Thermo King MAGNUM Maintenance Manual

Maintenance Manual for Thermo King MAGNUM Air Conditioner (196 pages)

Specifications:

830/830401-magnum.pdf file (04 Oct 2023)
  • Manufacturer: Thermo King
  • Category of Device: Air Conditioner
  • Document: MAGNUM, File Type: PDF Maintenance Manual
  • Updated: 04-10-2023
  • Count of Pages: 196
Download MAGNUM Manual (196 pages)

Read PDF Document Online:

Data: UPD 4th October 2023

Thermo King MAGNUM Air Conditioner PDF Maintenance Manual (Updated: Wednesday 4th of October 2023 07:55:02 PM)

Rating: 4.8 (rated by 46 users)

Compatible devices: SB-210+, WM1-15E-01, PEAD-RP35EA, FAH124N2, AJHS 08 DCB, SH18AW6, MH14VA1 Seies, MM Series.

Recommended Documentation:

Text Version of Thermo King MAGNUM Air Conditioner Manual (Summary of Contents)

(Ocr-Read of Thermo King MAGNUM Document (Main Content), UPD: 04 October 2023)
  • 133, Thermo King MAGNUM Refrigeration Maintenance 132 3. Remove small service port caps from suction and discharge service fittings. Save and reuse the caps and sealing washers or gaskets. 4. Rotate both hose coupler hand wheels counterclockwise to back the stem out of the high and low hose fittings. Attach low …

  • 160, Diagnosis: Troubleshooting, Status Messages, Alarm Codes 159 Troubleshooting Refrigeration Problems Condition Possible Cause Remedy Load temperature too high— unit not cooling Compressor does not operate See “Mechanical Diagnosis” Controller setpoint too high Adjust controller setpoint De…

  • 113, Operating Theory 112 the time interval each timed defrost interval. Defrost synchronization creates step intervals of 3, 4, 4, 5, 5, 6, 6 and 7 hours. Maximum time interval is 7 hours. • On Frozen Loads, the initial time interval is 8 hours. Two (2) hours are added to the time interval eac…

  • 150, Refrigeration Maintenance 149 Figure 97: Vapor Injection Valve Vapor Injection Valve Replacement NOTE: In most cases, only the coil requires replacement. No other repair is possible on solenoid valves. Valve Removal To remove the vapor injection valve, perform the following steps: 1. R…

  • 27, Specifications 26 Physical Specifications Fresh Air Exchange Venting System (Adjustable): MAGNUM and MAGNUM SL 0 to 285 m 3 /hr (0 to 168 ft 3 /min.) @ 60 Hz 0 to 237 m 3 /hr (0 to 139 ft 3 /min.) @ 50 Hz MAGNUM 20 0 to 160 m 3 /hr (0 to 96 ft 3 /min.) @ 60 Hz 0 to 134 m 3 /hr (0 to 79 ft 3 /min.…

  • 98, Operating Instructions 97 NOTE: If the inlet / outlet tubes or filter need to be cleared, disconnect from the gas analyzer BEFORE purging air through the tubes. If tubes remain connected, serious damage to the gas analyzer could occur. Code 69 Gas Analyzer Calibration (Normal) 1. Stale atmosp…

DOC-d4f19d9a:

Recommended:
SHDUG, Traffic Receiver, 30245, Voyager 60

i-ACCURATE Series i-AX, R410A, VTC Series, MGHP-12, PLFY-P·NCMU-E
  • PELER CHILLISTRUZIONI PER INSTALLAZIONE, USO E MANUTENZIONEINSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCEMODE D’EMPLOI ET D’ENTRETIENINSTRUCCIOES PARA LA INSTALACIÓN, USO Y MANTENIMIENTOITENFRESINSTRUÇÕES DE USO E MANUTENÇÃOPTDEGEBRAUCHS-, INSTALLATIONS- UND WARTUNGSANWEISUNGEN ...

    Model & Doc Type: Peler Chill 86

  • 1INSTALLATION INSTRUCTIONSSplit System Air ConditionerThis air conditioner uses the refrigerant R410A.NOTEExternal diameter of service port R410A: 5/16"Model No.Outdoor UnitsType Outdoor Unit Type 26 36 42 RemarksU SingleU-26PE1U6 U-36PE1U6 U-42PE1U6 Cooling/HeatingU-26PS1U6 U-36PS1U6 U-42PS ...

    Model & Doc Type: R410A 40

  • IMPORTANTThese air conditioners employ newrefrigerant R410A.Pay special attention whenservicing the unit.TECHNICAL & SERVICE MANUALKHS0971 + CH0971KHS1271 + CH1271DC INVERTER SPLIT SYSTEM AIR CONDITIONERIndoor UnitDestination: North AmericaOutdoor Model No.CH0971CH1271Product Code No.1 852 ...

    Model & Doc Type: CH0971 104

  • q Installation & User’s Guide q Guia Para Instalacih y Uso q Guide d’installation et mode d’emploi 1. Air direction tab 2. Air louvers 3. Front panel 4. Control panel 1. Tablilla de direccih 1. Bouton de rhglage de la de aire circulation de I’air 2. Rejil ...

    Model & Doc Type: BHAC0600BS0 40

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Daikin
FVXS60KVMA
35 1.72 Mb 08/02
2 intensity
IDCC090KF-5
9 18/02
3 Mitsubishi Electric
MXZ-2A40VA
98 07/03
4 Daikin
altherma ERHQ011BAV3
28 08/01
5 Fujitsu
GENERAL ASHG18KMTA
59 24/01
6 Mitsubishi Electric
MSZ-GE09NA
48 11/03
7 nedis
COOL116CWT
28 11/11
8 Bard
W12AAA
21 08/12
9 Samsung
AS07A5MA
47 20/01
10 inventum
VLK401WA
36 10/03

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 SRAM
Guide RS
32 12.10.2023
2 Fermax
SMILE 3.5” Monitor
55 09.02.2024
3 Black & Decker
BDPC400AU
4 23.04.2024
4 Kenwood
AS-5
8 25.01.2024
5 InSinkErator
Evolution Series
16 25.10.2023
6 Bunn
VP17 Series
16 08.12.2023
7 Numatic
PPH 320A
12 02.11.2023
8 Neptronic
SKG3 Series
58 02.04.2024
9 Dali
E-50
40 16.10.2023
10 Cisco
2948G - Catalyst Switch
3 0.14 Mb 23.01.2024
Operating Impressions, Questions and Answers: