Omron NE-U17 Instruction Manual

Instruction Manual for Omron NE-U17 Medical Equipment (144 pages)

Specifications:

821/821865-neu17.pdf file (16 Apr 2024)
  • Manufacturer: Omron
  • Category of Device: Medical Equipment
  • Document: NE-U17, File Type: PDF Instruction Manual
  • Updated: 16-04-2024
  • Count of Pages: 144
Download NE-U17 Manual (144 pages)

Read PDF Document Online:

Data: UPD 16th April 2024

Omron NE-U17 Medical Equipment PDF Instruction Manual (Updated: Tuesday 16th of April 2024 12:30:16 AM)

Rating: 4.9 (rated by 32 users)

Compatible devices: Total Power + Heat PM800, CS2 Small Cuff, HHX-IT3-Z, CL2, HV-F021-EW, NE-C28-E, HEM-CS24, PocketTens.

Recommended Documentation:

Text Version of Omron NE-U17 Medical Equipment Manual (Summary of Contents)

(Ocr-Read of Omron NE-U17 Document (Main Content), UPD: 16 April 2024)
  • 87, 14 FR Comment inhaler en utilisant des accessoires en option Une fois passé par un filtre bactérien, l’air filtré peut être amené en direction du kit de vaporisation longue durée. ➀ Retirez le couvercle du gobelet et raccordez le kit de vaporisation longue durée à l’appareil. Pour ré…

  • 20, 19 Troubleshooting Trouble The power lamp does not illuminate. The unit does not nebulise. The nebulisation rate is low. The nebulisation power is lowered. Nebulisation is unstable. Where to Inspect Is the power plug securely plugged into the electric outlet? Is ➀ of ERROR display flashi…

  • 127, Omron NE-U17 6 ES Características del producto Acerca del principio de nebulización en la NE-U17 ➀ La NE-U17 transmite al agua la energía de la vibración ultrasónica del vibrador situado en el fondo del tanque de agua. ➁ La vibración ultrasónica se transmite a la medicación del recipiente …

  • 21, 20 Specifications Technical data Product name : Omron Ultrasonic Nebuliser Model : NE-U17 (NE-U17-E) Power source : 230 VAC, 50 Hz Power consumption : Approx. 80 VA Fuse : T2A L250V Ultrasonic frequency : Approx. 1.7 MHz Particle size : * MMAD 4.4 µm (MMAD=Mass Median Aerodynamic Diameter…

  • 113, 16 IT Come prendersi cura dell’apparecchio Come prendersi cura del filtro dell’aria Sostituire il filtro dell’aria quando è sporco. ➀ Rimuovere l’unità di nebulizzazione dall’apparecchio principale. ➁ Rimuovere la copertura della ventola sollevandola verso l’alto. ➂ Rimuovere l…

  • 19, 18 How to Disinfect and Store the Unit Sterilization with ethylene oxide gas (E.O.G.) Observe the Instruction Manual of the sterilizer and consult with the manufacturer of the E.O.G. sterilizer for the details. Some of the rubber and plastic parts of the nebuliser may have residual ethylene ox…

DOC-524c2483:

Recommended:
GE Series, GE 3000 BI, GCM-7800, A05-17AM-L02

HFL-400-P, XLS-300, MyLabX75VET, Drager medical Carina, 27337
  • ITALIANOINTRODUZIONEL’orchidometro è uno strumento utilizzato per fornire una misurazione indica-tiva del volume dei testicoli. È composto da un lo di dodici sfere numerate in legno. Le sfere sono ordinate in ordine crescente da 1 a 25 millimetri. La discrepanza della dimensione dei te ...

    Model & Doc Type: 27337 4

  • Dispenser DP 30Infiltration Pump31678 • V52/17 • NOUVAG AG©, all rights reserved, subject to changeBedienungsanleitungOperation ManualMode d’emploiIstruzione d’usoInstrucciones de uso BedieningshandleidingIstrukcja ObsługiOperačný návodNávod k obsluzeAdagoló Használati ...

    Model & Doc Type: Dispenser DP 30 151

  • 14Y1, 14Y5 Skeo UpGebrauchsanweisung ..................................................................................................... 3Instructions for use ......................................................................................................... 6Instructions d'utilis ...

    Model & Doc Type: 14Y5 SkeoUp 88

  • Gebrauchsanweisung/Technische BeschreibungACCULAN-Bohrmaschine GA 620 DInstructions for use/Technical descriptionACCULAN drill GA 620 DMode d’emploi/Description techniquePerceuse ACCULAN GA 620 DInstrucciones de manejo/Descripción técnicaTaladradora ACCULAN GA 620 DIstruzioni per l� ...

    Model & Doc Type: AESCULAP ACCULAN GA 620 D 104

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 DENTSPLY
Extra Star
24 02/04
2 human care
HeliQ
92 30/03
3 Abbott
FreeStyle Libre
142 02/01
4 Carestream
DRX-Revolution
44 28/01
5 Orthofix
Cervical-Stim 2505CE
137 14/10
6 Iron Bow
MedView-V A01 Series
24 09/12
7 Invacare
Flo-tech PT Anti-Thrust Harness
36 10/01
8 GE
LOGIQ A1
38 29/10
9 Getinge
Arjohuntleigh Maxi Sky 600 ECS
52 24/11
10 Milton Roy
Spectronic 501
31 10/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 HP
Presario SR1200 - Desktop PC
1 0.04 Mb 09.12.2023
2 Mitsubishi Electric
PUHZ-HRP HA2
14 16.11.2023
3 NewAir
AB-1200
11 23.02.2024
4 DigiTech
RP350
40 5.09 Mb 23.01.2024
5 Kenwood
KDC-X998
100 13.11.2023
6 TFA
98.1071
22 11.10.2023
7 Constellation audio
Inspiration PREAMP 1.0
16 22.03.2024
8 Akai
PT50DL24
2 0.21 Mb 14.03.2024
9 Whirlpool
EF19MK
16 1.26 Mb 19.02.2024
10 Akai
AA-V2080
18 0.52 Mb 09.03.2024
Operating Impressions, Questions and Answers: