Specifications:801/801867-glucocard_vital.pdf file (17 Feb 2024)
|
Arkray Glucocard Vital Blood Glucose Meter PDF Quick Reference Manual (Updated: Saturday 17th of February 2024 05:57:41 AM)
Rating: 4.6 (rated by 12 users)
Compatible devices: GLUCOCARD SM, Gluocard Shine Express, Glicocard SHINE, Glucocard SHINE Express, GLUCOCARD Shine Connex, GLUCOCARD 01-mini, Glucocard Shine, Glucocard X-Meter.
Recommended Documentation:
• Was the sample deep red in color and free of watery uid? • Was the drop large enough (at least 0.5 µL)? • Did the reaction site ll with enough blood all at once? IF NOT, REPEAT TEST. The meter will count down and display result in 7 seconds. CONSIDER YOUR RESULT. REPEAT ALTERNATE SITE TEST: • IF the blood sample appeared to be diluted with clear uid. • IF you did not vigorously rub the test site. • IF the test was accidentally marked as a “Control” result. • IF your result was not consistent with how you feel. • IF the blood drop was not large enough to ll the reaction site. Any of the above situations can lead to an inaccurate test result. If the repeated alternate site result is still not consistent with how you feel, conrm your blood glucose level with ngertip testing. < < a) Remove GLUCOCARD Vital test strip from the bottle. Immediately replace the bottle cap tightly. Insert test strip as shown in diagram. Be sure to align test strip with test strip port. b) Make sure all parts of the display screen appear. Test Strip Port Contact Bars Reaction Site Sample Application Tip Insert strip into meter this way IMPORTANT! Enough Blood Not Enough Blood Too Much Blood Enough Blood Not Enough Blood Pick up the meter. Touch the end of the test strip to the blood sample until the reaction site is full. Immediately remove the meter and test strip from the blood drop. Step 4 TROUBLESHOOTING Step 1 Step 2 PERFORMING A BLOOD GLUCOSE TEST Remove GLUCOCARD Vital Test Strip from the bottle. Immediately replace the bottle cap tightly. Insert test strip as shown in diagram. The meter will turn on automatically. Choose a Site: Select a soft, eshy area on the palm that is free of visible veins and moles and away from bone. Wash the area with warm, soapy water. Rinse and dry completely. If you use alcohol wipes to cleanse the site, make sure the area is dry before lancing the site. Step 1 Insert lancet and cock lancing device. Step 2 Step 3 d) Once a large enough drop of blood has formed, remove the lancing device. Step 4 b) Firmly hold the cocked lancing device against the clean skin for 5-10 seconds. a) VIGOROUSLY RUB THE SELECTED AREA for 5 to 10 SECONDS until it starts to feel warm to the touch. IMPORTANT Repeat blood draw if uid is not a deep red color c) Press the release button on the lancing device to lance the skin. Continue to hold the lancing device firmly against the skin until a 0.5 µL blood drop forms. a b c Step 5 Step 6 Always record your results in your self-testing logbook along with other information such as insulin dosage, diet, and exercise. The result is automatically stored in memory with the time and date. Step 7 Step 8 Remove the test strip and dispose of it carefully. The meter shuts off automatically when the test strip is removed. IMPORTANT Manufactured for ARKRAY USA, Inc. 5182 W. 76th St. Minneapolis, MN 55439 USA TEL 800.566.8558 FAX 952.646.3110 www.arkrayusa.com GLUCOCARD ® is a registered trademark of ARKRAY P/N 1855-01 Rev 5/11 When the test is done, remove test strip. Dispose of test strip carefully. The meter shuts off automatically when you remove the test strip. A lancet should only be used once. After use, put the protective cap back on and dispose of in a safe manner to avoid accidental lancet stick injuries. Obtain a blood sample. Apply blood to the end of the test strip. Capillary action will pull the blood to the reaction site. The meter will start to count down when it detects that blood has been applied. Do not add blood on top of the test strip, as you may receive an inaccurate result. Discard strip if meter does not start to count down after blood drop is applied. IMPORTANT: The minimum sample volume is 0.5 µL. Smaller samples may not start the meter or can start the meter count down and provide an “E13” error message. Ensure blood completely lls reaction site. The test result and date/time is displayed in 7 seconds. The result will be automatically stored in memory Results will be shown in units of mg/dL. Record result in your logbook. DO NOT add blood to the top of the strip. You may receive an abnormal (high) result. Insert into meter this way Make sure all parts of the display screen appear. Refer to the GLUCOCARD Vital Blood Glucose Monitoring System user instruction manual for further details. For all other errors call Customer Service at 800.566.8558. Your blood glucose level is less than 20 mg/dL. Repeat the test using a new test strip. If this message appears again, contact your healthcare professional immediately. The battery power is too low for testing. Replace with a new CR2032 battery. The battery power is low. There is only enough power for about 20 more tests. Replace with a new CR2032 battery as soon as possible. Enough Blood Not Enough Blood Too Much Blood CORRECT INCORRECT < < IMPORTANT! Step 3 Your blood glucose level is more than 600 mg/dL. Repeat the test using a new test strip. If this message appears again, contact your healthcare professional immediately. The battery has been replaced. Check that the time and date are set correctly. A used strip has been inserted or the meter is having difficulty reading the strip. Repeat the test with a new test strip. Thermometer flashing. The meter and test strips are outside the optimum temperature range of 50°F - 104°F (10°C - 40°C). Treat test result obtained where the thermometer is ashing with caution. The ashing thermometer will be displayed on all screens during glucose testing until the meter has reached acceptable temperature. Readings obtained with the ashing thermometer will show a thermometer when results are recalled in memory. Thermometer symbol - E6. Temperature outside of acceptable range of 41°F - 113°F (5°C - 45°C). You will not obtain a reading. Allow the meter and strips to warm up or cool down slowly to between 50°F - 104°F (10°C - 40°C) or at least to 41°F - 113°F (5°C - 45°C). Not enough blood was added to test strip. Retest with new test strip. Apply at least 0.5 µL of blood to sample application tip. Test Strip Port Contact Bars Reaction Site Sample Application Tip Consider AST when: • Testing before a meal • You are in a fasting state • Two hours have passed since a meal • Two hours have passed since insulin dosing • Two hours have passed since physical activity PERFORMING A BLOOD GLUCOSE TEST FROM AN ALTERNATE SITE Quick Reference Guide
zd7005QV - Pavilion - Pentium 4 2.66 GHz Laptop - #SQ33RG
zd7005QV - Pavilion - Pentium 4 2.66 GHz, 1, hp/zd7005qv-pavilion-pentium-4-2-66-ghz.pdf
EGO Blower Manual (#5HCGD6)
LB4800, 48, ego/lb4800.pdf
VLZ7U Operation Camcorder - #WS1NZN
VLZ7U Operation, 140, sharp/vlz7u-operation.pdf
Network Card Instruction #2G6G31
Compact USB 2.0, 29, linksys/compact-usb-2-0.pdf
Whirlpool User Guide: RF362LXT (#AHE5SV)
RF362LXT, 7, whirlpool/rf362lxt.pdf
AM90 Air Cleaner - #2R539D
AM90, 28, amcor/am90.pdf
#BP7CT1: Rhythm User Manual
Rhythm, 182, quickie/rhythm.pdf
Panasonic Flat Panel TV Manual (#38L1V5)
TH-47LFX6, 71, panasonic/th-47lfx6.pdf
Handbook (RX-111, #5LRR1M)
RX-111, 5, sven/rx-111.pdf
Konica Minolta Printer Manual (#HVM483)
bizhub 20P, 161, konica-minolta/bizhub-20p.pdf
Step 2: Gather all the supplies needed to perform a test• AlphaTRAK® 2 Meter• Lancet• AlphaTRAK 2 Testing Strips• Vaseline (to help blood form droplets)• Gauze or tissueStep 5: Draw blood Using the lancing device, draw a small amount of blood from the selected testing si ...
Model & Doc Type: AlphaTRAK 2 2
2020 September. Ontario VEP Stellar™150: Care and Use of the Stellar™150 Internal Battery: Stellar™150 Internal Battery Alarm Messages: ©2020 Ontario Ventilator Equipment Pool. All rights reserved. Rev date: 9/28/2020 Care and Use of the Stellar™ 150 Internal Battery a ...
Model & Doc Type: Stellar 150 3
C5 K45C100 M70 K30User’s ManualGeneral Life Biotechnology Co., Ltd.5F., No. 240, Shinshu Rd., Shin Juang Dist., New Taipei City 242, TaiwanTEL : +886-2-22053698FAX : +886-2-22080779E-mail : [email protected] GmbHSchiffgraben 4130175 Hannover, GermanyDoc.#: FIG-540BNK0ADXA-3 Jan, 201 ...
Model & Doc Type: Uni BSG010-1 81
In vitrodiagnostic.For self-testing. IMPORTANT: Please read this insert and your User Guide or Owner's Booklet before using. The User Guide or Owner's Booklet has full instructions for blood glucose and control solution testing. Do Not use new test strips if the vial ...
Model & Doc Type: Verio 2
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Medtronic | MiniMed 640G |
88 | 16/02 | ||
2 | Abbott | FreeStyle |
78 | 27/10 | ||
3 | MHC Medical Products | EasyTouch BluLink |
48 | 12/12 | ||
4 | Fora | COMFORT pro GD40 |
44 | 21/10 | ||
5 | Accu-Chek | COMPACT PLUS |
440 | 20/04 | ||
6 | Bioland | G-423S |
23 | 18/02 | ||
7 | NIPRO Diagnostics | TRUEtrack |
42 | 01/12 | ||
8 | Tunstall | iHealth BG5 |
2 | 30/03 | ||
9 | Wellion | CALLA Light |
52 | 28/10 | ||
10 | Abbott | i-STAT 1 |
7 | 23/11 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | satoh | s-650g |
44 | 07.02.2024 | ||
2 | Keysight | N4375D |
174 | 14.03.2024 | ||
3 | Yamaha | RX-830 |
24 | 3.4 Mb | 27.11.2023 | |
4 | Lovibond | MD 610 |
360 | 21.10.2023 | ||
5 | Olympus | X-705 |
2 | 20.04.2024 | ||
6 | Bender | LINETRAXX VMD461 |
84 | 18.10.2023 | ||
7 | Terasic | BTS-TMD |
16 | 28.11.2023 | ||
8 | Behringer | U-Control UMX610 |
16 | 1.45 Mb | 19.11.2023 | |
9 | Black & Decker | screwdriver |
12 | 27.12.2023 | ||
10 | Silvercrest | SHGD 40 C1 |
63 | 23.02.2024 |