Intel SR2625UR - Server System - 0 MB RAM Quick Start Manual

Quick Start Manual for Intel SR2625UR - Server System - 0 MB RAM Desktop (1 pages)

Specifications:

473/473551-sr2625ur__server_system__0_mb_ram.pdf file (29 Jan 2024)
  • Manufacturer: Intel
  • Category of Device: Desktop
  • Document: SR2625UR - Server System - 0 MB RAM, File Type: PDF Quick Start Manual
  • Updated: 29-01-2024
  • Count of Pages: 1
Download SR2625UR - Server System - 0 MB RAM Manual (1 pages)

Read PDF Document Online:

Data: UPD 29th January 2024

Intel SR2625UR - Server System - 0 MB RAM Desktop PDF Quick Start Manual (Updated: Monday 29th of January 2024 08:28:56 AM)

Rating: 4.3 (rated by 97 users)

Compatible devices: DP43BF, PC On A Stick, Compute Stick STK1A32SC, AXXROMBSASMR, NUC7CJYSAL, NUC8i7HNK, NUC8i5BEH, NUC8i7HN.

Recommended Documentation:

Text Version of Intel SR2625UR - Server System - 0 MB RAM Desktop Manual (Summary of Contents)

(Ocr-Read of Document's Main Page, UPD: 29 January 2024)


Intel is a registered trademark of Intel Corporation or its 
subsidiaries in the United States and other countries.  
*Other names and brands may be claimed as the property 
of others.  Copyright © 2010, Intel Corporation.  
All rights reserved.
Warning
  Read all caution and safety 
  statements in this document 
  before performing any of the 
instructions.  Also see the Intel
®
 
Server Board and Server Chassis 
Safety Information document at:
http://support.intel.com/support/
motherboards/server/sb/cs-010770
.htm for complete safety information.
Warning
  Installation and service of 
  this product should only be 
  performed by qualified service 
personnel to avoid risk of injury from 
electrical shock or energy hazard.
Tools Required
Caution
  Observe normal ESD
  [Electrostatic Discharge]
  procedures during system 
integration to avoid possible 
damage to server board and/or 
other components.
        Anti-static
wrist strap
     Phillips*
screwdriver
Intel
®
 Server System SR2625UR
Quick Start User's Guide
If you are not familiar with ESD (Electrostatic Discharge) procedures 
used during system integration, please see the Intel
®
 Server System 
SR2600UR/SR2625UR Service Guide, available on the Intel
®
 Server Deployment 
Toolkit CD or at 
http://support.intel.com/support/motherboards/server/s5520ur/.
Read all cautions and warnings first before starting your server system integration.
Thank you for buying an Intel
®
 Server System.  
The following information will help you 
assemble your Intel
® 
Server System 
SR2625UR (Product Codes: SR2625URLX, SR2625URLXT, and SR2625URBRP) 
and install components. 
This guide and other supporting documents 
are located on the web at 
http://support.intel.com/support/motherboards/server/s5520ur/.
E52453-005
Please boot to the Intel
®
 Server Deployment Toolkit CD first for BIOS and firmware
configuration and updates.
1
Preparing
the Chassis
Observe normal ESD 
(Electrostatic Discharge) 
procedures.
Place your 
Intel
®
 Server 
Chassis on a flat anti-static 
surface to perform the 
following integration 
procedures. Observe ESD 
procedures before 
reaching inside to make 
server board connections 
or install components.
IMPORTANT!
Before proceeding further, 
check your Intel
®
 Server 
System for disconnected 
or loose cables and 
components that may 
have occurred during 
shipping.
2
Remove the 
Top Cover
B
Remove the security screw.
Depress the latch.
C
Slide cover back and lift upward.
A
A
B
C
4
Remove the 
Processor
Air Duct
Remove processor air 
duct by lifting straight
up as shown.
Processor
Air Duct
3
Remove Add-in 
Card Riser Assembly
Grasp the riser assembly with both hands and 
pull up to release it.
Lift straight up.
          CAUTION:
Place the 
riser assembly 
upside down
to avoid damage 
to the riser card 
connector.
Riser
Assembly
Snap
Standoff
I/O Connector 2
Minimum Hardware Requirements
To avoid integration difficulties and 
possible board damage, your system must 
meet the following minimum requirements:
• Memory Type:  Minimum of one 
  512-MB, 240-pin DDR3 
  800/1066/1333-MT/s DIMMs.
 
• Processor: Intel
®
 Xeon
®
 processor 
  5500 series with 2 MB cache support.
• Hard Disk Drives:
  SATA/SAS
• Rack Mount Kit 
   (EIA 310-D compliant)
 For a complete list of compatible 
    processors, heatsinks, and memory, see
  http://support.intel.com/support/
    motherboards/server/s5520ur/ 
6
Install the Processor(s)
F.   Close Load Plate and 
    Socket Lever
D.   Remove the 
    Processor 
    Protective Cover
Take the processor 
out of the box and 
remove the 
protective shipping 
cover.
A
A
C.   Remove the Socket 
    Protective Cover
Save the protective cover 
for future use.
Grasp the socket protective cover 
by the two tabs and carefully lift 
straight up.
A
To avoid damage, DO NOT 
DROP the cover onto the 
socket wires or components.
Orient the processor with the 
socket such that the orientation 
notches on the processor align 
with the two orientation posts 
on the socket.
A
Install the processor as shown.
Close the load 
plate all the 
way as 
shown.
Close the socket lever and 
ensure that the load plate tab 
engages under the socket 
lever when fully closed.
B
A
A
A
Orientation Notch
Orientation Post
E.  Install the Processor
  CAUTION:
  The underside of the 
processor has components 
that may damage the socket 
wires if installed improperly.
Components
Processor must align 
correctly with the socket 
opening before installation.
DO NOT DROP processor 
into the 
socket!
A.  Open the Socket 
    Lever
Push the lever handle 
down and away from 
the socket to 
release it.
Rotate the lever open 
all the way.
B.   Open the Load Plate
Push the rear tab with your 
finger tip to bring the front 
end of the load plate 
up slightly.
Open the load plate 
as shown.
A
B
A
B
A
B
Read all Cautions before proceeding.
When unpacking a processor, hold 
by the edges only to avoid touching 
the gold contact wires.
NOTE: If you are only using one processor 
on your server board, install the processor 
on the CPU socket labeled ‘CPU 1’ on the 
server board.
When opening a socket, DO NOT 
TOUCH the gold socket wires.
B
A
10
Install Intel® Remote Management Module 3 (optional)
Attach the module bracket to
the chassis with two screws as 
shown. Note that screws install 
from the back of the chassis. 
Attach the RMM3 module bracket to the RMM3 module with two screws as shown.
Connect one end of the cable (labeled 'RMM3') to the RMM3 connector on the RMM3 module.  Note that cable
connectors are keyed and can only go in one way.
Connect the opposite end of the cable (labeled 'server board') to the RMM3 connector on the server board.
B
Squeeze the sides of the RMM3 filler panel to disengage it from the server system back panel and remove it.
A
C
D
E
D
E
RMM3
Connector
RMM3 Module
A
B
C
Top View
Bottom
9
Install I/O Expansion Module (optional)
Position the module
over the server 
board, fit the front 
of the module into 
the back panel 
slot(s), and then 
attach the module to
the server board 
connector and 
engage the standoffs.
Install the standoffs to the server board by pressing into the holes as shown.
Note: For the 1-socket module, 
install three standoffs as 
shown in gray. For the 
2-socket module, 
also install the 
fourth standoff as 
shown in red.
Squeeze the sides of the filler panel(s) to disengage it from the server system back panel and 
remove it.  Note: If you are installing an I/O expansion module that uses only one slot, remove the 
filler panel  only from the slot shown so that the module can be attached to I/O Connector 1; do 
not remove the filler panel from the other slot.
A
B
C
1-Socket
I/O Exp. Module
Standoff
Hole
2-Socket
I/O Exp. Module
I/O Connector 1
A
B
C
Filler Panels
Fourth
Standoff
Position
I/O Connector 2
Snap
Standoff
8
Install Memory DIMMs
To Install DIMMs:
Memory Configurations and Population Order:
Note:  For additional memory configurations, see the Service Guide 
on the Intel
®
 Server Deployment Toolkit CD that accompanied 
your Intel
®
 Server System SR2625UR, or go to:  
http://support.intel.com/support/motherboards/server/s5520ur/ 
Memory sizing and configuration is supported only for qualified 
DIMMs approved by Intel. For a list of supported memory, see the 
tested memory list at:  
http://support.intel.com/support/motherboards/server/s5520ur/compat.htm
For best performance, a minimum of three DIMMs per CPU is recommended.  
In a single-processor configuration, always populate A1 DIMM first.  In a 
dual-processor configuration, always populate A1 DIMM first for CPU 1 and D1 DIMM 
first for CPU2.  In order to maintain adequate thermal levels, DIMMs or DIMM 
blanks must be installed in the DIMM slots as per the following requirements:
•  If you have only one processor installed, all CPU 1 DIMM slots 
  must either have a DIMM or DIMM blank installed.  You may 
  either leave the CPU 2 DIMM slots empty or store extra 
  blanks in the blue DIMM slots.
•  If you have both processors installed, all blue DIMM slots in 
  CPU 1 and CPU 2 must either have a DIMM or a DIMM blank 
  installed.  You may store extra DIMM blanks in any of the 
  unused CPU 1 DIMM slots.
Open both DIMM socket levers.
Push down firmly on the DIMM until it
snaps into place and both levers close.
Insert DIMM making sure the connector edge 
of the DIMM aligns correctly with the slot.
C
A
D
IMPORTANT!  Visually check that each
latch is fully closed and correctly
engaged with each DIMM edge slot.
E
Note location of alignment notch.
B
CAUTION:  Avoid touching contacts 
when handling or installing DIMMs.
A
C
D
B
E
DIMM A2
DIMM A1
DIMM C1
DIMM C2
DIMM B1
DIMM B2
Chan A
Chan B
Chan C
CPU Socket 1
DIMM F1
DIMM F2
DIMM D2
DIMM D1
DIMM E2
DIMM E1
Chan F
Chan E
Chan D
CPU Socket 2
5
Remove the Heatsink(s)
The heatsink is attached to the server board /
processor socket with captive fasteners.
Using a #2 Phillips* screwdriver, loosen the four 
screws located on the heatsink corners in a 
diagonal manner using the following procedure:
Lift the heatsink straight up.
A
D
TIM
Remove the
Spacer
This Side Up
Discard to Install CPU
IMPORTANT:  This spacer must be
removed and discarded before
opening the socket to install the
processor in Step 6.
This Side Up
Discard to Install CPU
  CAUTION: The heatsink has thermal interface 
  material (TIM) on the underside of it.  Use caution so 
      that you do not damage the thermal interface material.  
  Use gloves to avoid sharp edges.
  Using a #2 Phillips* screwdriver, start with 
  screw 1 and loosen it by giving it two rotations 
  and stop. (IMPORTANT: Do not fully loosen.) 
  Repeat steps A and B by giving each screw 
  two rotations each time until all screws are 
  loosened.
  Proceed to screw 2 and loosen it by giving it two 
  rotations and stop. Similarly, loosen screws 3 
  and 4. 
B
C
A
D
7
Install the Heatsink(s)
TIM
Each heatsink has four captive fasteners and should be tightened in a 
diagonal manner using the following procedure:
Note:  Heatsink styles may vary.
Remove the protective film on the TIM if present.
  Using a #2 Phillips* screwdriver, start with screw 1 and engage screw
          threads by giving it two rotations and stop. (Do not fully tighten.)  
  Repeat steps C and D by giving each screw two rotations each time 
  until each screw is lightly tightened up to a maximum of 
  8 inch-lbs torque.
  Proceed to screw 2 and engage screw threads by giving it two 
  rotations and stop. Similarly, engage screws 3 and 4. 
D
  CAUTION: The heatsink has thermal interface 
  material (TIM) on the underside of it.  Use caution so 
      that you do not damage the thermal interface material.  
  Use gloves to avoid sharp edges.
E
C
A
Align heatsink fins to the front and back of the chassis 
for correct airflow. Airflow goes from front-to-back 
of chassis.
B
IMPORTANT NOTE:
This Intel® Server Chassis requires passive heatsinks.
2
3
1
4
CAUTION:
Do not 
over-tighten
fasteners.
Air Flow
Chassis Front





DOC-a1cda30d:

Recommended:
UTP104P-HD, SOLOGIC B921, Yak 54, WVT50C

IMAC - ALL-IN-ONE DESKTOP - 3.06GHz Intel Core 2 Duo, 21J0380 - X 772e MFP Color Laser, NewHeights RECTANGULAR 3-LEG WORKSTATION, ProLiant 1000, ThinkPad R60 9457, IIc
  • ENInstruction & User ManualTeleSafe Mobile Tower (S008)Assembly instructions should be followed carefully201702-IE-12601. Assembling of the Mobile Tower· Make sure that the product delivered to you with a proper strech lm wrapped package without a missing part.· (Figure-1) First, car ...

    Model & Doc Type: TeleSafe S008 2

  •  iMac (Flat Panel) Memory, SO-DIMM Installation Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written and video instructions covering customer-installable parts are avai ...

    Model & Doc Type: IMAC - ALL-IN-ONE DESKTOP - 3.06GHz Intel Core 2 Duo 6

  • ™ZZZGHOOFRP'HOO3UHFLVLRQ:RUN6WDWLRQ0LQL7RZHU6\VWHPV'RFXPHQWDWLRQ8SGDWH0LVHjMRXUGHODGRFXPHQWDWLRQGHVV\VWqPHVPLQLWRXU'HOO3UHFLVLRQ:RUN6WDWLRQ'HOO3UHFLVLRQ:RUN6WDWLRQ� ...

    Model & Doc Type: Precision 610 8

  • English ............................................................................1Deutsch.........................................................................71Français ......................................................................141Italiano ................................... ...

    Model & Doc Type: Essentio CM6340 562

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Asus
TS300-E5 - 0 MB RAM
208 14.74 Mb 07/04
2 HP
Presario SR1700 - Desktop PC
16 0.15 Mb 29/11
3 Dell
XPS 710
105 10/12
4 HP
AB500A - Integrated Lights-Out Advanced
235 6.15 Mb 11/11
5 Elo TouchSystems
X2
48 16/10
6 Sony
VAIO VGX-XL1
123 3.94 Mb 12/10
7 Dell
Vostro 260
71 6.64 Mb 16/01
8 HP
Compaq NC4000
10 24/03
9 MITS
altair 680b
94 26/10
10 ABB
Totalflow G5 Series
20 02/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Droidworx
Mini
23 16.04.2024
2 Motorola
TIMEPORT 280
214 17.03.2024
3 LevelOne
WAP-0005
108 20.10.2023
4 Koukaam
NETIO-230B
2 25.01.2024
5 Toshiba
24AF43
40 1.99 Mb 17.01.2024
6 Parkside
PGG 15 A1
85 16.02.2024
7 Baja motorsports
HT65
53 1.67 Mb 03.04.2024
8 Premier
MS-4780USD2
11 28.01.2024
9 Canon
ImageCLASS MF4570dw
2 4.22 Mb 12.04.2024
10 D-Link
DSM-750 - MediaLounge High-Definition Draft N Media Player
124 11.01.2024
Operating Impressions, Questions and Answers: