Carrier Aquazone 50RWS036-360 Installation, Start-up And Service Instructions Manual

Installation, Start-up And Service Instructions Manual for Carrier Aquazone 50RWS036-360 Heat Pump (28 pages)

Specifications:

1237/1237921-aquazone_50rws036360.pdf file (16 Oct 2023)
  • Manufacturer: Carrier
  • Category of Device: Heat Pump
  • Document: Aquazone 50RWS036-360, File Type: PDF Installation, Start-up And Service Instructions Manual
  • Updated: 16-10-2023
  • Count of Pages: 28
Download Aquazone 50RWS036-360 Manual (28 pages)

Read PDF Document Online:

Data: UPD 16th October 2023

Carrier Aquazone 50RWS036-360 Heat Pump PDF Installation, Start-up And Service Instructions Manual (Updated: Monday 16th of October 2023 03:16:10 AM)

Rating: 4.5 (rated by 75 users)

Compatible devices: 38YG (014-060), 42n, APOLLO CONTROL 50HJQ004-016, 50HS, 50HX Guide, 50EQ, 38AUZ, 38AF Series.

Recommended Documentation:

Text Version of Carrier Aquazone 50RWS036-360 Heat Pump Manual (Summary of Contents)

(Ocr-Read of Carrier Aquazone 50RWS036-360 Document (Main Content), UPD: 16 October 2023)
  • 19, 19 ACCESSORY CONNECTIONS — Terminal labeled A on the control is provided to control accessory devices such as water valves, electronic air cleaners, humidifiers, etc. This sig- nal operates with the compressor terminal. See Fig. 8. Refer to the specific unit wiring schematic for details.…

  • 1, Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 111 Catalog No. 535-00094 Printed in U.S.A. Form 50RWS-2SI Pg 1 5-03 Replaces: 50RWS-1SI Book 1 4 Ta b 5 a 5 a Installation, Start-Up, and Service Ins…

  • 25, Carrier Aquazone 50RWS036-360 25 Table 12 — Aquazone™ Deluxe D Control Current LED Status and Alarm Relay Operations LEGEND NOTES: 1. If there is no fault in memory, the Fault LED will flash code 1. 2. Codes will be displayed with a 10-second Fault LED pause. 3. Slow flash is 1 flash every 2 seconds. 4. Fast flash is 2 f…

  • 26, 26 Clean condensers with an inhibited hydrochloric acid solu- tion. The acid can stain hands and clothing, damage concrete, and, without inhibitor, damage steel. Cover surroundings to guard against splashing. Vapors from vent pipe are not harmful, but take care to prevent liquid …

  • 2, 2 Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and the National Electrical Code …

  • 9, 9 GROUND-LOOP APPLICATIONS — Typical ground loop system is shown in Fig. 4. Temperatures between 25 and 110 F and a cooling capacity of 2.25 to 3 gpm of flow per ton is recommended. In addition to complying with any applicable codes, consider the following for system piping: • Piping mate…

DOC-30fea174:

Recommended:
MU-100, J6998, HT-F6530, T96A-EX2

Performance 50VT, RAH-123G, Calibra Cool, JZ100-A1, FTXL20G2V1B
  • EnglishDeutschFrançaisEspañolItalianoNederlandsPortuguesSystem air conditionerOPERATION MANUALRWEYQ10MY1RWEYQ20MY1RWEYQ30MY1Operation manualVRVWII System air conditionerBetriebsanweisungVRVWII System KlimaanlageManuel d’utilisationConditionneur d’air VRVWII SystemManual de operaciónS ...

    Model & Doc Type: VRVWII RWEYQ10MY1 20

  • Service Manual38MBROutdoor Unit Single Zone Ductless SystemSizes 36 to 48TABLE OF CONTENTSPAGESAFETY CONSIDERATIONS 1.........................INTRODUCTION 1...................................MODEL/SERIAL NUMBER NOMENCLATURE 2..........SPECIFICATIONS − OUTDOOR 3..................... ...

    Model & Doc Type: 38MBR series 50

  • Specifications subject to change without notice. TABLE of CONTENTSPAGEINTRODUCTION............................................................................ 1MODEL / SERIAL NUMBER NOMENCLATURES .............. ...

    Model & Doc Type: 38MARBQ12AA1 116

  • Tranquility® Compact Belt Drive (TCH/V) Series Models TCH072 - 120TCV072 - 30060Hz - HFC-410AInstallation, Operation & Maintenance97B0084N01Revised: July 25, 2017Table of ContentsModel Nomenclature 3General Information 4TCH Physical Data (includes unit w/WSE) 6TCV Physical Data (includes un ...

    Model & Doc Type: Tranquility TCH Series 80

Additional Information:
# Brand Model Document Type/File Pages File Size Last Checked
1 Unico
i Series
15 23/01
2 GORMAN-RUPP
13D1-19
28 0.33 Mb 22/03
3 LG
Therma V R32 Gen3
18 24/03
4 Carrier
AQUASnap 30RB
100 27/11
5 Goodman
RHA Series
12 0.66 Mb 25/01
6 Bard
QH243
34 0.88 Mb 12/11
7 Samsung
NH080PHXEA
52 20/02
8 CLIVET
Ceiling & Floor-SM2 IF2 53M Series
120 06/01
9 Gree
LSQWRF35VM/NaA-M
120 07/10
10 Fairland
TurboSilence InverX IXCR36
117 10/10

Popular Right Now:

# Brand Model Document (PDF) Pages Size Check Date
1 Visonic
DUET
4 21.10.2023
2 A.O. Smith
POWER VENT GAS
60 2.02 Mb 01.03.2024
3 NEC
E321
8 10.12.2023
4 Extron electronics
SMP 111
128 13.01.2024
5 Fiat
Bravo sound system
868 17.01.2024
6 Harbor Breeze
RLC52WW5C1R
36 11.10.2023
7 Wyse
R00L
30 4.36 Mb 19.11.2023
8 Texas
EC 2600
42 30.10.2023
9 Pioneer
CD-SR1
8 17.10.2023
10 Craftsman
247.889702
72 19.14 Mb 02.11.2023
Operating Impressions, Questions and Answers: