friday 12th of January 2024 04:00:05 PM)
Rating: 4.2 (rated by 43 users)
Compatible devices: FX2N, R100, Q Series, A8GT-50KBF, DS907x SIP, A101, FX2NC-ENET-ADP, PZ-41SLB-E.
Recommended Documentation:
User's Manual GT15-J71E71-100 Thank you for purchasing the GOT1000 Series. GT15 Ethernet communication unit Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product. MODEL GT15-J71E71-100-U MODEL CODE 1D7M29 IB(NA)-0800314-C(0507)MEE zSAFETY PRECAUTIONSz (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod- uct. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION". Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are impor- tant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. DANGER CAUTION [DESIGN PRECAUTIONS] [INSTALLATION PRECAUTIONS] [WIRING PRECAUTIONS] [STARTUP AND MAINTENANCE PRECAUTIONS] z Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100 mm (3.94 inch) otherwise malfunctions may occur due to noise. z Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction. z Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction. z Use this unit in the environment given in the general specifications of the GT15 User's Manual.Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration. z When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage. z Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions. z Use crimp-contact, pressure-displacement or soldering to wire the connectors for external connections properly using the manufacturer-specified tools. If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction. z Connect the connectors to the unit securely. z Always secure the cables connected to the unit, e.g. run them in conduits or clamp them. Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault. z Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction. DANGER DANGER CAUTION DANGER CAUTION DANGER [DISPOSAL PRECAUTIONS] [TRANSPORTATION PRECAUTIONS] Manuals The following shows manuals relevant to this product. For relevant manuals, refer to the PDF manual stored within the drawing software used. © 2005 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives, refer to Chapter 4, "EMC Directives and Low Voltage Directives" of the manual (GT15 General Description) included with the GOT used. The CE logo is printed on the rating plate of the GOT, indicating compliance with the EMC and low voltage directives. By making this product conform to the EMC directive and low voltage instruction,it is not necessary to make those steps individually. z Do not disassemble or modify any unit. This will cause failure, malfunction, injuries, or fire. z Do not touch the conductive areas and electronic parts of this unit directly. Doing so can cause a unit malfunction or failure. z Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit. Not doing so can cause a fire, failure or malfunction. z Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault. z Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit. z Dispose of this product as industrial waste. z Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User's Manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation. Detailed Manual Manual name Manual Number (Type code) GT15 User's Manual (Option) SH-080528ENG (1D7M23) GOT1000 Series Connection Manual (Option) SH-080532ENG (1D7M26) Relevant Manuals CAUTION CAUTION CAUTION 1. Overview This User's Manual describes the GT15 Ethernet communication unit. The GT15-J71E71-100 is required when performing Ethernet connection or Gateway function with GOT. After unpacking the box of GT15-J71E71-100, please check if the following items are contained. 2. Specifications 2.1 Performance Specifications The performance specifications of the Ethernet communication unit are indicated below. Refer to the used GT15 User's Manual for the general specifications of the Ethernet communication unit. *1 This depends on the specifications of the Ethernet network sys- tem to which the GOT is connected. For the details, refer to the manual of Ethernet module of con- nected PLC. *2 If multiple network equipments (including GOT) are connected within a segment, the network load would increase. In such condition, the communication performance between GOT and PLC may be declined. The decline of the communication performance may be improved by the following measures. • Using switching hubs. • Reducing the number of monitoring devices of the GOT. Product name Model name Quantity Ethernet communication unit GT15-J71E71-100 1 Mounting screw set (2 pieces of screw,2 pieces of label) -1 For information concerning necessary OS in case of using GT15- J71E71-100,refer to GOT 1000 Series Connection Manual. Item Specification Transmission specifications Data transfer method 10BASE-T 100BASE-TX Transmission method Base band Base band Maximum node to mode distance 200m 200m Maximum segment length 100m 100m Maximum number of cascade connection 4 steps 2 steps Number of units mounted to GOT Only 1 unit can be mounted to the extension unit interface. Connecting condition Number of GOTs connected 128 (Recommend 16 or less)*1*2 GOT placing distance 100m*1 Internal current consumption(DC5V) 0.22A Weight 0.09kg 2.2 Specifications of the related devices Use the connection cable and the hub which meet the IEEE802.3 10BASE-T/100BASE-TX standard. 3. Name of the Parts Item Specifications 10BASE-T 100BASE-TX Cable Non-shielded twisted pair wire (UTP cable) (category3(4, 5)) Shielded twisted pair wire (STP cable) (category5) Connector RJ45jack RJ45jack Hub 10Mbps hub 100Mbps hub No. Name Description 1) Mounting screw Mounting screws fixed with the front communication unit or GOT. 2) Interface connector Connector connected to the front communication unit or GOT. 3) Extension connector Connector with which the back communication unit is fixed. 4) Ethernet connector Connector to which Ethernet cable is connected. 5) 100M LED It lights up during 100 Mbps transmission. 6) SD/RD LED It blinks during data sending/ receiving. 7) Rating plate - 1) 7) 3) 2) 6) 4) 5) 4. Installation Procedure (1) Power off the GOT. (2) Remove the one extension unit covers of the GOT. (3) Fit the Ethernet communication unit along the groove of the GOT case. (4) Fasten the Ethernet communication unit by tightening its mounting screws (2 places) with tightening torque 0.36 to 0.48 N•m. (5) When mounting an Ethernet communication unit on the outer layer, remove the connector cover and the seal. When not mounting any communication unit on the outer layer, stick accessory labels on the top of mounting screws (2 places) to cover the top of them in order to avoid receiving electrostatic. Keep the connector cover fixed. Keep the seal stuck as it is. Seal A ccessory labels Connector cover 5. External Dimensions Dimensions of X when mounted to the GOT. Unit: mm (inch) Point (1) Grounding work for the 10BASE-T and 100BASE-TX requires appropriate safety measures. Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables. (2) If you remove the Ethernet unit, detach it from specified direction (shown PULL) so as not to break a connector. 8.4” 23 (0.91) 10.4”, 12.1”, 15” 21 (0.83) Ethernet is a registered trademark of Xerox Corporation, U.S. Other business or product names mentioned herein are a trademark or registered trademark of each company. 2.5 (0.10) 21 (0.83) 3 (0.12) 63 (2.48) GOT main unit 0.5 (0.02 ) 98 (3.89) 112 (4.41) 0.4 7 (0.28) (0.31) 8 30.5 (1.2) 21.5 (0.85) X (0.02) Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. For safe use • This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. • Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. • This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. C ountry/Region Sales office/Tel U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo, SP Brazil Tel : +55-11-5908-8331 G ermany Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344 S pain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French Branch 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France TEL: +33-1-5568-5568 S outh Africa Circuit Breaker Industries LTD. Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000 Hong Kong Ryoden Automation Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870 C hina Ryoden Automation Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6120-0808 T aiwan Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552 S ingapore Mitsubishi Electric Asia Pte, Ltd. 307 Alexandra Road #05-01/02, Mitsubishi Electric Building Singapore 159943 Tel : +65-6473-2308 T hailand F. A. Tech Co.,Ltd. 898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Tel : +66-2-682-6522 Indonesia P.T. Autoteknindo SUMBER MAKMUR Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan Industri/Pergudangan Jakarta - Utara 14440 Tel : +62-21-663-0833 India Messung Systems Put,Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI, PUNE-411026, India Tel : +91-20-712-2807 A ustralia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777 HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications subject to change without notice. Printed in Japan on recycled paper.
Amplifier PR-101NR Guide, #4CO8K7
PR-101NR, 68, akitika/pr-101nr.pdf
Eusso Reference Book: UNC 7800 series (#36HDA4)
UNC 7800 series, 54, eusso/unc-7800-series.pdf
#7YD719: Model II Instruction
Model II, 2, perreaux/model-ii.pdf
Polaris Camcorder Manual (#BT311U)
D7500, 28, polaris/d7500.pdf
User Guide (F100X, #T95A2C)
F100X, 104, yamaha/f100x.pdf
Lexmark All in One Printer Manual (#HBT822)
X782, 5, lexmark/x782.pdf
#1B8CQU: TOV211DEH Instruction
TOV211DEH, 23, toastmaster/tov211deh.pdf
Handbook (PC-300, #J8I2TI)
PC-300, 128, roland/pc-300.pdf
Hot Tub Document #92LX81
ESTATE AIR-WHIRLPOOL, 28, aquatic/estate-air-whirlpool.pdf
U33024 EOB31010X Oven - #JYAU93
U33024 EOB31010X, 40, electrolux/u33024-eob31010x.pdf
PRODUCT DATASPA400Internet Telephony GatewayModel No.Advanced Multi-Port PSTN Gateway Solution for the Linksys Voice SystemIntegrated Voicemail Application Server with up to 32 Voicemail AccountsPerfectly Suited to Connect up to 4 Analog LinesFunctions as an Analog Line Gateway for a ...
Model & Doc Type: SPA400 4
E6581542① TOSVERT VF-PS1 series APOGEE® FLN option unit Function Manual APG001Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of APOGEE® FLN option unit. 2. Read this manual before installing or operatin ...
Model & Doc Type: APG001Z 28
Schottky Barrier Diodes (SBD)1Publication date: April 2004 SKH00087CEDMA3X787 (MA787)Silicon epitaxial planar typeFor super high speed switchingFor small current rectification■ Features• Forward current (Average) IF(AV) = 100 mA rectification ispossible• Optimum for high frequency re ...
Model & Doc Type: MA3X787 (MA787) 3
Dialogic® DM/N1200-4E1-cPCI Digital Telephony Interface Board Quick Install Card for CompactPCI Part Number 64-0075-02 Copyright © 2003-2007 Dialogic Corporation. All Rights Reserved. Before You Begin Protecting the Board from Damage CAUTION: All computer boards are sensitive to elect ...
Model & Doc Type: DM/N1200-4E1-cPCI 2
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | EAW | CobraNet CM-1 |
1 | 0.3 Mb | 30/12 | |
2 | AMX | AXC-INP8 |
1 | 0.06 Mb | 16/11 | |
3 | Texas Instruments | Technology for Innovators 4Q 2006 |
49 | 22/01 | ||
4 | aqprox! | appPCI1000V2 |
40 | 03/04 | ||
5 | Supermicro | AOC-A25G-b2S |
29 | 15/02 | ||
6 | VOIspeed | V-6017 |
22 | 02/03 | ||
7 | ZyXEL Communications | NXC-8160 |
205 | 5.83 Mb | 20/10 | |
8 | Zhone | Copper-Based Ethernet |
8 | 0.98 Mb | 01/03 | |
9 | HP | Compaq NC4000 |
44 | 31/01 | ||
10 | BOSER Technology | Industrial Single Board Computer HS-6038 |
86 | 3.16 Mb | 08/11 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | JohnsonSuisse | Gemelli JBTG2150 |
4 | 22.10.2023 | ||
2 | Beko | BFR630DX |
31 | 16.10.2023 | ||
3 | Viking | R-6S |
49 | 05.04.2024 | ||
4 | LG | WF-HX150V |
48 | 19.03.2024 | ||
5 | HydroTools | 8940H |
6 | 07.11.2023 | ||
6 | BenQ | Joybee 120 |
74 | 10.02.2024 | ||
7 | Polaroid | PDC 3350 |
63 | 05.03.2024 | ||
8 | Canon | Power Shot A400 |
142 | 1.84 Mb | 10.12.2023 | |
9 | Elsner | KNX B4-UP |
16 | 13.03.2024 | ||
10 | Bionizer | Eco - Oxidizer |
16 | 18.02.2024 |