Compatible devices: 840080, 850004, AquaShock 850046K, 840081, 850014, 850097, 850071, 840021.
Recommended Documentation:
2, - 2 - Microwave Meter 840046 Copyright ©2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. …
3, - 3 - TABLE OF CONTENTS INTRODUCTION. . . . . . . . . . . . . . . FEATURES . . . . . . . . . . . . . . . . . . . MATERIALS SUPPLIED. . . . . . . . . KEYPAD. . . . . . . . . . . . . . . . . . . . . . MEASUREMENT PROCEDURES. . BATTERY REPLACEMENT. . . . . . . MAINTENANCE. . . . . . . . . . . . . . . . OPTIONAL ACCESSORIES. . . . . . SPECIFICATIONS. . . . . . . . . . . . . . WARRANTY . . . . . . . . . . . . . . . . . . 4 5 6 7 8 16 16 17 18 20 …
4, - 4 - INTRODUCTION Measure hazardous microwave oven leakage With use microwave oven door seals may wear enabling hazardous microwaves to leak out. Sper Scientific Microwave Meter is calibrated at 2.45 GHZ, the precise frequency of microwave ovens to accurately measure the intensity of such micro- wave leakage. Features maximum and minimum hold, an audible alarm, and a zero adjustment to eliminate background EMF. The display also indicates overload and low battery. Com…
5, Sper scientific 840046 - 5 - FEATURES Frequency selection of normal or microwave range Tripod mounting socket Maximum and minimum Hold function Auto-power-off Built-in alarm Zero offset adjustment Overload indicator Low battery indicator …
6, - 6 - MATERIALS SUPPLIED Meter 9 Volt Battery Instruction Manual Soft Carrying Case …
7, - 7 - KEYPAD 1. Sensor position 2. LCD 3. Zero button 4. Power on/off 5. Maximum/minimum button 6. Frequency range selection button 7. Data hold button 8. Tripod mounting socket 9. Battery cover …
8, Sper scientific 840046 MEASUREMENT PROCEDURES 1. Press POWER to turn the meter on. 2. Press FREQ. RANGE to select microwave (2.45 GHZ) or RF (50 MHZ to 3.5 GHZ). When 2.45 GHZ is selected, “2450 MHZ” will appear on the lower right corner of the LCD. When normal range is selected, “2450 MHZ” will disappear from the lower right corner of the display. 3. For general information on microwave oven leakage and instructions on preparing for microwave measurement, see page 14. 4. Position the top of the…
9, - 9 - Measurement Position Figure 1 shows the correct measurement position of RF electromagnetic field strength. Figure 2 shows the incorrect measurement positions of RF electromagnetic field strength. MEASUREMENT PROCEDURES Figure 1 Figure 2 …
10, - 10 - Note… Due to background environmental magnetic fields, this meter may display a reading value under 0.002 mW/cm 2 prior to measuring. Maximum, Minimum and Hold 1. Press MAX/MIN to retain the maxi- mum value. “MAX” will appear on the LCD. The meter will continue measuring, holding the maximum value on the LCD until exceeded. 2. Press MAX/MIN again to retain the minimum value. “MIN” will appear on the LCD. The meter will…
11, Sper scientific 840046 - 11 - flash on the LCD. The meter will continue measuring, holding the maximum and minimum values on the LCD until exceeded. 4. Press and hold MAX/MIN for more than one second to exit and return to Normal Mode. 5. Press HOLD to freeze the current value on the display. “DH” (Data Hold) will appear on the LCD. Press HOLD again to release the data hold. Auto Power Off 1. To save battery life, the meter will automatically turn off after 30 minutes of inactivity. To disable this function: MEASUREMEN…
12, Sper scientific 840046 - 12 - 2. Press POWER to turn the meter off. Press and hold MAX/MIN while simultaneously pressing POWER to turn the meter on. Auto-power-off is now disabled. 3. To restore auto-power-off: Press POWER to turn the meter off and then press POWER again to turn the meter back on. will appear on the LCD to indicate that auto-power-off is enabled. Alarm The meter features a built-in alarm that will sound when the measurement exceeds 1 mW/cm 2 . The…
13, Sper scientific 840046 - 13 - MEASUREMENT PROCEDURES Zero Offset Adjustment If the meter shows a measurement other than 0 due to background EMF, zero adjusting will eliminate this electromagnetic interference. Press ZERO to adjust and obtain a 0 measurement. “ZERO” will appear on the LCD. Overload Indicator When the reading exceeds 4 mW/cm 2 , “OL” will appear on the LCD to indicate overload. Low Battery Indicator The symbol will appear on the LCD to indicate …
14, - 14 - Microwave Oven Leakage With time, microwave leakage around door seals, hinges and metal fittings is not uncommon. Therefore, it is important that all microwave ovens be periodically checked to ensure that no damage or malfunction has occurred. Microwaves may easily pass through porcelain, glass, ceramics and most plastics. Highly potent microwave energy generated by microwave ovens is also capable of penetrating living tissue to a depth of approxim…
15, - 15 - 1. Because microwave ovens should not be operated while empty, fill a microwave safe container with 275 ml of water and place it in the center of the oven during testing. 2. Start the microwave at maximum power. 3. Follow the measurement procedures on page 8, concentrating measurements on door seams, window seals, welds and rivets. MEASUREMENT PROCEDURES …
16, - 16 - BATTERY REPLACEMENT 1. Press POWER to turn the meter off. 2. Remove the battery cover on the back of the meter. 3. Remove the old battery and replace with 1 new 9V battery, ensuring correct polarity. 4. Replace the battery cover. MAINTENANCE Use a soft, dry cloth to clean the meter. Do NOT use a wet cloth, solvents, water or any liquid to clean the meter. …
17, - 17 - 840090 Water Resistant Instrument Pouch 840093 Field Tripod 850000 Rubber Boot OPTIONAL ACCESSORIES …
18, - 18 - SPECIFICATIONS Accuracy ± 2 dB at 2.45 GHZ ± 50 MHZ Resolution 0.001 mW/cm 2 Display 3 3/4 digits LCD; maximum reading 3999 (4 mW/cm 2 ) RF Frequency 50 MHZ to 3.5 GHZ Axis Single Sample Rate 2.5 times per second Operating Temperature & Humidity 5°C to 40°C ˂80% RH RF Power Density 0.003 to 2.700 m W/cm 2 Microwave Frequency 2450 MHZ …
19, Sper scientific 840046 - 19 - Storage Temperature & Humidity -10°C to 60°C ˂70% RH Operating Altitude ≤ 2000 M Operating Environment Indoor use; pollution degree 2* Battery 9V NEDA 1604, IEC 6F22 or JIS 006P Battery Life Approximately 100 hours Dimensions 5 ¼” x 2 ¼” X 1 ¼” (130 x 56 x 38 mm) Weight 6 oz (170 g) SPECIFICATIONS *Pollution degree is a classification of the amount of dry pollution and condensation present in an environment. This classification affects clearance distances required for …
20, - 20 - WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the …
5XP-A Multimeter - #3TU4X2
5XP-A, 6, amprobe/5xp-a.pdf
Fisher & Paykel Document: DD24DCT (#1M47UN)
DD24DCT, 2, fisher-paykel/dd24dct.pdf
Control Unit Guidance #P96TO6
XIOS XG, 80, sirona/xios-xg.pdf
Surge Protector AVR 1500/SIV Guide, #LFAANX
AVR 1500/SIV, 10, powerwalker/avr-1500siv.pdf
Reference Book (Dual WAN VPN Firewall VPN 3000, #639CL7)
Dual WAN VPN Firewall VPN 3000, 76, basewall/dual-wan-vpn-firewall-vpn-3000.pdf
Kitchen Appliances 8118 Guide, #M5Q26Z
8118, 2, coopers/8118.pdf
APM POWER METER EN: Before installation, read the Safety Warnings overleaf. CAUTION: Risk of Danger Read complete instructions prior to installation and operation of the unit CAUTION: Risk of electric shock EN Intended Use: The APM has been specifically designed for engineers requiring an effective way to monitor and display data. The APM accepts a range of electrical inputs (dependin ...
APM 3
FieldpieceStatic Pressure ProbesModel: ASP2OPERATOR’S MANUALDescriptionUse your ASP2 Static Pressure Probes to meas-ure duct static pressure the right way. Slide yourASP2 into the rubber hose of Fieldpiece modelsAMN2, ADMN2, SDMN5, or any manometer withappropriate sized ports, to greatly improve accura-cy over using the hose alone. Designed for HVAC/Rtechs ...
ASP2 2
P/N UMADULTHR Rev20141016_web Model Number: ADULTHR Height Measuring Rod USER INSTRUCTIONS Thank you for your purchase of this Health o meter® Professional product. Please read this manual To avoid damaging when unpacking, do not use a box cutter, knife, scissors or any sharp object when opening the protective inner packaging. The following information details what you ...
Health o meter Professional ADULTHR 8
INSTRUCTION MANUALHI774 Phosphate Ultra Low RangeReagent SetsHI774-25 Reagents for 25 Phosphate Ultra Low Range testsOther AccessoriesHI774-11 Phosphate Ultra Low Range Certified Standard KitHI731318 Cloth for wiping cuvettes (4 pcs.)HI731315 Glass Cuvettes and Caps for Checker® HC Colorimeters (2 pcs.)HI731353 Cuvette Seal Cap for Checker® HC Colorimeters (4 pcs.)HI74002 ...
HI774 2
The Home ScreenThe Home screen displays total ow volume and ow rate. The four buttons below the LCD display are used to access menu screens for viewing and changing setup parameters. Press the check mark key to enter a submenu.The left/right keys are used to move through the menus and position the cursor during data entry. The up arrow is used to scr ...
FT430 2
INST No INE-403-0P0 IR-M2□□□ Series INFRARED MOISTURE METERDESIGNED AS A FIBER OPTIC(Model : IR-M21□□,IR-M22□□) Please be sure to deliver these instructions with the unit to the end user. Always keep these instruction with the unit. ...
IR-M22 SERIES 50
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | FOBO | Tire Plus |
36 | 30/10 | ||
2 | Siemens | 6GA7202-2AA10-1BF1 |
168 | 19/06 | ||
3 | Brüel & Kjær Vibro | DS821 Series |
126 | 31/05 | ||
4 | Suez | Sievers UPW Boron Analyzer |
104 | 30/08 | ||
5 | Desco | 19258 |
6 | 04/06 | ||
6 | BRUEL & KJAER | 4152 |
27 | 16/08 | ||
7 | LogTag | UTRED30-16 |
9 | 30/08 | ||
8 | Colnatec | Eon-LT |
30 | 17/11 | ||
9 | Felix Instruments | F-920 |
51 | 04/10 | ||
10 | Graco | Series D |
16 | 07/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | KitchenAid | 2210725 |
16 | 13.11.2023 | ||
2 | TurboChef | Tornado |
2 | 20.07.2023 | ||
3 | Rath | SmartRescue 5 |
14 | 01.06.2023 | ||
4 | AUDIOLINE | FF 788 |
9 | 1.06 Mb | 02.07.2023 | |
5 | Energizer | CHDC8 |
1 | 0.12 Mb | 19.08.2023 | |
6 | Aeon | New Sporty 125 |
93 | 10.67 Mb | 04.06.2023 | |
7 | Lucent Technologies | INDeX 2010 |
2 | 20.06.2023 | ||
8 | Tenda | W150M |
2 | 0.8 Mb | 09.11.2023 |