Nordyne Single Package Heat Pump User's Manual & Installation Instructions

User's Manual & Installation Instructions for Nordyne Single Package Heat Pump Heat Pump (16 pages)

Specifications:

585/585603-single_package_heat_pump.pdf file (06 Apr 2024)
  • Manufacturer: Nordyne
  • Category of Device: Heat Pump
  • Document: Single Package Heat Pump, File Type: PDF User's Manual & Installation Instructions
  • Updated: 06-04-2024
  • Count of Pages: 16
Download Single Package Heat Pump Manual (16 pages)

Read PDF Document Online:

Data: UPD 6th April 2024

Nordyne Single Package Heat Pump Heat Pump PDF User's Manual & Installation Instructions (Updated: Saturday 6th of April 2024 09:31:59 AM)

Rating: 4.3 (rated by 73 users)

Compatible devices: Q3RA-036K, GR4G*090 Series, T5BP Series, 13 SEER, iQDrive Split System Heat Pump, Q5RD Series, Q4SD-X24K, Q4SE Series /installation.

Recommended Documentation:

Text Version of Nordyne Single Package Heat Pump Heat Pump Manual (Summary of Contents)

(Ocr-Read of Nordyne Single Package Heat Pump Document (Main Content), UPD: 06 April 2024)
  • 3, Nordyne Single Package Heat Pump 3 use of electric resistance heat in place of the heat pump will result in an increase in electric utility costs. Defrost — During cold weather heating opera- tion, the outdoor unit will develop a coating of snow and ice on the heat transfer coil. This is normal and the unit will…

  • 14, 14 13 SEER - Refrigerant Charging Tables for Cooling Mode of Operation Continued * Note: All pressures are listed in psig. and all temperatures in °F. - Shaded Boxes indicate flooded conditions - Rated Design Values. Suction Pressure will be lower than design value if indoor …

  • 7, 7 Figure 8. Motor Lead Connection Note: For highly resistive duct systems it may be necessary to add an additional return air duct and or supply to achieve maximum performance and prevent coil icing and refrigerant fl ood back. THE HEAT PUMP SYSTEM WILL NOT COOL OR HEAT THE…

  • 8, 8 CONDENSATE DRAIN A 3/4” condensate fi tting extends out of the side of the unit. The drain trap, shipped in the electrical compartment, must be installed to prevent water from collecting inside the unit. Thread the elbow provided with the unit into the drain connection until hand tight.…

  • 12, 12 13 SEER - Refrigerant Charging Tables for Cooling Mode of Operation * Note: All pressures are listed in psig. and all temperatures in °F. - Shaded Boxes indicate flooded conditions - Rated Design Values. Suction Pressure will be lower than design value if indoor air flow…

  • 5, 5 Figure 4. Return Air Box shipped in the supply duct. They attach to the unit openings with a fl ange and bead arrangement, secured with two sheet metal screws. Note: For ease of access, install fi tting before positioning unit in fi nal location. SUPPLY DUCT Position the supply duc…

DOC-7d2836d5:

Recommended:
917.255950, SFET07, S1, MK-100 TRACKER

CDU4524EGF-S, WHP49230R, Air Eagle 717, 4SHP13 series, BW/WW, BPM400A
  • 506762-01 Page 1 of 24Issue 1143The equipment covered in this manual is to be installed by trained and experiencedservice and installation technicians. Improper installation, modification, service, oruse can cause electrical shock, fire, explosion, or other conditions which may ...

    Model & Doc Type: 4SHP13 series 24

  • WINDOW HEAT PUMP USER MANUAL 950-0190revD 02/19/2014 FOR MODELS: COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9,200/9,500 BTU 11,200/11, ...

    Model & Doc Type: WHP49230R 19

  • Montage- und GebrauchsanweisungInstructions d’installation et d’utilisationInstallation andOperating InstructionsSole/Wasser-Wärmepumpe für InnenaufstellungSI 90TUBrine-to-Water Heat Pump for Indoor InstallationPompe à chaleur eau glycolée-eau pour installation intérieureSI 130 ...

    Model & Doc Type: SI 90TU 72

  • AIR-WATER AND WATER-WATER UNITS FOR HYDRONIC SYSTEMS hƐĞƌDĂŶƵĂů^ĞƌŝĞƐŚŝůůĞƌƐΘ,ĞĂƚWƵŵƉƐhŶŝƚƐ            � ...

    Model & Doc Type: IPG315D 53

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Gullberg & Jansson
X15
93 07/03
2 Pridiom
PCM123HX
41 11/12
3 Dimplex
LI 20TEL
27 1.79 Mb 16/02
4 Vaillant
flexoTHERM exclusive VWF 87/4
20 28/01
5 Day and Night
R4H3
18 28/03
6 Nibe
AHPS
28 08/02
7 Panasonic
WH-MXF09D3E8
125 12/11
8 York
YLHA 50
28 0.94 Mb 15/03
9 Daikin
FAQ71BUV1B
19 14/04
10 Mitsubishi Electric
EHSE-YM9EC
76 10/02

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Dr. Trust
Afib
26 28.01.2024
2 AMX
DG DVI MTP
2 0.83 Mb 26.02.2024
3 Delta
RetroSign GRX-1
80 14.03.2024
4 Panasonic
ES-LV61
36 16.01.2024
5 Hunter
42122
2 08.02.2024
6 Arris
Touchstone TM402
61 09.10.2023
7 Kia
RIO 2015
11 14.02.2024
8 DeLonghi
BG14
12 24.02.2024
9 Pioneer
DEH-P360 - XM Ready CD Receiver
7 20.12.2023
10 De Vielle
DEF769099
8 16.01.2024
Operating Impressions, Questions and Answers: