Specifications:1300/1300909-cs11.pdf file (26 Dec 2023)
|
emmeti CS-11 Thermostat PDF Operation & User’s Manual (Updated: Tuesday 26th of December 2023 05:44:41 PM)
Rating: 4.8 (rated by 68 users)
Compatible devices: 01514228, 900631500, IM-U9132045, CS11, CTUP, CTTS RF, Sintesi Wall, Zona.
Recommended Documentation:
U9310090 M M M M M Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this: In standby mode(when thermostat is turned off), press and hold button and for 5 seconds until RES is shown on LCD. Configure the menu Resetting factory defaults Setting temperature Press or once, you will see set temperature flashing. Use or again to adjust to the temperature you want your room to maintain. Press button to accept and exit. Buttons and LCD display Buttons Press < 5 seconds Press > 5 seconds Turning on/off thermostat Menu button Increase the set value Decrease the set value Lock /unlock buttons Reset to factory settings (when thermostat is turned off) + + Confirm settings The buttons are locked. Displays when heating is active Setback mode Symbol Description Set temperature Set At Sensor selection. This thermostat is a combination model allowing you to choose between 3 different models. (A, AF,F ) A model: air onl y, with built in sensor AF model: air & floo r , with both built in and remote sensor F model: floor only, with remote sensor Press and hold button for 5 seconds. Now you can see Menu 01, to proeceed to other menu, press button again. To exit menu, press button First turn off the thermostat using the on/off button Menu # 01 Switching differential. Calibrate the room temperature. This feature is used to compensate for any difference Calibrate the floor temperature. This feature is used to compensate for any difference Set the floor temperature limit. Select temperature format 06 07 08 09 10 03 04 05 02 Feature Description Factory Default Feature Value 0 °C 40 °C 4°C 10°C 35°C 2°C~ 7°C 10°C~ 20°C 20°C~ 35°C 20 °C ~ 40 °C °C / °F °C A / AF / F A Press or to select The numbers of degree difference before switching. between the displayed room temperature and a thermometer. between the displayed floor temperature and a thermometer. This feature is to protect the floor surface. °C or °F. The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature. 1°C 1°C ~ 5°C -5°C ~ +5°C 0 °C -5°C ~ +5°C Installation and Wiring Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat. Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat. Place the thermostat front half somewhere safe. Make the wiring connections as Screw the thermostat back plate on to the back box. shown in the diagram below. Re-connect the thermostat ribbon cable and clip the CS-11 LCD Digital Setback Thermostat Frost protection. This is to avoid room temperature goes below 5°C. The setback amount( the amount of temperature reduction) on / off off Switched live output 230V ~ 50Hz L N Link terminals 1 to 3 for 230VAC live output Remote sensor for floor temperature control Timeswitch live for operaon of temperature setback mode Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW Tel: 01993 824900 : www.emmeti.co.uk : e: [email protected] This gives you the option to limit the minimum set temperature This gives you the option to limit the maximum set temperature 1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET Wiring Regulations. 2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles. 3. Before commencing work on the installation, the electricity supply must be disconnected. 4. The depth of the back box should be 35mm minimum. WARNING Please Note: one of the following error messages will appear if one of these problems occur: E0, meaning the internal sensor is broken, short-circuit or not working properly. E1, meaning the floor sensor is broken, short-circuit, not connected, or not working properly. Single Zone Multi Zone 1 ErP Class +1% 8 ErP Class +5% two halves together.
TV LC32D1320 Guide, #11JA1G
LC32D1320, 142, aoc/lc32d1320.pdf
Indoor Furnishing Lighting Systems LSBW-15 Reference Book, #G64HE4
Lighting Systems LSBW-15, 2, lightolier/lighting-systems-lsbw-15.pdf
User Guide (XLS SERIES, #CAO478)
XLS SERIES, 8, cerwin-vega/xls-series.pdf
Document (DS-N204, #E5FK92)
DS-N204, 25, hiwatch/ds-n204.pdf
Sena User Guide: X1 PRO (#J82THL)
X1 PRO, 86, sena/x1-pro.pdf
Car Video System PTID-7300 Guidance, #65I4B4
PTID-7300, 20, power-acoustik/ptid-7300.pdf
L20V26 TV - #P1971M
L20V26, 44, zenith/l20v26.pdf
BT Reference Book Cordless Telephone 1250 Classic (#WWH6S4)
1250 Classic, 34, bt/1250-classic.pdf
#F98M4H: PT8-UH User Guide
PT8-UH, 8, york/pt8-uh.pdf
Desktop 130XE Handbook, #Z7MH1J
130XE, 50, atari/130xe.pdf
Instructions ECL Comfort 210 / 310, communication description Table of Contents 1. Introduction ............................................................................................................................................................................2 2. E ...
Model & Doc Type: ECL Comfort 210 53
1User manual ALFA 15 andALFANET 15Cool/Defrost Thermostat.VDH doc. 061283 Version: v2.1 Date: 05-12-2007Software: 043376_ALFA 15/25/35 File: Do061283.wpd Range: -50/+50C per 1C* Function.The ALFA(NET) 15 is a digital thermostat for rail mounting. The thermostat controls the c ...
Model & Doc Type: ALFA 15 4
1SETTING INSTRUCTIONSSETTING THE CLOCKAfter the recessed RESET button has beenpressed the display appears as shown, withthe colon blinking and all the factory pre-setconditions will be present.The clock is a 24 hour type. To change to a 12hour type with am/pm indication press andhold down the &a ...
Model & Doc Type: HP75-1 4
Weatherproof Thermostat Instructions DESCRIPTION SureSTAT thermostats are designed to control automatic ventilation and heating systems. The wide 30° t o 110°F temperature range allows them to be used in many applications. The s ...
Model & Doc Type: T110 2
# | Brand | Model | Document Type/File | Pages | File Size | Last Checked |
---|---|---|---|---|---|---|
1 | Siemens | RDS120 |
7 | 09/11 | ||
2 | jablotron | TP-83IR |
2 | 10/01 | ||
3 | Home Automation | O M N I S T A T RC-90BZ |
20 | 0.27 Mb | 19/02 | |
4 | Lauda | Ecoline E 200 |
55 | 01/12 | ||
5 | Watts | 148WM |
2 | 20/03 | ||
6 | Dansons Group | AcuTron Control Board |
2 | 0.25 Mb | 01/01 | |
7 | Bryant | TSTATBBPB501 |
22 | 0.44 Mb | 24/11 | |
8 | Danfoss | TS715 Si |
2 | 19/04 | ||
9 | Auber | WSD-1501GPH |
14 | 09/12 | ||
10 | DELTA DORE | CALYBOX 110 |
12 | 17/10 |
# | Brand | Model | Document (PDF) | Pages | Size | Check Date |
---|---|---|---|---|---|---|
1 | Heatiator | BH42A |
23 | 7.99 Mb | 08.04.2024 | |
2 | BenQ | DC T1460 |
48 | 05.01.2024 | ||
3 | Lucent Technologies | 6400 Series |
44 | 06.02.2024 | ||
4 | AnyTone | Apollo II |
24 | 16.02.2024 | ||
5 | gourmetmaxx | Z 03640 |
68 | 19.02.2024 | ||
6 | Acura | 2009 RL |
174 | 4.56 Mb | 07.11.2023 | |
7 | Philips | HD9302 |
6 | 13.11.2023 | ||
8 | Makita | 6904VH |
64 | 29.02.2024 | ||
9 | Atlona | AT-HDWP |
14 | 2.7 Mb | 23.03.2024 | |
10 | Panacom | PA-7272 |
20 | 13.04.2024 |