Specifications:866/866328-super_800_series.pdf file (17 Oct 2023)
|
Toro Super 800 Series Irrigation System PDF Installation Instructions (Updated: Tuesday 17th of October 2023 10:04:48 AM)
Rating: 4.6 (rated by 23 users)
Compatible devices: NO FOUND TMC-424E, TMC-424, TR70XT SERIES, 34XX-10-XX, MULTIMATIX 720G, 340 Series, ZSERIES 570Z, 53763.
Recommended Documentation:
The Super 800 Rotor is designed for residential and light commercial installations. It is ideal for medium turf applications where heads are spaced from 30'–40' (9–12 m) on center. Features: Nozzling Up The System A 2.5 GPM nozzle comes pre-installed from the factory. A nozzle tree consisting of eight additional nozzles is provided with each rotor ( Figure 1). Please see the nozzle performance chart for flow rates. By using various combinations of nozzle flow rates and arcs, you can balance the sprinklers to achieve approximately the same precipitation rates. Every case of product contains two Super 800 rotor keys ( Figure 1). The Super 800 key is used to pull up the riser, to remove the nozzle, to reduce the radius and to adjust the arc ( Figure 2). Each use is described in the following instructions. To Insert/Extract A Nozzle Use the winged portion of the key to pull up the riser on the pop up version to access the nozzle orifice. Insert the key into the pull-up hole ( Figure 3), turn it 90 °, and pull up. Hold the riser in the pulled-up position. Using the end of the key, turn the radius adjustment screw counterclockwise until it clears the top of the nozzle ( Figure 4a). To remove the nozzle, insert the key into the slot at the top of the nozzle, above the nozzle number. Exert pressure laterally while pulling on the key to dislodge and remove the nozzle ( Figure 4b). To install a nozzle, press the nozzle into the nozzle socket. The nozzle number should be visible and the nozzle prongs should be at 12 o’clock. Turn the radius adjustment screw clockwise to its desired location ( Figure 5) ensuring that it is in a position to hold the nozzle in place even if radius reduction is not required. Nozzle Performance Chart For Product Inquiries: The Toro Company 5825 Jasmine Street Riverside, CA 92502-0489 Tel: (909) 688-9221 (800) 225-2839 To Set The Arc The rotor is pre-set from the factory at 90°. The Super 800 rotor has a fixed LEFT stop. To find the left stop position, rotate the nozzle turret clockwise (to the right) until it stops, then rotate the nozzle turret all the way back to the left. To increase the arc, insert the key into the arc adjustment slot, indicated by an arrow in the center of the turret. Hold the turret in place while turning the tool clockwise. Keep turning until the arrow points to the desired arc. The arrow will point to the adjustable right stop. See Figure 6. When the rotor is set at 360 °, it will continuously rotate in a clockwise direction. To decrease the arc, insert the key into the arc adjustment slot. Hold the turret in place while turning the tool counter clockwise. Keep turning until the arrow points to the desired arc. The arrow will point to the adjustable right stop. To adjust the arc while the rotor is running, turn the turret gently in the direction that it is spraying. Once the left stop has been located, follow the directions above to increase or decrease the arc. To line up the left stop with landscape features which define the left side of the irrigated arc, simply turn the pop up housing or the shrub base and point the left stop where the sprinkler should start spraying. You may also pull the pop up riser up with the key and rotate the LOWER part of the riser until the left stop is at the desired left stop position. DO NOT rotate the TOP part of the riser. Installation Tips The pop up version should be installed with the cap at the finished grade ( Figure 7). It is not designed to be installed below grade. The shrub version is mounted above grade. The radius adjustment screw can be used to reduce the radius of throw by up to 25%. You should note that this does not reduce the flow of the nozzle. The screen can be accessed through the bottom of the riser. Remove the cap of the pop up version and lift the riser assembly out of the housing can. The shrub version can be unscrewed from the base. If plugged, the screen can be removed, cleaned, and re-inserted into the riser. The Super 800 rotor has a universal stator which eliminates the need to regulate the flow regardless of the nozzle used. There is a pre-installed check valve on the Super 800 rotor. Use of the check valve will eliminate low head drainage after the zone has run. • Three Body Styles: 5" Pop Up, 12" Pop Up, & Shrub Version • Top Arc Indicator for Visual Adjustment • Slip Clutch • Smart Arc TM • 9 Interchangeable, Reusable Nozzles • Part/Full Circle in One Head • Pre-installed Check Valve • Universal Stator • Standard Rubber Cover • Single Bore Orifice Prevents Clogging • Heavy Duty Retract Spring • Pressure Activated Seal • Heavy Duty Plastic Construction • Robust Trip Mechanism Pressure PSI 30 40 Nozzle Number .50 .75 1 2 2.5 3 4 6 8 .50 .75 1 2 2.5 3 4 6 8 Radius Ft. 28 29 32 37 38 38 43 45 42 29 30 33 40 39 39 44 46 45 Flow GPM 0.5 0.7 1.3 2.4 2.5 3.6 4.4 5.9 8.0 0.6 0.8 1.5 2.5 2.8 4.2 5.1 6.0 8.5 Pressure PSI 50 60 Nozzle Number .50 .75 1 2 2.5 3 4 6 8 .50 .75 1 2 2.5 3 4 6 8 Radius Ft. 29 31 34 42 40 41 46 48 49 30 32 35 43 41 42 49 49 50 Flow GPM 0.7 0.9 1.6 3.0 3.2 4.6 5.6 6.3 9.5 0.8 1.0 1.8 3.3 3.5 5.0 5.9 6.7 10.0 Nozzle Tree P/N 102-1992 Super 800 Rotor Key P/N 102-1889 Radius Adjustment / Nozzle Retention Screw Arc Adjustment Dial Pull-Up Keyhole Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 © 2003 The Toro Company Form Number 373-0152 Rev. B a Shrub Rotor 5" Rotor 12" Rotor Figure 7Figure 6 Left Stop Fixed-Stop Right Stop Adjustable Stop-Return Point Super 800 Series Sprinklers Installation Instructions b Pointed Tip For Extracting Nozzles
LTG-2100T Toy - #I46Y96
LTG-2100T, 22, logitech/ltg-2100t.pdf
Robur Boiler Manual (#TISLIK)
AY00-120, 64, robur/ay00-120.pdf
TESTO User Manual Thermometer 104 (#98R8H5)
104, 8, testo/104.pdf
Multi-Power Portable Generator Manual (#7PU7X9)
MP7500E, 35, multi-power/mp7500e.pdf
Instruction (Signage Solutions E-Line Display BDL5551EL/00, #Y1KIIS)
Signage Solutions E-Line Display BDL5551EL/00, 39, philips/signage-solutions-e-line-display-bdl5551el-00.pdf
HC-X920 Camcorder - #51H93J
HC-X920, 28, panasonic/hc-x920.pdf
Sennheiser Document Other EW 114 G3 - FREQUENCY SHEETS (#QLD87H)
EW 114 G3 - FREQUENCY SHEETS, 4, sennheiser/ew-114-g3-frequency-sheets.pdf
GSK Controller Manual (#TCT9JC)
988T, 216, gsk/988t.pdf
Motorola Processor Manual (#5WMH81)
DSP56000, 596, motorola/dsp56000.pdf
#A59J11: ForteRAID User Manual
ForteRAID, 20, glyph/forteraid.pdf
Model LD — 11.2 K-factor Large Drop Upright Sprinkler, Standard Response Control Mode Specific ApplicationPage 1 of 4 AUGUST 2018 TFP335IMPORTANTRefer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information.Always refer to Technical Data Sheet TFP ...
Model & Doc Type: tyco LD 4
MICROFAST® QUICK RESPONSE FUSIBLE ELEMENT CONVENTIONAL SPRINKLER VK311 (K5.6)TECHNICAL DATAPage 1 of 3The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: [email protected] ...
Model & Doc Type: MICROFAST VK311 8
Omega HEC-12ProductDescriptionThe Omega Model HEC-12sprinkler is an extremely versatilehorizontal sidewall sprinkler. It is alow profile, aesthetically pleasing,wall mounted sprinkler that operatesfive to six times faster than astandard sprinkler. It offers a highdegree of protection f ...
Model & Doc Type: CENTRAL Omega HEC-12 4
MODEL M FRAME STYLE SPRAY NOZZLESTECHNICAL DATAThe Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: [email protected] the Viking website for the latest edition of this technical data p ...
Model & Doc Type: M 10
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | K-Rain | PRO-LC |
28 | 08/02 | ||
2 | Toro | EVOLUTION Series |
16 | 09/03 | ||
3 | Toro | MultiStream 53246 |
4 | 28/03 | ||
4 | Tyco Fire Product | Star LD-2 |
4 | 23/01 | ||
5 | Toro | MULTIMATIX 720G |
2 | 16/10 | ||
6 | Toro | TMC-424 |
1 | 0.25 Mb | 04/03 | |
7 | Tyco Fire Product | CENTRAL Omega HEC-12EC PRO |
4 | 07/01 | ||
8 | Tyco Fire Product | Star E |
4 | 21/02 | ||
9 | Reliable | DH80 Dry |
9 | 23/12 | ||
10 | easymaxx | 03160 |
4 | 01/12 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Dynex | DX-M102 |
16 | 0.9 Mb | 28.12.2023 | |
2 | CABASSE | ARCHIPEL 17ICPS |
2 | 1.76 Mb | 09.12.2023 | |
3 | Samsung | SH-S183A |
1 | 0.27 Mb | 18.01.2024 | |
4 | Carrier | CDT-105E3 |
7 | 09.03.2024 | ||
5 | Panasonic | KX-TG5779 |
15 | 0.75 Mb | 02.03.2024 | |
6 | Hunter | 80206 |
20 | 25.10.2023 | ||
7 | RME Audio | ADI-2 |
17 | 0.25 Mb | 17.12.2023 | |
8 | Everpure | EV9006-00 |
2 | 0.59 Mb | 01.02.2024 | |
9 | Trianco | EuroStar WM 50 |
32 | 24.12.2023 | ||
10 | Pentax | 70 |
36 | 0.88 Mb | 06.12.2023 |