Specifications:847/847184-pf2a3_series.pdf file (03 Oct 2023)
|
SMC Networks PF2A3 Series Measuring Instruments PDF Operation Manual (Updated: Tuesday 3rd of October 2023 01:29:20 PM)
Rating: 4.8 (rated by 75 users)
Compatible devices: PPA Series, ZSE30AF series, G46-L Series, ML2B Series, PPA100 Series, PFG3 0 Series, IZH10, PFM3 Series.
Recommended Documentation:
Flow Monitor Operation Manual PF2A3 /PF2W3 /PF2D3 Installation •Never mount the product in a location that will be used as a foothold. Thank you for purchasing an SMC PF2A3 /PF2W3 /PF2D3 Series Flow Monitor. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference. To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www.smcwo rld. com ) or contact SMC directly. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are a llowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product. Caution: Warning: Danger: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Safety Instructions Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate in an atmosphere containing flammable, explosive or corrosive gas. Fire or an explosion can result. This product is not designed to be explosion proof. Do not touch the piping or its connected parts when the fluid is at high temperature. It may lead to burnt. Ensure the piping cools sufficiently before touching. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit: •Provide a double interlocking system, for example a mechanical system •Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. The following instructions must be followed during maintenance: •Turn off the power supply •Ensure the flow is shut off before performing maintenance Otherwise an injury can result. After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty. Disconnect the power supply and stop the fluid supply. Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction. Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. D o not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Warning Caution Maintenance How to reset the product after a power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing. The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment. Therefore, check the safety of the whole installation before operating the product. Summary of Product parts Mounting and Installation Indicator LED (OUT1) b utton (UP) LED display Panel mount adapter b utton (SET) Indicator LED (OUT2) button (DOWN) Indicator LED Item Installing Removing the panel mount adapter •Remove the panel mount adapter from the product if it has been delivered assembled. •Remove the mounting bracket using a flat blade screwdriver. Hook •Lever the hook to the outside to remove the adapter (See below). •If the panel mount adapter is pulled with the hook engaged, the product or the panel mount adapter will be damaged. Front Description Terminal block T erminals to connect the power, output and sensor wires. For details, refer to Wiring. Terminal block Item Back Description LED display Displays the flow value, setting mode, and error indication. Indicator LED I ndicates the reference condition selected. LED is ON (Red) when normal condition is selected. (Only the PF2A3 ) P anel mount adapter Adapter to mount the product to the panel. Indicator LED (OUT1) Indicates the output status of OUT1. LED is ON (Green) when OUT1 is ON. The LED flashes when an over current error occurs. W hen the accumulated pulse output mode is selected, the indicator LED will turn OFF. Indicator LED (OUT2) I ndicates the output status of OUT2. LED is ON (Red) when OUT2 is ON. T he LED flashes when an over current error occurs. When the accumulated pulse output mode is selected, the indicator LED will turn OFF. button (UP) Selects the mode or increases the ON/OFF Set value. button (SET) Press this button to change to another mode and to set a value. button (DOWN) Selects the mode or decreases the ON/OFF Set value. + PF2A30 series PF2A550PF2A510 P F2W511 PF2D520 PF2D540PF2D504 Connected sensor Display instantaneous flow → ← Display accumulated flow 2 sec. 2 sec. or longer Display mode Display accumulated flow Display instantaneous flow 3 sec. or longer 3 sec. or longer I nput the Set value of instantaneous output (Auto-preset) I nput the Set value of accumulated output I nput the Set value of instantaneous output Input of the Set point 1 (OUT1) Input of the Set point 2 (OUT1) Input of the Set point 3 (OUT2) Measurement of the Set value (OUT1) Input of the Set value for the lower 3 digits (OUT1) I nput of the Set value for the u pper 3 digits (OUT1) Input of the Set value for the lower 3 digits (OUT2) Input of the Set value for the upper 3 digits (OUT2) Function selection mode Measurement of the Set value (OUT2) F low Set value is calculated and set. Flow Set value is calculated and set. Display instantaneous flow →← Display accumulated flow D isplay accumulated flow Accumulated value is reset Display instantaneous flow Display upper 3 digits Accumulated output mode Accumulated pulse output mode Instantaneous output mode Output mode (OUT1) Accumulated output mode Accumulated pulse output mode Instantaneous output mode Output mode (OUT2) Unit selection function ∗ 1 L/min,L Non-Reverse output Reverse output Switch operation (OUT2) Non-Reverse output Reverse output Normal condition Standard condition 標準状態 Reference condition ∗ 2 CFM x 10 -2 , CFM x 10 -1 , ft 3 x 10 -1 , gal(US)/min, gal(US) Indicator LED Switch operation (OUT1) Measurement mode (Instantaneous flow) ∗ : Start the setting here to supply power under the default settings. Measurement mode (Accumulated flow) Accumulation stop Accumulation starts Press and PF2A511 PF2A521 PF2A551 PF2A31 series PF2W520 PF2W540PF2W504 P F2W30 series P F2W33 series PF2D30 series 2 sec. ∗ 4 Set valueor ∗ 3 ∗ 4 Set value or ∗ 3 ∗ 4 ∗ 4 ∗ 4 Set value Set value Set value or ∗ 3 ∗ 4 Set value or ∗ 3 ∗ 4 Set valueor ∗ 3 ∗ 4 Set value or ∗ 3 ∗ 4 Set value or ∗ 3 ∗ 4 Set value or ∗ 3 U nlock Lock Unlock Lock K ey-lock function Initialize mode Key-lock function ∗ 1: Operate only the product with unit selction function (Model indication: without M). ∗ 2: Operate only the PF2A3 series. ∗ 3: Depend on the setting of switch operation in initialize mode. ∗ 4: Displayed in turn. Input of the Set point 4 (OUT2) ∗ : Accumulation starts and “ - ” flashes. List of outputs Find the diagram of the output required in the table below. Perform settings f ollowing the Set value column on the right. Characters in ( ) are for OUT2. Setting flow chart Flow has exceeded the upper limit of the display flow range. Reduce the flow. Error type Troubleshooting method Error indication The switch output load current is more than 80 mA (OUT1). Turn the power off and remove the cause of the over current. Then turn the power on again. The switch output load current is more than 80 mA (OUT2). The display flow range of accumulated flow has been exceeded. To reset, press and buttons simultaneously for 2 seconds or longer. Then set all data again. The set data has been changed unexpectedly. To reset the accumulated flow value, press and buttons simultaneously for 2 seconds or longer. Key-lock function This function is used to prevent errors occurring due to unintentional changes of the set values. Excessive instantaneous flow Error name OUT1 over current error OUT2 over current error Excessive accumulated flow System error Initialize mode Default settings The default settings are as follows. If this condition is acceptable, then keep these settings. [F_1] Input the Set value of instantaneous output [n_1] Input of the Set point 1 (OUT1) Function selection mode Item ∗ Default settings The default settings are as follows. If this condition is acceptable, then keep these settings. [n_2] Input of the Set point 2 (OUT1) [n_3] Input of the Set point 3 (OUT2) [n_4] Input of the Set point 4 (OUT2) [F_2] Input the Set value of i nstantaneous output (Auto-preset) - [F_3] Input the Set value of accumulated output [1nL] Input of the Set value for the lower 3 digits (OUT1) [ 1nH ] Input of the Set value for the upper 3 digits (OUT1) ∗: When Non-Reverse output is selected as the switching operation, n becomes P. In measurement mode, press the button, to display [F_ ]. This [F_ ] indicates the mode for changing each functional setting. ∗: When OUT1 or OUT2 is assigned to be instantaneous output mode during initialize mode, [F_1] and [F_2] are displayed. When OUT1 or OUT2 is assigned to be accumulated output mode, [F_3] is displayed. 50% of max. rated flow Default setting 50% of max. rated flow 50% of max. rated flow 50% of max. rated flow - [ 0] [ 0] [ 2nL] Input of the Set value for the lower 3 digits (OUT2) [ 2nH ] Input of the Set value for the upper 3 digits (OUT2) [ 0] [ 0] Items below can be set. •Connected sensor •Display mode •Unit selection function ∗ •Output mode (OUT1) •Output mode (OUT2) •Switch operation (OUT1) •Switch operation (OUT2) •Reference condition Troubleshooting Mounting with the panel mount adapter •Install the product as shown below. •Insert panel mount adapter B into section A of panel mount adapter A. Push panel mount adapter B from behind until the display is fixed onto the panel. The pin of panel mount adapter B engages the notched part of panel adapter section A to fix the display. Panel mount adapter A A Panel Panel mount adapter B Press Insert Mounting bracket Wiring •Connections should only be made with the power supply turned off. •Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise. •Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met. This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch- mode power supply and the product, or by using a series power supply instead of a switch-mode power supply. Connecting the wiring •Use suitable crimp terminals for connection to the terminal block. •Attention should be paid to the terminals to avoid short circuits. 1234 5678 Terminal block number 3 5 2 1 4 DC( - ) (for sensor) Sensor input N .C. DC( - ) (supply voltage) D C(+) (for sensor) 6 8 7 DC(+) (supply voltage) OUT1 OUT2 Power is supplied Outline of setting The output will not operate for 3 seconds after supplying power. The identification code of the product is displayed. Measurement mode The mode in which the flow is detected and displayed, and the switch function is operating. This is the basic operating mode; and other modes should be selected for setting changes and other function settings. Initialize mode Function selection mode Key-lock function button press for 2 sec. button press. button press for 3 sec. Instantaneous flow Switch output diagram Output mode Switch operation Set value Instantaneous output mode () Non-Reverse o utput () Set point 2 Set point 1 () H ysteresis mode ∗2 Set point 1 Set point 2 () Window comparator mode S et point 1 Set point 2 () W indow comparator mode Reverse output () O FF ON H ysteresis P_2 ( P_4) P_1 ( P_3) Instantaneous f low OFF ON Hysteresis ∗1Hysteresis ∗1 P_1 (P_3) P_2 (P_4) Instantaneous flow OFF ON Hysteresis n _2 (n_4) n _1 (n_3) I nstantaneous flow OFF ON Hysteresis ∗1Hysteresis ∗1 n_1 (n_3) n_2 (n_4) Instantaneous flow Set point 2 Set point 1 () Hysteresis mode ∗2 Accumulated flow Accumulated output mode () Non-Reverse output () U pper 3 digits Lower 3 digits + ( + ) Upper 3 digits Lower 3 digits + ( + ) Reverse output () OFF ON T ime Time Accumlated flow 1PH+1PL (2PH+2PL) OFF O N Time Time Accumlated flow 1nH+1nL (2nH+2nL) Accumulated pulse Accumulated pulse output mode () N o Set value input No Set value input Reverse output () OFF O N Time 50 ms OFF O N Time 5 0 ms Error display Accumulated flow displayed (flashing) ∗: If the error cannot be reset after the above measures are taken, then please contact SMC. Specification / Outline with Dimensions Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about product specifications and outline dimensions in detail. Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2011 SMC Corporation All Rights Reserved Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyod a-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 URL http://www.smcworld.com Non-Reverse o utput () Refer to the SMC website (URL http://www.smcworld.com) for more information about troubleshooting. ∗1: In window comparator mode, the hysteresis is fixed at 3 digits. When setting, allow 7 digits or more between Set point 1 and Set point 2 (Set point 3 and Set point 4). ∗2: When Set point 1 = Set point 2 (Set point 3 = Set point 4), chattering may occur. Selection of display mode [ d_1 ] Display instantaneous flow I tem D efault settings Unit selection function ∗ [ U_1 ] L/min S election of output mode (OUT1) [ o 10 ] Instantaneous output mode Selection of output mode (OUT2) [ o20 ] Instantaneous output mode Selection of switch operation (OUT1) [ 1_n ] Reverse output Selection of switch operation (OUT2) [ 2_n ] Reverse output Selection of reference condition [Anr] Standard condition S election of the connected sensor [ 10L ] 1 to 10 L/min type (PF2A510) [ 04L ] 0.5 to 4 L/min type (PF2W504) [ 04d ] 0.4 to 4 L/min type (PF2D504) Common M odel Common C ommon Common Common Common P F2A3 series only PF2A30 series PF2W30 series [ 11L ] 10 to 100 L/min type (PF2A511) [ 11L ] 10 to 100 L/min type (PF2W511) PF2A31 series PF2W33 series PF2D3 series Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more detailed information about panel cut-out dimensions. ∗: Operate only the product with unit selection function.
Ikra Handbook Blower KLS 2000 (#U6BQ7L)
KLS 2000, 128, ikra/kls-2000.pdf
Recording Equipment Document #196DY7
MX-505MKIII-2, 48, otari/mx-505mkiii-2.pdf
Keys Fitness User Guide: KPS-LATA (#ZH5DU3)
KPS-LATA, 12, keys-fitness/kps-lata.pdf
Peavey User Manual: E110 (#3S629P)
E110, 28, peavey/e110.pdf
Trimble Measuring Instruments Manual (#BFS1XV)
HL750, 2, trimble/hl750.pdf
Craftsman Trimmer Manual (#WNXMS3)
358.798430, 27, craftsman/358-798430.pdf
#OG2R8Z: MX3710 Guidance
MX3710, 21, memorex/mx3710.pdf
Indoor Furnishing User Manual #I72TX4
Office Stool DC207B, 1, alvin/office-stool-dc207b.pdf
DVP-NS305 DVD Player - #EWRTH9
DVP-NS305, 72, sony/dvp-ns305.pdf
Heater User Manual #L91Y76
KCC SERIES, 4, king-electrical/kcc-series.pdf
55M4000BCE00 REV A 1 Crane safety instrumentation Copyright 2015 (Rayco-Wylie Systems). All rights reserved. Any part of this document may not be reproduced or transmitted in any form or by any means including photocopy or any other information storage and retrieval sy ...
Model & Doc Type: i4000 31
ULTRAPEN™ PT1 Quick Start Guide Conductivity / TDS / Salinity and Temperature Pen PT1QSI 06-18 For a complete set of operating instructions, maintenance procedures, calibration procedures, and the FACTORY CAL reset procedure, download the full PT1 Operation Manual from www.myronl.com. ...
Model & Doc Type: ULTRAPEN PT1 2
ba75719edfs01 05/2007BYKLC3Cat. no.: 1745Operating manualBedienungsanleitungMode d’emploiInstrucciones de operaciónConductivity Pocket MeterPage 3Leitfähigkeits-TaschenmessgerätSeite 17Conductimètres de pochePage 31Medidor manual de la conductividadPágina 45BYKLC3ARS/cmTref25nLF052ARM ...
Model & Doc Type: LC 3 60
GETTING STARTED GUIDENI PXIe-5668R26.5 GHz or 14 GHz Vector Signal AnalyzerNote Before you begin, install and configure your chassis and controller.This document explains how to install, configure, and test the NI 5668R. The NI 5668R is a26.5 GHz or 14 GHz modular vector signal anal ...
Model & Doc Type: PXIe-5668R 30
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | LaMotte | DC1500 |
2 | 11/01 | ||
2 | Draper | PVC150D |
2 | 0.85 Mb | 13/03 | |
3 | Beta industries | Presto BetaColor |
12 | 05/12 | ||
4 | Chauvin Arnoux | PEL 105 |
78 | 26/12 | ||
5 | Simpson | 880 WATTMETER |
19 | 17/10 | ||
6 | Shenzhen 3nh Technology | YG series |
26 | 29/01 | ||
7 | CAPTELEC | M 3530 |
10 | 03/03 | ||
8 | THEIS | DTC 5.1 |
36 | 02/02 | ||
9 | Dräger | X-am 5600 |
304 | 25/02 | ||
10 | Sanyo | MD812 |
2 | 06/01 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | DeWalt | DWV009 |
36 | 13.04.2024 | ||
2 | Omron | S8VK-R Series |
12 | 16.12.2023 | ||
3 | Newcon Optik | NVS 15 |
28 | 06.11.2023 | ||
4 | KitchenAid | KUIS185EBL0 |
11 | 10.03.2024 | ||
5 | Kohler | CH18-CH26 |
246 | 31.12.2023 | ||
6 | Audioplex | VC75 OPTIMATCH |
2 | 0.06 Mb | 10.02.2024 | |
7 | Bravo | IND-2065 |
24 | 23.02.2024 | ||
8 | Axis | JS5001CK |
8 | 22.01.2024 | ||
9 | Yamaha | KMS-1000 |
1 | 29.02.2024 | ||
10 | B&D | Controll-A-Door R |
28 | 14.01.2024 |