Carrier 58DLA Manual, Installation, Start-up, Operating And Service And Maintenance Instructions

Manual, Installation, Start-up, Operating And Service And Maintenance Instructions for Carrier 58DLA Furnace (56 pages)

Specifications:

1237/1237986-58dla.pdf file (29 Feb 2024)
  • Manufacturer: Carrier
  • Category of Device: Furnace
  • Document: 58DLA, File Type: PDF Installation, Start-up, Operating And Service And Maintenance Instructions
  • Updated: 29-02-2024
  • Count of Pages: 56
Download 58DLA Manual (56 pages)

Read PDF Document Online:

Data: UPD 29th February 2024

Carrier 58DLA Furnace PDF Installation, Start-up, Operating And Service And Maintenance Instructions (Updated: Thursday 29th of February 2024 11:06:07 AM)

Rating: 4.6 (rated by 95 users)

Compatible devices: 58 EJB, 58MEC, 58SSC, KGALB0101KIT, DELUXE 58DXC, 110 Series, bryant 915SB, 58PAP.

Recommended Documentation:

Text Version of Carrier 58DLA Furnace Manual (Summary of Contents)

(Ocr-Read of Carrier 58DLA Document (Main Content), UPD: 29 February 2024)
  • 40, 40 Table 12 – Gas Rate (Cu. Ft./Hr.) SECONDS SIZE OF TEST DIAL SECONDS SIZE OF TEST DIAL FOR 1 REVOLUTION 1 Cu Ft. 2CuFt. 5CuFt. FOR 1 REVOLUTION 1CuFt. 2CuFt. 5CuFt. 10 360 720 1800 50 72 144 360 11 327 655 1636 51 71 141 355 12 300 600 1500 52 69 138 346 13 277 555 1385 53 68 136 340 14 257 51…

  • 33, Carrier 58DLA 33 SEE NOTES: 1,2,4,5,6,7,8,9,10 on the page following these figures A03207 Fig. 38 -- Downflow Application--Vent Elbow Left then Up SEE NOTES:1,2,3,4,5,7,8,9 on the page following these figures. A03212 Fig. 39 -- Downflow Application--Vent Elbow Up then Right SEE NOTES: 1,2,4,7,8,9 on the page fol…

  • 49, 49 A91252 Fig. 53 -- Cleaning Heat Exchanger Cell 14. Reinstall internal vent pipe, if applicable. 15. Reinstall vent connector on furnace vent elbow. Securely fasten vent connector to vent elbow with 2 field--supplied, corrosion--resistant, sheet metal screws located 180_ apart. 16. Replace blower…

  • 14, 14 3. Remove bottom closure panel. 4. Reinstall bottom filler panel and screws. Side Return Air Inlet Side Return Air Inlet These furnaces are shipped with bottom closure panel installed in bottom return--air opening. This panel MUST be in place when side return air inlet(s) is used wi…

  • 24, 24 4. Secure field ground wire to green ground screw on J--Box bracket. 5. Connect line voltage leads as shown in Fig. 25. 6. Reinstall cover to J--Box. Do not pinch wires between cover and bracket. 24--V WIRING Make field 24--v connections at the 24--v terminal strip. (See Fig. 23.) Connect…

  • 44, 44 Table 14-- Orifice Size* And Manifold Pressure (In. W.C.) For Gas Input Rate (CONT) (Tabulated Data Based On 21,000 Btuh Per Burner, Derated 4 Percent For Each 1000 Ft. (305 M) Above Sea Level) A10179A To initiate the component test sequence, shut OFF the room thermostat or disconnect the…

DOC-b0f844b6:

Recommended:
Kindle Touch, Paramount 40, T785-R, FA4024CB

G60UH Series, outdoor rooftop gas-fired duct furnace, GHR26 SERIES, 394U, GAS FURNACE 58MXA
  • GAS-FIRED VENTEDGAS-FIRED VENTEDGAS-FIRED VENTEDGAS-FIRED VENTEDGAS-FIRED VENTED W W W W WALL FURNACEALL FURNACEALL FURNACEALL FURNACEALL FURNACEINSTALLATION ANDOPERATING INSTRUCTIONSP/N 84502 / REV. 03/19/2013NATURAL GAS W255F, W355F, W505F L.P. GAS W256F, W35 ...

    Model & Doc Type: W255F and 24

  • ¢:_2000 Lennox Industries Inc.Dallas, TexasINSTALLATIONINSTRUCTIONSG24M SeriesGAS FURNACETechnicld504,1g7MSureLight_Ignition System _.L_PuF[T_')-bli_ations02/2000Supersedes 503.981M LithoUSARETAIN THESE INSTRUCTIONSFOR FUTURE REFERENCEi:-i:, i I:::::::::::::_::::_:_::::::_:_:::_ _ : : ...

    Model & Doc Type: G24M Series 32

  • Page 1INSTALLATIONINSTRUCTIONSEL195UHE507274-0502/2018Supersedes 06/2017THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in man-uals, be alert to the potential for pers ...

    Model & Doc Type: EL195UHE Elite Series 55

  • Owner’s ManualCONDENSING GAS FURNACENOTE TO INSTALLER:THIS MANUAL MUST BE LEFT WITH THEEQUIPMENT USER.USER: PLEASE READ ALL INSTRUCTIONSIN THE MANUAL AND RETAIN ALLMANUALS FOR FUTURE REFERENCE.FIRE OR EXPLOSION HAZARDFailure to follow warnings could result in personal injury,death, or propert ...

    Model & Doc Type: CONDENSING GAS FURNACE 14

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Nordyne
MGHA Series
8 08/11
2 Alfa Plam
VULKAN S
9 27/12
3 Fire Chief
FC1500
28 01/12
4 Lennox
G50UHi
7 10/04
5 VERDER
CARBOLITE GERO MFS Series
34 03/11
6 Thomas Scientific
5300A20/F48025-TS
44 15/02
7 Payne
PG9MAB
18 0.67 Mb 30/03
8 Lennox
G50UH Series
40 28/03
9 Lyman
Mag 20
7 23/12
10 Yamato
FP 100
65 03/01

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Access HD
DTA1080D
2 18.04.2024
2 Vinotemp
VT-WINEDISP2
13 08.03.2024
3 Brewmatic
1032555
28 23.11.2023
4 Masterflex
P/S 850-3010
52 27.12.2023
5 Pioneer
VSX23TXH - Elite 7.1 Channel Audio/Video Receiver
2 01.12.2023
6 DeLonghi
DD30P
20 08.11.2023
7 Ryobi
HDK19H42
30 26.11.2023
8 NETGEAR
RND2210 - ReadyNAS Duo
2 02.02.2024
9 MedRx
AVANT HIT+
15 20.02.2024
10 Drolet
Baltic
27 0.34 Mb 15.11.2023
Operating Impressions, Questions and Answers: