Specifications:760/760439-1f95w80.pdf file (02 Jan 2024)
|
White Rodgers 1F95W-80 Thermostat PDF Operation Manual (Updated: Tuesday 2nd of January 2024 04:42:10 AM)
Rating: 4.7 (rated by 73 users)
Compatible devices: 1F85RF-275, UNIVERSAL INTEGRATED FURANCE CONTROL 50A65-843, 1F80-240, 1F97W-51, 1F92W-51, F145-1189, 1F92W-71, 1F80-261.
Recommended Documentation:
5, White Rodgers 1F95W-80 5 Before you begin programming your thermo- stat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. The information in this section will help you become familiar with your new thermostat so that you can easily program i…
12, 12 OPERATING FEATURES Now that you are familiar with the thermostat display and buttons, read the following informa- tion to learn about the many features of the thermostat. • COMPUTED ENERGY MANAGEMENT RECOVERY (EMR) — The thermostat’s microcomputer automatically calculates the time …
26, 26 same program you set for Monday. You may also choose to use the HOLD COPY button to copy any day’s heating and cooling program into any other day’s program (see USING THE COPY BUTTON). 8. To enter Tuesday’s through Sunday’s heat- ing programs, use the HOLD COPY button…
8, 8 The Display 1 Continuously displays system mode (HEAT, OFF, COOL, AUTO, HOLD). During pro- gramming, the day of the week is displayed (MO, TU, WE, etc.). 2 Alternately displays room temperature (F denotes degrees Fahrenheit and C denotes degrees Celsius) and time of day (A de- notes AM time…
13, 13 position (see figure below). Remove the battery for at least two minutes, to allow the thermostat to reset itself. Replace the bat- tery and put the thermostat back on the wall. Press SYSTEM HEAT - OFF - COOL - AUTO until the desired operating mode is displayed. EMR (ON) Switch #1 set at inst…
27, 27 Enter Cooling Program If outside temperature is below 50°F, we recommend that you remove the thermo- stat from the wall before proceeding with the following steps to program cooling temperatures. Personal injury or prop- erty damage may occur due to air condi- tioner compressor slugg…
#16M5HB: SUBWOOFERS Instruction
SUBWOOFERS, 28, tannoy/subwoofers.pdf
WST 100 DV Central Vacuum Systems - #4LYD66
WST 100 DV, 26, nilfisk-advance/wst-100-dv.pdf
#87672H: FC-350 Guidance
FC-350, 18, skymsen/fc-350.pdf
FSL3D 3D Printers Manual (#L5VROD)
Phoenix Touch, 45, fsl3d/phoenix-touch.pdf
66874 Tools - #B657C1
66874, 16, central-pneumatic/66874.pdf
Cell Phone Reference Book #664X7E
iPhone 6s Plus, 25, apple/iphone-6s-plus.pdf
Generac Power Systems Switch Manual (#R94JUW)
6294 and, 13, generac-power-systems/6294-and.pdf
Pulnix Document: TM-5LC (#2ZW2F1)
TM-5LC, 19, pulnix/tm-5lc.pdf
Epson Projector Manual (#694T61)
EB-X11, 2, epson/eb-x11.pdf
Financial Manager Calculator - #Y66425
Financial Manager, 29, canon/financial-manager.pdf
manual Webheat Control P30 EN.docx www.webheat.eu Installation & programming manual WebHeat Control P30 The on-wall thermostat P30 is designed to control heating systems, specifically the WebHeat self regulating heating cables. The controller switches on the heating sections when the set te ...
Model & Doc Type: Control P30 4
SET1. DESCRIPTIONThe Microsol SWP Advanced is a differential thermostat for solar heating that controls the water circulation pump based on the temperature differential between the solar collector and the pool or thermal reservoir. The controller has functions to prevent o ...
Model & Doc Type: Microsol SWP Advanced 3
CM700 Wireless Installation GuideCM727 / CM721 Wireless Programmable Room Thermostat & BDR91 Relay boxDescriptionThe Honeywell CM700 Wireless (CM727 or CM721) is a modern wireless programmable room thermostat based on Honeywell’s proven programming philosophy. To further imp ...
Model & Doc Type: CM721 12
Variable Speed Ultra-High SEER Split SystemThese units have been designed and tested for capacity and effi ciency in accordance with ARI standards. These outdoor air conditioning units are de-signed for use exclusively with select NORDYNE G6 gas furnaces and select NORDYNE B5 air handlers equipped ...
Model & Doc Type: iQ Drive 8
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Danfoss | TP9000 |
64 | 06/01 | ||
2 | Braeburn | Premier Series |
9 | 08/12 | ||
3 | Geberit | Bambini 599113000 |
44 | 19/01 | ||
4 | Honeywell | RLV4305 |
40 | 2.75 Mb | 28/10 | |
5 | DELTA DORE | DELTA 8000 MASTER |
11 | 23/11 | ||
6 | Johnson Controls | GLAS |
21 | 13/03 | ||
7 | Sangamo | Choice RSTAT5 RF |
8 | 03/04 | ||
8 | PSG | Accustat Independence ES-H2 |
3 | 07/01 | ||
9 | Honeywell | t8501A |
12 | 08/02 | ||
10 | Uponor | SetPoint 521 |
8 | 02/01 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Ryobi | RY09465 |
48 | 7.07 Mb | 29.10.2023 | |
2 | Spring | Raclette8 |
51 | 21.04.2024 | ||
3 | Sandstrom | S02AT10 |
2 | 12.04.2024 | ||
4 | Timex | t226 |
8 | 18.12.2023 | ||
5 | Harbor Freight Tools | 65159 |
18 | 0.67 Mb | 06.02.2024 | |
6 | Legacy | LXR-3A |
12 | 23.03.2024 | ||
7 | Triax | ST-HD 537 |
36 | 5.38 Mb | 15.12.2023 | |
8 | Cisco | SD2008T-NA |
46 | 1.08 Mb | 14.01.2024 | |
9 | Kontron Embedded Computers | PCI-760 |
84 | 22.02.2024 | ||
10 | Radionics | 4112-636 |
27 | 13.12.2023 |