Specifications:894/894167-rxpw4.pdf file (16 Oct 2023)
|
Dimplex RXPW4 Controller, Heating System PDF Quick Start Manual (Updated: Monday 16th of October 2023 04:42:58 AM)
Rating: 4.9 (rated by 66 users)
Compatible devices: DXGLO2, VSH LAK9, KNX WPM, DWF1215, DWF1203, DF2550, TIMRA, Duo300N.
Recommended Documentation:
Quick Start Guide RXPW4 - 4 Zone Pilot Wire Central Controller Controls General Initial set up: Setting the time and day Issue 1: D1227-0106 This guide is for quick reference only. Refer to RXPW4 installation and operating instructions for further information 1 - Time 2 - Day of the week 3 - Current mode 4 - Zone status reference 5 - Controller setup/override buttons 6 - Validation button 7 - Holiday mode 8 - Selector switch index mark 9 - Mode selector switch Symbol Function Continuous comfort (all zones) AUTO Auto mode (heating runs to the preset program for each zone) Continuous set back (all zones) Continuous frost protection (all zones) Set the time Off (no heat output) Heater mode configuration PROG Set the daily programs Mode Selector Functions The RXPW4 controller allows control of multiple Dimplex heaters from a single point. Heaters can be grouped together in “zones” and each zone configured with a different time program for each day of the week. Up to 4 zones are available. Before the controller can be programmed, it is first necessary to set the current time and day of the week. 1. Turn the mode selector switch to the position. 2. Use the “+” and “-” buttons to cycle through the hours/ days of the week until the correct time/day is set. 3. Press OK to confirm. Note: Typically 1 = Sunday, 2 = Monday, etc. Setting the daily program for each zone 1. Turn the mode selector switch to the PROG position. 2. Use the “+” and “-” buttons to select the zone you wish to programme (e.g. P=1). 3. Press OK to select. 4. Use the “+” or “-” buttons to set the program for each hour of day 1 (i.e. Sunday). 5. “+”sets an hour of Comfort (on) and “-” sets an hour of Background (off). The hours of the day are denoted across the bottom of the display. 6. Press OK to confirm when the program has been set. The programme for day 2, etc. can then be set in the same way.. 7. To copy the program from one day to the next, hold down the OK button for 5 seconds. Setting the daily program for each zone (cont.) 8. Once the daily programs have been set for Zone 1, repeat the process for Zones 2 - 4. 9. To run the program, set the mode selector switch to the AUTO position. 10. The status of each zone is indicated on the display (1 bar = background (off), 4 bars = Comfort (on). Temporarily over riding the the daily program When the programmer is in AUTO mode, the current setting for each zone can be temporarily over ridden (advanced). 1. Press the OK button. The bars above Z1 will flash. 2. To change the status of zone 1 (e.g. from Comfort to Back- ground), press the “+” or “-” button, followed by OK to confirm. 3. Alternatively, to change the status of a different zone, press the OK button until the bars above the required zone flash and repeat the steps above to change the status. 4. This will temporarily over ride the program until the next scheduled status change. Manual over ride (all zones) To permanently over ride the mode of all zones, turn the mode selector switch to one of the manual setting positions: COMFORT (ON) mode BACKGROUND (OFF) mode FROST PROTECTION mode STANDBY mode Please refer to the individual heater instructions to details of heater operation in each mode Glen Dimplex UK Ltd. Millbrook House, Hedge End, Southampton, SO30 2DF. For further assistance please contact Dimplex customer services on 0870 727 0101
Reference Book (190x5, #E93P98)
190x5, 94, philips/190x5.pdf
#26F184: WRTR-262GN User Guide
WRTR-262GN, 13, gemtek-systems/wrtr-262gn.pdf
#59VOJ3: FD 8502CC Instruction
FD 8502CC, 2, formax/fd-8502cc.pdf
DW 4803 Dishwasher - #G59MGV
DW 4803, 22, zanussi/dw-4803.pdf
BRAVIA 3-298-969-61(1) Flat Panel TV - #895N42
BRAVIA 3-298-969-61(1), 84, sony/bravia-3-298-969-61-1.pdf
Heater User Manual #8W4U57
2E510E, 24, dayton/2e510e.pdf
Block 642189 Ventilation Hood - #3PNQ5K
Block 642189, 2, zanussi/block-642189.pdf
#AN995F: K-575BT User Guide
K-575BT, 16, kenwood/k-575bt.pdf
Wheelchair Traveler L3 Reference Book, #Z5HG7L
Traveler L3, 32, everest-jennings/traveler-l3.pdf
DeLonghi Coffee Grinder Manual (#6EM6K2)
Coffee Grinder, 5, delonghi/coffee-grinder.pdf
Installation InstructionsOriginal InstructionsPowerFlex 70 Adjustable Frequency AC DriveThis document explains the 5 BASIC STEPS to install and perform a Basic Start-up of the PowerFlex® 70 AC drive. A human interface module (HIM) is required to perform the Basic Start-up routine that i ...
Model & Doc Type: PowerFlex 70 50
Pneumatic Control Manual 717.1Receiver-Controllers SectionTechnical Bulletin T-5800-3/-4Issue Date 0586© 1986 Johnson Controls, Inc.1Part No. 24-7029-0, Rev. —Code No. LIT-7171320XT-5800-3 and T-5800-4Dual Input Receiver-ControllersInstallation and CalibrationThe T-5800 Series Receiver-Control ...
Model & Doc Type: T-5800 Series 12
12 The Xbox Guide button in the center of your controller puts the Xbox 360® experience at your ngertips. Press and hold the Xbox Guide button to tur ...
Model & Doc Type: Xbox 360 Universal Media Remote 2
Translated by R.Whitehead 21-1-2012 for my own use (No liability can be accepted for the result of any errors!) 1 of 4 YGE 200 HV FAI Speed controller for Pylon and Hotliner Technical data: - The max. Full throttle current is 200A for 30 seconds - 4 to 10s LiPo, with low voltage de ...
Model & Doc Type: 200 HV FAI 4
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Lynxspring | JENEsys Edge 534 |
31 | 26/02 | ||
2 | Zapi | SMART CONSOLE |
50 | 16/01 | ||
3 | KMC Controls | BAC-7401 |
18 | 20/02 | ||
4 | Love Controls | 2600 SERIES |
52 | 13/02 | ||
5 | Omron | NA5-12W series |
156 | 05/01 | ||
6 | SYCLOPE | ODISEA |
33 | 12/12 | ||
7 | RKC INSTRUMENT | THV-1 |
30 | 09/02 | ||
8 | Meridian | 861 |
4 | 05/11 | ||
9 | Flycolor | X-Tower F4 FC |
2 | 10/01 | ||
10 | Cisco | ONS 15454 Series |
62 | 30/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Sony | LMD1541W |
44 | 1.27 Mb | 30.10.2023 | |
2 | Blackberry | 8520 - Curve - T-Mobile |
278 | 2.13 Mb | 09.04.2024 | |
3 | Frigidaire | GLGH1642DS1 |
4 | 0.16 Mb | 26.12.2023 | |
4 | Roland | SRX-08 |
24 | 1.38 Mb | 08.01.2024 | |
5 | Proview | P6NS Series |
46 | 31.03.2024 | ||
6 | Jonsered | HT 2121 |
29 | 02.03.2024 | ||
7 | Nikon | Multizoom AZ100 |
27 | 18.12.2023 | ||
8 | Sunbeam | CKSBSK12B-033 |
16 | 17.10.2023 | ||
9 | Emerson | CK5859 |
2 | 0.13 Mb | 30.11.2023 | |
10 | Oracle | Retail Place 12.2 |
68 | 09.01.2024 |